Abstract
Cardiac Motion artifacts in PET are a well known problem. The heart undergoes two types of motion, the motion due to respiratory displacement and the motion due to cardiac contraction. These movements lead to blurring of data and to inaccuracies in the quantification. In this study a continuity equation based optical flow method is presented and results on 3D PET patient datasets for cardiac motion correction are presented. The method was evaluated with respect to three criteria: correlation between the images, myocardial thickness and the blood pool activity curves. The results showed that the method was successful in motion correcting the data with high precision.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Vandenberghe, S., D’Asseler, Y., Van de Walle, R., Kauppinen, T., Koole, M., Bouwens, L., Van Laere, K., Lemahieu, I., Dierckx, R.A.: Iterative reconstruction algorithms in nuclear medicine. Comput. Med. Imaging Graph. 25(2), 105–111 (2001)
Erdi, Y.E., Nehmeh, S.A., Pan, T., Pevsner, A., Rosenzweig, K.E., Mageras, G., Yorke, E.D., Schoder, H., Hsiao, W., Squire, O.D., Vernon, P., Ashman, J.B., Mostafavi, H., Larson, S.M., Humm, J.L.: The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. J. Nucl. Med. 45(8), 1287–1292 (2004)
Shepp, L.A., Vardi, Y.: Maximum Likelihood Reconstruction for Emission Tomography. IEEE Trans. Med. Imag. 1(2), 113–122 (1982)
Osman, M.M., Cohade, C., Nakamoto, Y., Marshall, L.T., Leal, J.P., Wahl, R.L.: Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. J. Nucl. Med. 44(2), 240–243 (2003)
Nakamoto, Y., Chin, B.B., Cohade, C., Osman, M., Tatsumi, M., Wahl, R.L.: PET/CT: artifacts caused by bowel motion. Nucl. Med. Commun. 25(3), 221–225 (2004)
Dawood, M., Büther, F., Lang, N., Schober, O., Schäfers, K.P.: Respiratory gating in positron emission tomography: A quantitative comparision of different gating schemes. Medical Physics 34, 3067–3076 (2007)
Qiao, F., Pan, T., Clark, J.W., Mawlawi, O.R.: A motion-incorporated reconstruction method for gated PET studies. Phys. Med. Biol. 51(15), 3769–3783 (2006)
Mair, B.A., Gilland, D.R., Sun, J.: Estimation of images and nonrigid deformations in gated emission CT. IEEE Trans. Med. Imaging 25(9), 1130–1144 (2006)
Lamare, F., Carbayo, M.J.L., Cresson, T., Kontaxakis, G., Santos, A., Rest, C.C.L., Reader, A.J., Visvikis, D.: List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations. Phys. Med. Biol. 52, 5187–5204 (2007)
Klein, G.J., Reutter, B.W., Huesman, R.H.: Non-rigid summing of gated PET via optical flow. IEEE Transactions on Nuclear Science 44(4), 1509–1512 (1997)
Gilland, D.R., Mair, B.A., Bowsher, J.E., Jaszczak, R.J.: Simultaneous reconstruction and motion estimation for gated cardiac ECT. IEEE Transactions on Nuclear Science 49(5), 2344–2349 (2002)
Dawood, M., Büther, F., Jiang, X., Schäfers, K.P.: Respiratory Motion Correction in 3D PET Data with Advanced Optical Flow Algorithms. IEEE Trans. Med. Imaging 27(8), 1164–1175 (2008)
Corpetti, T., Heitz, D., Arroyo, G., Mémin, E., Santa-Cruz, A.: Fluid experimental flow estimation based on an optical-flow scheme. Experiments in Fluids 40, 80–97 (2006)
Segars, W.P.: Development and application of the new dynamic NURBS-based cardiac-torso (NCAT) phantom, in Biomedical Engineering. Dissertation, University of North Carolina (2001)
Dawood, M., Lang, N., Jiang, X., Schäfers, K.P.: Lung motion correction on respiratory gated 3-D PET/CT images. IEEE Trans. Med. Imaging 25(4), 476–485 (2006)
Bruhn, A., Weickert, J., Schnörr, C.: Lucas/Kanade meets Horn/Schunck: Combining local and global optic flow methods. International Journal of Computer Vision 61(3), 211–231 (2005)
Horn, B., Schunck, B.: Determining optical flow. Artificial Intelligence 17, 185–203 (1981)
Vitale, G.D., de Kemp, R.A., Ruddy, T.D., Williams, K., Beanlands, R.S.: Myocardial glucose utilization and optimization of (18)F-FDG PET imaging in patients with non-insulin-dependent diabetes mellitus, coronary artery disease, and left ventricular dysfunction. J. Nucl. Med. 42(12), 1730–1736 (2001)
Erdi, Y.E., Nehmeh, S.A., Mulnix, T., Humm, J.L., Watson, C.C.: PET performance measurements for an LSO-based combined PET/CT scanner using the national electrical manufacturers association nu 2-2001 standard. J. Nucl. Med. 45(5), 813–821 (2004)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Dawood, M. et al. (2010). A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data. In: Liao, H., Edwards, P.J."., Pan, X., Fan, Y., Yang, GZ. (eds) Medical Imaging and Augmented Reality. MIAR 2010. Lecture Notes in Computer Science, vol 6326. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-15699-1_10
Download citation
DOI: https://doi.org/10.1007/978-3-642-15699-1_10
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-15698-4
Online ISBN: 978-3-642-15699-1
eBook Packages: Computer ScienceComputer Science (R0)