Radio-frequency (RF) catheter ablation has become the standard treatment of atrial fibrillation if pharmacotherapy fails. As an alternative to traditional RF standard ablation catheters, single-shot devices have received more and more interest. One group of these devices are cryo-balloon catheters. Such catheters are designed to electrically isolate a pulmonary vein (PV) with only a few applications, ideally only one. Whereas standard radio-frequency ablation catheters operate point by point, cryo-balloon devices need to be positioned antrally to the pulmonary vein ostium before freezing. If a good seal can be achieved far enough outside of the pulmonary veins, the cryo-balloon is an effective and safe ablation device. The catheters are inserted through a transseptal sheath and are inflated using liquid nitrogen. Single-shot devices, when used successfully, promise a reduction of procedure time and Xray exposure. Single-shot devices based on ablation energies other than RF, may not carry electrodes or electromagnetic sensors. This makes it difficult to visualize them using standard EP mapping systems. As a result, fluoroscopic imaging is needed. Unfortunately, the inflated balloon may be difficult to see under X-ray. To improve this situation, we propose a new method that tracks and enhances the visualization of a cryo-balloon catheter under fluoroscopic imaging. The method involves a 2-D template of the cryo-balloon that is manually initialized and then tracks the balloon device during live X-ray imaging. To improve visualization, a 2-D ellipse is overlaid onto the fluoroscopic imaging to highlight the position of the balloon catheter. The tracking error was calculated as the distance between the tracked catheter template and the manually segmented catheter. Our method achieved 2-D tracking error of 0.60 mm ± 0.32 mm.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Calkins H, Brugada J, Packer D, et al. Expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. Europace. 2007; p. 335–79.
Sra J, Narayan G, Krum D, et al. Computed tomography-fluoroscopy image integration-guided catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2007; p. 409–14.
De Buck S, Maes F, Ector J, et al. An augmented reality system for patient-specific guidance of cardiac catheter ablation procedures. IEEE Trans Med Imaging. 2005; p. 1512–24.
Koller M, Schumacher B. cryoballoon ablation of paroxysmal atrial fibrillation: bigger is better and simpler is better. Eur Heart J. 2009;30(6):636–7.
Schenderlein M, Rasche V, Dietmayer K. Three-dimensional catheter tip tracking from asynchronous biplane x-ray image sequences using non-linear state filtering. Proc BVM. 2011; p. 234–8.
Schenderlein M, Dietmayer K. Image-based catheter tip tracking during cardiac ablation therapy. Methods Inform Med. 2010; p. 1–5.
Brost A, Liao R, Strobel N, et al. Respiratory motion compensation by modelbased catheter tracking during EP procedures. Med Image Anal. 2010; p. 695–706.
Brost A, Wimmer A, Liao R, et al. Constrained 2-D/3-D registration for motion compensation in AFib ablation procedures. In: Information Processing in Computer-Assisted Interventions. Springer Berlin / Heidelberg; 2011. p. 133–44.
Brost A, Bourier F, Kleinoeder A, et al. AFiT - Atrial fibrillation ablation planning tool. In: Proc VMV; 2011. p. 223–30.
Wu W, Chen T, Barbu A, et al. Learning-based hypothesis fusion for robust catheter tracking in 2D X-ray fluoroscopy. In: Proc IEEE CVPR; 2011. p. 1097–104.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Kurzendorfer, T. et al. (2012). Cryo-Balloon Catheter Tracking in Atrial Fibrillation Ablation Procedures. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2012. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-28502-8_67
Download citation
DOI: https://doi.org/10.1007/978-3-642-28502-8_67
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-28501-1
Online ISBN: 978-3-642-28502-8
eBook Packages: Computer Science and Engineering (German Language)