Abstract
Detection of low contrast and very small size objects is of great importance on digital mammography imaging techniques. Hence, when comparing image quality performance for different equipments, it would be desirable to make an objective evaluation primarily based on raw images. In this work we present the results of an image quality performance comparison test for digital mammography systems. Contrast detail curves obtained for raw and filtered images from a CDMAM v3.4 phantom were analyzed. The test resulted in an overall image quality figure index for filtered and raw images of 106.66 and 109.90 respectively for a detection rate threshold of 75%. The largest differences were observed with the small diameter dishes of the phantom.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
CCE (Comisión de las Comunidades Europeas): European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn. European Communities (2006)
Mayo, P., Pascual, A., Rodenas, F., Verdú, G., Campayo, J.M., Villaescusa, J.L.: Desarrollo de Procedimientos de Control de Calidad de Equipos de Radiodiagnóstico Digitales. In: XV Congreso Nacional de Física Médica, Pamplona (2005)
Chevalier, M., Morán, P., Morant, J.J., Miquélez, S., Torres, R.: Protocolo Español de Control de Calidad en Mamografía Digital. Sociedad Española de Física Médica. Edicomplet, Madrid (2008)
Torres, R., Agulla, M., Hernando, I.: Relación Entre Dosis y Calidad de Imagen en Dos Sistemas de Mamografía Digital de Silicio. In: XVII Congreso Nacional de Física Médica, Alicante (2009)
Ayala, R., Linares, R., García, R.: MIQuaEla, Servicio de Radiofísica y Radioprotección. Hospital General Universitario Gregorio Marañón (Madrid), www.ucm.es/info/fismed/Digital_Imaging/MIQuaEla.rar
Rasband, W.: ImageJ, National Institutes of Health (Maryland), rsbweb.nih.gov/ij
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Collado-Chamorro, P., Sanz-Freire, C., Gómez-Amez, J., Vázquez-Galiñanes, A., Lopo-Casqueiro, N., González-De La Puente, M. (2010). Contrast Detail Curves on Digital Mammography: Performance Comparison of Raw and Filtered Images. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_41
Download citation
DOI: https://doi.org/10.1007/978-3-642-13666-5_41
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13665-8
Online ISBN: 978-3-642-13666-5
eBook Packages: Computer ScienceComputer Science (R0)