Converting One Set of Mammograms to Simulate a Range of Detector Imaging Characteristics for Observer Studies

  • Conference paper
Breast Imaging (IWDM 2012)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 7361))

Included in the following conference series:

  • 2729 Accesses

Abstract

A methodology for adjusting mammographic images taken on a given imaging system to simulate their appearance if taken on a different system for use in observer studies is presented. The process involves adjusting the image sharpness and noise, which takes into account the detector, breast thickness, and beam quality. The method has been tested by converting images acquired using an a-Se detector of a CDMAM test object and ‘Rachel’ anthropomorphic breast phantom. They were degraded to appear as if acquired using a computed radiography (CR) detector. Good agreement was achieved in the resulting threshold gold thickness for the simulated CR images with measured real values for CDMAM images. Power spectra comparisons of real and simulated images of the ‘Rachel’ phantom agree with an average difference of 4%. This tool in conjunction with observer studies can be used to understand the effects of the detector characteristics on cancer detection in mammography.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Mackenzie, A., Dance, D.R., Workman, A., Yip, M., Wells, K., Young, K.C.: Development and validation of a method for converting images to appear with noise and sharpness characteristics of a different detector and X-ray system. Med. Phys. 39, 2721–2734 (2012)

    Article  Google Scholar 

  2. Boone, J.M., Fewell, T.R., Jennings, R.J.: Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med. Phys. 24, 1863–1874 (1997)

    Article  Google Scholar 

  3. Berger, M.J., Hubbell, J.H., Seltzer, S.M., Chang, J., Coursey, J.S., et al.: XCOM: Photon cross sections database. NIST Standard Reference Database 8, 87-3597 (1998)

    Google Scholar 

  4. Dance, D.R., Skinner, C.L., Young, K.C., Beckett, J.R., Kotre, C.J.: Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys. Med. Biol. 45, 3225–3240 (2000)

    Article  Google Scholar 

  5. Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., et al.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6913, pp. 69131C-1–69131C-11 (2008)

    Google Scholar 

  6. Warren, L.M., Mackenzie, A., Cooke, J., Given-Wilson, R., Wallis, M.G., et al.: Mammographic calcification cluster detection and threshold gold thickness measurements. In: Proc. SPIE, vol. 8313, p. 83130J (2012)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Mackenzie, A., Dance, D.R., Diaz, O., Barnard, A., Young, K.C. (2012). Converting One Set of Mammograms to Simulate a Range of Detector Imaging Characteristics for Observer Studies. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_51

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-31271-7_51

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-31270-0

  • Online ISBN: 978-3-642-31271-7

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics