Abstract
X-ray fluoroscopically guided cardiac ablation procedures are commonly carried out for the treatment of cardiac arrhythmias, such as atrial fibrillation (AF). X-ray images have poor soft tissue contrast and, for this reason, overlay of a 3D roadmap derived from pre-procedural volumetric image data can be used to add anatomical information. It is a requirement to determine and record the 3D positions of the ablation catheter tip in the 3D road map during AF ablation. This feature can be used as a guidance and post-procedure analysis tool. The 3D positions of the catheter tip can be calculated from biplane X-ray images and mapped to the 3D roadmap. However, the registration between the 3D roadmap and the 2D X-ray data can be compromised by patient respiratory and cardiac motions. As the coronary sinus (CS) catheter is not routinely altered during the procedure, tracking the CS catheter in real-time can be used as means of motion correction to improve the accuracy of registration between live X-ray images and a 3D roadmap. To achieve a fast and automatic ablation point tagging system from biplane images, we developed a novel tracking method for real-time simultaneous detection of the ablation catheter and the CS catheter from fluoroscopic X-ray images. We tested our tracking method on 1083 fluoroscopy frames from 16 patients and achieved a success rate of 97.5% and an average 2D tracking error of 0.5 mm ± 0.3 mm. In order to achieve tagging using a mono-plane X-ray image system, we proposed a novel motion gating method to select a pair of images from two short image sequences acquired from two different views. Both respiratory and cardiac motion phases are matched by selecting the pair of images with the minimum reconstruction error of the CS catheter electrodes. Finally, the 3D position of the ablation catheter tip was calculated using the epipolar constraint from the multiview images. We validated our automatic ablation point tagging strategy by computing the reconstruction error of the ablation catheter tip and achieved an error of 1.1 mm ± 0.5 mm.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Rhode, K.S., Hill, D.L.G., Edwards, P.J., Hipwell, J., Rueckert, D., Sanchez-Ortiz, G., Hegde, S., Rahunathan, V., Razavi, R.: Registration and tracking to integrate X-ray and MR images in an XMR facility. IEEE Transactions on Medical Imaging 24(11), 810–815 (2003)
Hertrich, P.: Practical Radiography - Principles and Applications, 1st edn. Publicis Corporate Publishing, Erlangen (2005)
Pruemmer, M., Hornegger, J., Lauritsch, G., Wigstrom, L., Girard-Hughes, E., Fahrig, R.: Cardiac C-arm CT: a unified framework for motion estimation and dynamic CT. IEEE Trans. Med. Imaging 28(11), 1836–1849 (2009)
Orlov, M.V., Hoffmeister, P., Chaudhry, G.M., Almasry, I., Gijsbers, G.H., Swack, T., Haffajee, C.I.: Three-dimensional rotational angiography of the left atrium and esophagus–A virtual computed tomography scan in the electrophysiology lab. Heart Rhythm 4(1), 37–43 (2007)
Tang, M., Kriatselis, C., Ye, G., Nedios, S., Roser, M., Solowjowa, N., Fleck, E., Gerds-Li, J.H.: Reconstructing and registering three-dimensional rotational angiogram of left atrium during ablation of atrial fibrillation. Pacing Clin. Electrophysiol. 32(11), 1407–1416 (2009)
Knecht, S., Skali, H., O’Neill, M.D., Wright, M., Matsuo, S., Chaudhry, G.M., Haffajee, C.I., Nault, I., Gijsbers, G.H., Sacher, F., Laurent, F., Montaudon, M., Corneloup, O., Hocini, M., Haïssaguerre, M., Orlov, M.V., Jaïs, P.: Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia. Europace 10(8), 931–938 (2008)
Brooks, A.G., Wilson, L., Kuklik, P., Stiles, M.K., John, B., Shashidhar, D.H., Lau, D.H., Roberts-Thomson, R.L., Wong, C.X., Young, G.D., Sanders, P.: Image integration using NavX fusion: Initial experience and validation. Heart Rhythm 5(4), 526–535 (2008)
Franken, E., Rongen, P., van Almsick, M., ter Haar Romeny, B.M.: Detection of Electrophysiology Catheters in Noisy Fluoroscopy Images. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol. 4191, pp. 25–32. Springer, Heidelberg (2006)
King, A.P., Boubertakh, R., Rhode, K.S., Ma, Y.L., Chinchapatnam, P., Gao, G., Tangcharoen, T., Ginks, M., Hawkes, D.J., Razavi, R.S., Schaeffter, T.: A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med. Image. Anal. 13(3), 419–431 (2009)
Shechter, G., Shechter, B., Resar, J.R., Beyar, R.: Prospective motion correction of X-ray images for coronary interventions. IEEE Transactions on Medical Imaging 24(4), 441–450 (2005)
Sundar, H., Khamene, A., Yatziv, L., Xu, C.: Automatic Image-Based Cardiac and Respiratory Cycle Synchronization and Gating of Image Sequences. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009. LNCS, vol. 5762, pp. 381–388. Springer, Heidelberg (2009)
Brost, A., Liao, R., Strobel, N., Hornegger, J.: Respiratory motion compensation by model-based catheter tracking during EP procedures. Med. Image. Anal. 14(5), 695–706 (2010)
Ma, Y., King, A.P., Gogin, N., Rinaldi, C.A., Gill, J., Razavi, R., Rhode, K.S.: Real-time respiratory motion correction for cardiac electrophysiology procedures using image-based coronary sinus catheter tracking. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010. LNCS, vol. 6361, pp. 391–399. Springer, Heidelberg (2010)
Hoffman, K., Sen, A., Lan, L., Metz, C., Chua, K., Williams, B., Esthappen, J., Fiebich, M., Mazzucco, M., Doi, K.: Determination of 3-D vessel trees from biplane images from coronary angiography. Computer. Assisted Radiology Surgery, 162–165 (1997)
Tony, L.: Detecting salient blob-like image structures and their scales with a scale-space primal sketch: a Method for focus-of-attention. International Journal of Computer Vision 11(3), 283–318 (1993)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Ma, Y. et al. (2011). Image-Based Automatic Ablation Point Tagging System with Motion Correction for Cardiac Ablation Procedures. In: Taylor, R.H., Yang, GZ. (eds) Information Processing in Computer-Assisted Interventions. IPCAI 2011. Lecture Notes in Computer Science, vol 6689. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21504-9_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-21504-9_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-21503-2
Online ISBN: 978-3-642-21504-9
eBook Packages: Computer ScienceComputer Science (R0)