Abstract
Long acquisition times of several seconds lead to image artifacts in cardiac C-arm CT. These artifacts are mostly caused by respiratory motion. In order to improve image quality, it is important to accurately estimate the breathing motion that occurred during image acquisition. It has been shown that diaphragm motion is correlated to the respiration-induced motion of the heart. We describe the development of a method that is able to accurately track the contour of the diaphragm in projection space using a 2D quadratic curve model of the diaphragm to simplify the process. In order to provide robust and stable tracking, additional constraints based on prior knowledge of the projection geometry and human anatomy are introduced. Results show that the tracking is very accurate. A mean model error per pixel of 0.93 ± 0.44 pixels for the left and 0.79 ± 0.19 pixels for the right hemidiaphragm was observed. The diaphragm top is tracked with an even lower error of only 0.75 ± 0.84 pixels for the left and 0.45 ± 056 pixels for the right hemidiaphragm respectively.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Jahnke C, Paetsch I, Achenbach S, et al. Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use. Radiology. 2006;239:71–8.
Wiesner S, Yaniv Z. Respiratory signal generation for retrospective gating of cone- beam CT images. Proc SPIE. 2008;6918:71.
Marchant TE, Price GJ, Matuszewiski BJ, et al. Reduction of motion artefacts in on-board cone beam CT by warping of projection images. Br J Radiol. 2011;84:251– 64.
Wang Y, Riederer S, Ehman R. Respiratory motion of the heart: kinematics and the implications for spatial resolution in coronary imaging. Magn Reson Med. 1995;33:716–19.
Sonke JJ, Zijp L, Remeijer P, et al. Respiratory correlated cone beam CT. Med Phys. 2005;32:1176–86.
Canny FJ. A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell. 1986;8(6):679–98.
Fischler MA, Bolles RC. Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM. 1981;24:381–95.
Segars WP, Mahesh M, Beck TJ, et al. Realistic CT simulation using the 4D XCAT phantom. Med Phys. 2008;35(8):3800–8.
Schwemmer C, Prummer M, Daum V, et al. High-Density object removal from projection images using low-frequency-based object masking. Proc BVM. 2010; p. 365–9.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Bögel, M., Maier, A., Hofmann, H.G., Hornegger, J., Fahrig, R. (2012). Diaphragm Tracking in Cardiac C-Arm Projection Data. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2012. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-28502-8_8
Download citation
DOI: https://doi.org/10.1007/978-3-642-28502-8_8
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-28501-1
Online ISBN: 978-3-642-28502-8
eBook Packages: Computer Science and Engineering (German Language)