Skip to main content

Application of a Dynamic 4D Anthropomorphic Breast Phantom in Contrast-Based Imaging System Optimization: Dual-Energy or Temporal Subtraction?

  • Conference paper
Breast Imaging (IWDM 2012)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 7361))

Included in the following conference series:

  • 2768 Accesses

Abstract

We previously developed a dynamic 4D anthropomorphic breast phantom, which can be used to optimize contrast-based breast imaging systems, accounting for patient variability and contrast kinetics [1]. In this study we aim to compare the performance of contrast-enhanced mammographic and tomosynthesis imaging protocols followed by temporal subtraction and dual-energy subtraction, qualitatively and quantitatively across a couple of patient models. Signal-difference-to-noise ratio (SDNR) is measured for the six paradigms of contrast enhanced, temporally subtracted, and dual-energy subtracted mammography and tomosynthesis and compared. The results show how the performance is more dependent on the breast model in mammography than in tomosynthesis. Also, it is observed that dual-energy subtraction can be beneficial in mammography, whereas it is not advantageous in tomosynthesis. Lastly, the results suggest that temporal subtraction in general outperforms dual-energy subtraction.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Kiarashi, N., Lin, Y., Segars, W.P., Ghate, S.V., Ikejimba, L., Chen, B., Lo, J.Y., Dobbins III, J.T., Nolte, L.W., Samei, E.: Development of a Dynamic 4D Anthropomorphic Breast Phantom for Contrast-based Breast Imaging. In: Proc. SPIE, vol. 8313, pp. 0C1–0C7 (2012)

    Google Scholar 

  2. Chen, B., Shorey, J., Saunders, R.S., Richard, S., Thompson, J., Nolte, L.W., Samei, E.: An anthropomorphic breast model for breast imaging simulation and optimization. Acad. Radiol. 18(5), 536–546 (2011)

    Article  Google Scholar 

  3. Li, C.M., Segars, W.P., Lo, J.Y., Dobbins III, J.T., Veress, A.I., Boone, J.M.: Three-dimensional computer generated breast phantom based on empirical data. In: Proc. SPIE, vol. 6913, pp. 14.1–14.8 (2008)

    Google Scholar 

  4. Li, C.M., Segars, W.P., Dobbins III, J.T., Tourassi, G.D., Boone, J.M.: Methodology for generating a 3D computerized breast phantom from empirical data. Med. Phys. 36(7), 3122–3131 (2009)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Kiarashi, N., Ghate, S.V., Lo, J.Y., Nolte, L.W., Samei, E. (2012). Application of a Dynamic 4D Anthropomorphic Breast Phantom in Contrast-Based Imaging System Optimization: Dual-Energy or Temporal Subtraction?. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_85

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-31271-7_85

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-31270-0

  • Online ISBN: 978-3-642-31271-7

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics