Abstract
We investigated the link between the results from daily quality control (QC) data, on the one hand, and from successive half-yearly medical physics QC visits on the other hand. To do so, criteria defining ‘unchanged results’ were set for both the daily QC data and the half-yearly QC results. Out of the results of 181 QC visits and daily QC at the time of the QC visit, we found that systems that showed little or no deviation in daily constancy performance were likely to show basically unchanged results in the half-yearly medical physics test. The specificity of the daily QC data for a change in results at QC visits was 93% for the dose and SDNR test and 88% for a change in contrast threshold values. Daily QC data could be used to prioritize the work load of the medical physicist.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., von Karsa, L., Puthaar, E. (eds.): European protocol for the quality control of the physical and technical aspects of mammography screening. Office for Official Publications of the European Communities (2006)
Jacobs, J., Lemmens, K., Nens, J., Michielsen, K., Marchal, G., Bosmans, H.: One year of experience with remote quality control of digital mammography systems in the Flemish breast cancer screening program. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 703–710. Springer, Heidelberg (2008)
Jacobs, J., Rogge, F., Kotre, J., Marchal, G., Bosmans, H.: Preliminary validation of a new variable pattern for daily quality control of medical image display devices. Med. Phys. 34(7), 2744–2758 (2007)
Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6142, pp. 614206-1–614206-13 (2006)
Samei, E., Badano, A., Chakraborty, D., Compton, K., Cornelius, C., Corrigan, K., Flynn, M.J., Hemminger, B., Hangiandreou, N., Johnson, J., Moxley-Stevens, D.M., Pavlicek, W., Roehrig, H., Rutz, L., Shepard, J., Uzenoff, R.A., Wang, J., Willis, C.E.: AAPM TG18. Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med. Phys. 32(4), 1205–1225 (2005)
Digital Imaging and Communications in Medicine (DICOM) part 14: grayscale standard display function, NEMA PS 3.14, Rosslyn, VA: National Electrical Manufacturers Association (2000)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Michielsen, K., Jacobs, J., Marshall, N., Bosmans, H. (2010). Analysis of Mammography Quality Control Results: Evidence for a Change in Test Frequency?. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_50
Download citation
DOI: https://doi.org/10.1007/978-3-642-13666-5_50
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13665-8
Online ISBN: 978-3-642-13666-5
eBook Packages: Computer ScienceComputer Science (R0)