Analysis of Geometric Accuracy in Digital Breast Tomosynthesis Reconstruction

  • Conference paper
Digital Mammography (IWDM 2010)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 6136))

Included in the following conference series:

Abstract

The geometric accuracy of a digital breast tomosynthesis (DBT) reconstruction algorithm was assessed using an anthropomorphic software breast phantom with simulated fiducial markers. The locations of the fiducial markers were measured from supersampled images reconstructed to sub-pixel precision. The measured locations were compared with the known ground truth positions of the simulated markers. The fiducial markers simulate small, attenuating objects within the software phantom. Using reconstructed images with resolution of 0.115 mm, and a total of twelve fiducial markers at three different depths, we determined an average difference of 0.105 mm (st. dev. 0.086 mm) between the estimated and true marker locations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Hu, Y.-H., Zhao, B., Zhao., W.: Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach. Medica Physics 35, 5242–5252 (2008)

    Article  Google Scholar 

  2. Wang, X., Mainprize, J.G., Kempstone, M.P., Mawdsley, G.E., Yaffe, M.J.: Digital Breast Tomosynthesis Geometry Calibration. In: SPIE Medical Imaging 2007: Physics in Medical Imaging (2007)

    Google Scholar 

  3. CIRS Tissue Simulation and Phantom Technology: Mammographic Accreditation Phantom, http://www.cirsinc.com/015_mammo.html (accessed on January 17, 2009)

  4. Bakic, P.R., Albert, M., Brzakovic, D., Maidment, A.D.A.: Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation. Medical Physics 29, 2131–2139 (2002)

    Article  Google Scholar 

  5. Zhang, C., Bakic, P.R., Maidment, A.D.A.: Development of an Anthropomorphic Breast Software Phantom Based on Region Growing Algorithm. In: Visualization, Image-guided procedures, and Modeling, Proc. SPIE, vol. 6918 (2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bakic, P.R., Ringer, P., Kuo, J., Ng, S., Maidment, A.D.A. (2010). Analysis of Geometric Accuracy in Digital Breast Tomosynthesis Reconstruction. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_9

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13666-5_9

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13665-8

  • Online ISBN: 978-3-642-13666-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics