Skip to main content

Modified Eulers Elastica Inpainting for Metal Artifact Reduction in CT

  • Chapter
  • First Online:
Bildverarbeitung für die Medizin 2012

Part of the book series: Informatik aktuell ((INFORMAT))

Abstract

In computed tomography (CT) metal causes strong streak artifacts in the reconstructed images, which may hinder the correct diagnosis of patients. In this work, metal artifacts are reduced using the modified Eulers elastica and curvature based sinogram inpainting (EECSI). The inconsistent data is deleted from the sinogram and replaced by a two-dimensional interpolation strategy based on the surrounding data information using partial differential equations. The inpainting domain is defined by a binary mask that is calculated using a thresholding method in the preliminary reconstructed image with a following forward projection of the metal-only image. Here, the EECSI is modified by a statistic weighting function that regulates the time step size depending on the probability of a gray value. Additionally, the connectivity principle is strengthened by applying a different strategy in the numerical implementation compared to prior methods. The measurements are realized on a Philips Tomoscan M/EG scanner using a torso phantom with the physical properties of an average male torso, suitable for medical experiments. For evaluation, the results are compared to the ones achieved by using the original EECSI and the classically used one-dimensional linear interpolation method. It is demonstrated that the performed modifications result in a better metal artifact suppression.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 99.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 129.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987; p. 576–7.

    Google Scholar 

  2. Oehler M, Buzug TM. An image inpainting based surrogate data strategy for metal artifact reduction in CT images. In: Proc IFMBE; 2008. p. 651–4.

    Google Scholar 

  3. Oehler M, Buzug TM. Evaluation of surrogate data quality in sinogram-based CT metal artifact reduction. In: Proc SPIE; 2008. p. 1–10.

    Google Scholar 

  4. Chan T, Kang SH, Shen J. Euler‘s elastica and curvature based inpaintings. SIAM J Appl Math. 2002; p. 564–92.

    Google Scholar 

  5. Gu J, Zhang L, Yu G, et al. Metal artifact reduction in CT images through Euler‘s elastica and curvature based sinogram inpainting. In: Proc SPIE. vol. 6144; 2006. p. 65.

    Google Scholar 

  6. Bertalmio M, Sapira G, Caselles V, et al. Image inpainting. In: Proc SIGGRAPH; 2000. p. 417–24.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Julia Hamer .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Hamer, J., Kratz, B., Müller, J., Buzug, T.M. (2012). Modified Eulers Elastica Inpainting for Metal Artifact Reduction in CT. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2012. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-28502-8_54

Download citation

Publish with us

Policies and ethics