Abstract
Volumetric breast composition measurements generally require accurate imaging physics data. In this paper we describe a new method (VolparaTM) that uses relative (as opposed to absolute) physics modeling together with additional information derived from the image to substantially reduce the dependence on imaging physics data. Results on 2,217 GE digital images, from a diversity of sites, show encouraging agreement with MRI data, as well as robustness to noise and errors in the imaging physics data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Boyd, N., Guo, H., Martin, L., Sun, L., Stone, J., Fishell, E., Jong, R., Hislop, G., Chiarelli, A., Minkin, S., Yaffe, M.: Mammographic density and the risk and detection of breast cancer. New England Journal of Medicine 356(3), 227–236 (2007)
Boyd, N., Lockwood, G., Byng, J., Tritchler, D., Yaffe, M.: Mammographic densities and breast cancer risk. Cancer Epidemiol. Biomarkers Prev. 7, 1133–1144 (1998)
Harvey, J., Bovbjerg, V.: Quantitative assessment of mammographic breast density: relationships with breast cancer risk. Radiology 230, 29–41 (2004)
Wolfe, J.: Breast patterns as an index of risk of developing breast cancer. Am. J. Roentgenol. 126, 1130–1139 (1976)
Wolfe, J.: Risk for breast cancer development determined by mammographic parenchymal patterns. Cancer 37, 2486–2492 (1976)
Saftlas, A., Szklo, M.: Mammographic parenchymal patterns and breast cancer risk. Epidemiol. Rev. 9, 146–174 (1987)
Goodwin, P., Boyd, N.: Mammographic parenchymal patterns and breast cancer risk: a critical appraisal of the evidence. Am. J. Epidemiol. 127, 1097–1108 (1988)
Carney, P., Miglioretti, D., Yankaskas, B., Kerlikowske, K., Rosenberg, R., Rutter, C., Geller, B., Abraham, L., Taplin, S., Dignan, M., Cutter, G., Ballard-Barbash, R.: Individual and combined effects of age, breast density, and hormonal replacement therapy use on the accuracy of screening mammography. Ann. Intern. Med. 138, 168–175 (2003)
Buist, D., Porter, P., Lehman, C., Taplin, S., White, E.: Factors contributing to mammography failure in women aged 40-49 years. J. Nat. Cancer. Inst. 96, 1432–1440 (2004)
Saftlas, A., Hoover, R., Brinton, L., Szlo, M., Olson, D., Salane, M., Wolfe, J.: Mammographic densities and risk of breast cancer. Cancer 67, 2833–2838 (1991)
Wolfe, J., Saftlas, A., Salane, M.: Mammographic parenchymal patterns and quantitative evaluation of mammographic densities: a case-control study. Am. J. Roentgenol. 148, 1087–1092 (1987)
American College of Radiology, Breast imaging reporting and data systems (BIRADS). American College of Radiology, Reston, Va (1993)
Martin, et al.: Mammographic density measured with quantitative computer-aided method: comparison with radiologists’ estimates and BI-RADS categories. Radiology 240(3), 656 (2006)
Nicholson, B., LoRusso, A., Smolkin, M., Bovbjerg, V., Petroni, G., Harvey, J.: Accuracy of assigned BIRADS breast density category definitions. Academic Radiology 13(9), 1143–1149
Diffey, J., Hufton, A., Astley, S.: A new step-wedge for volumetric measurement of mammographic density. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 1–9. Springer, Heidelberg (2006)
van Engeland, S., Snoeren, P., Huisman, H., Boetes, C., Karssemeijer, N.: Volumetric breast density estimation from full-field digital mammograms. IEEE Medical Imaging 25(3), 273–282 (2006)
Highnam, R., Brady, M.: Mammographic Image Analysis. Kluwer Academic, Dordrecht (1999)
Shepherd, J.: Automated volumetric density. In: 3rd International Workshop on Breast Density (2008)
Tromans, C., Brady, M., Van de Sompel, D., Lorenzon, M., Bazzocchi, M., Zuiani, C.: Progress toward a quantitative scale for describing radiodensity in mammographic images. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 553–560. Springer, Heidelberg (2008)
Pawluczyk, O., Yaffe, M., Boyd, N., Jong, R.: Volumetric method for estimation of breast density on digitized screen-film mammograms. Medical Physics 30(3), 352 (2003)
McCormack, V., Highnam, R., Perry, N., dos Santos Silva, I.: Comparison of a new and existing method of mammographic density measurement. Cancer, Epidemiol. Biomarkers Prev. 16(16), 1148–1154 (2007)
Yaffe, M.: Measurement of mammographic density. Breast Cancer Research 10, 209 (2008)
Kovesi, P.: Image Features from Phase Congruency, Videre. MIT Press, Cambridge (1999)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Highnam, R., Brady, S.M., Yaffe, M.J., Karssemeijer, N., Harvey, J. (2010). Robust Breast Composition Measurement - VolparaTM . In: MartÃ, J., Oliver, A., Freixenet, J., MartÃ, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_46
Download citation
DOI: https://doi.org/10.1007/978-3-642-13666-5_46
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13665-8
Online ISBN: 978-3-642-13666-5
eBook Packages: Computer ScienceComputer Science (R0)