Abstract
We propose a methodology to register medical images of carotid arteries from tracked freehand sweep B-Mode ultrasound (US) and magnetic resonance imaging (MRI) acquisitions. Successful registration of US and MR images will allow a multimodal analysis of atherosclerotic plaque in the carotid artery. The main challenge is the difference in the positions of the patient’s neck during the examinations. While in MRI the patient’s neck remains in a natural position, in US the neck is slightly bent and rotated. Moreover, the image characteristics of US and MRI around the carotid artery are very different. Our technique uses the estimated centerlines of the common, internal and external carotid arteries in each modality as landmarks for registration. For US, we used an algorithm based on a rough lumen segmentation obtained by robust ellipse fitting to estimate the lumen centerline. In MRI, we extract the centerline using a minimum cost path approach in which the cost is defined by medialness and an intensity based similarity term. The two centerlines are aligned by an iterative closest point (ICP) algorithm, using rigid and thin-plate spline transformation models. The resulting point correspondences are used as a soft constraint in a subsequent intensity-based registration, optimizing a weighted sum of mutual information between the US and MRI and the Euclidean distance between corresponding points. Rigid and B-spline transformation models were used in this stage. Experiments were performed on datasets from five healthy volunteers. We compared different registration approaches, in order to evaluate the necessity of each step, and to establish the optimum algorithm configuration. For the validation, we used the Dice similarity index to measure the overlap between lumen segmentations in US and MRI.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
McCarthy, M.J., Loftus, I.M., Thompson, M.M., Jones, L., London, N.J.M., Bell, P.R.F., Naylor, A.R., Brindle, N.P.J.: Angiogenesis and the atherosclerotic carotid plaque: An association between symptomatology and plaque morphology. Journal of Vascular Surgery 30, 261–268 (1999)
Feinstein, S.B.: Contrast ultrasound imaging of the carotid artery vasa vasorum and atherosclerotic plaque neovascularization. Journal of the American College of Cardiology 48, 236–243 (2006)
Slomka, P.J., Mandel, J., Downey, D., Fenster, A.: Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries. Ultrasound in Medicine & Biology 27, 945–955 (2001)
Nanayakkara, N.D., Chiu, B., Samani, A., Spence, J.D., Samarabandu, J., Fenster, A.: A ”twisting and bending” model-based nonrigid image registration technique for 3-D ultrasound carotid images. IEEE Transactions on Medical Imaging 27, 1378–1388 (2008)
Nanayakkara, N.D., Chiu, B., Samani, A., Spence, J.D., Samarabandu, J., Parraga, G., Fenster, A.: Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries. Medical Physics 36, 373–385 (2009)
Reinertsen, I., Descoteaux, M., Siddiqi, K., Collins, D.L.: Validation of vessel-based registration for correction of brain shift. Medical Image Analysis 11, 374–388 (2007)
Besl, P.J., McKay, N.D.: A method for registration of 3-d shapes. IEEE Trans. Pattern Anal. Mach. Intell. 14, 239–256 (1992)
Penney, G.P., Blackall, J.M., Hamady, M.S., Sabharwal, T., Adam, A., Hawkes, D.J.: Registration of freehand 3D ultrasound and magnetic resonance liver images. Medical Image Analysis 8, 81–91 (2004)
Carvalho, D.D.B., Klein, S., Akkus, Z., ten Kate, G.L., Schinkel, A.F.L., Bosch, J.G., van der Lugt, A., Niessen, W.J.: Estimating 3d lumen centerlines of carotid arteries in free-hand acquisition ultrasound. International Journal of Computer Assisted Radiology and Surgery 7, 207–215 (2012)
Tang, H., van Walsum, T., van Onkelen, R.S., Klein, S., Hameeteman, K., Schaap, M., van den Bouwhuijsen, Q.J.A., Witteman, J.C.M., van der Lugt, A., van Vliet, L.J., Niessen, W.J.: Multispectral MRI centerline tracking in carotid arteries. In: SPIE: Medical Imaging (2011)
Jian, B., Vemuri, B.C.: Robust Point Set Registration Using Gaussian Mixture Models. IEEE Transactions on Pattern Analysis and Machine Intelligence 33, 1633–1645 (2011)
Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P.W.: elastix: a toolbox for intensity-based medical image registration. IEEE Transactions on Medical Imaging 29, 196–205 (2010)
Sled, J.G., Zijdenbos, A.P., Evans, A.C.: A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Transactions on Medical Imaging 17, 87–97 (1998)
Perona, P., Malik, J.: Scale-space and edge detection using anisotropic diffusion. IEEE Transactions on Pattern Analysis and Machine Intelligence 12, 629–639 (1990)
Wang, D., Klatzky, R.L., Amesur, N., Stetten, G.: Carotid Artery and Jugular Vein Tracking and Differentiation Using Spatiotemporal Analysis. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006, Part I. LNCS, vol. 4190, pp. 654–661. Springer, Heidelberg (2006)
Gee, A., Prager, R., Treece, G., Berman, L.: Engineering a freehand 3D ultrasound system. Pattern Recognition Letters 24, 757–777 (2003)
Chui, H., Rangarajan, A.: A new point matching algorithm for non-rigid registration. Computer Vision and Image Understanding 89, 114–141 (2003)
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., Suetens, P.: Multimodality image registration by maximization of mutual information. IEEE Transactions on Medical Imaging 16, 187–198 (1997)
Viola, P., Wells III, W.M.: Alignment by maximization of mutual information. Int. J. Comput. Vision 24, 137–154 (1997)
Klein, S., Pluim, J.P.W., Staring, M., Viergever, M.A.: Adaptive Stochastic Gradient Descent Optimisation for Image Registration. Int. J. Comput. Vision 81, 227–239 (2009)
Thevenaz, P., Unser, M.: Optimization of mutual information for multiresolution image registration. IEEE Transactions on Image Processing 9, 2083–2099 (2000)
Tang, H., van Onkelen, R.S., van Walsum, T., Hameeteman, R., Schaap, M., Tori, F.L., van den Bouwhuijsen, Q.J.A., Witteman, J.C.M., van der Lugt, A., van Vliet, L.J., Niessen, W.J.: A Semi-automatic Method for Segmentation of the Carotid Bifurcation and Bifurcation Angle Quantification on Black Blood MRA. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010, Part III. LNCS, vol. 6363, pp. 97–104. Springer, Heidelberg (2010)
Dice, L.R.: Measures of the amount of ecologic association between species. Ecology 26, 297–302 (1945)
Underhill, H.R., Kerwin, W.S., Hatsukami, T.S., Yuan, C.: Automated measurement of mean wall thickness in the common carotid artery by MRI: a comparison to intima-media thickness by B-mode ultrasound. Journal of Magnetic Resonance Imaging: JMRI 24, 379–387 (2006)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Carvalho, D.D.B. et al. (2012). Registration of Free-Hand Ultrasound and MRI of Carotid Arteries through Combination of Point-Based and Intensity-Based Algorithms. In: Dawant, B.M., Christensen, G.E., Fitzpatrick, J.M., Rueckert, D. (eds) Biomedical Image Registration. WBIR 2012. Lecture Notes in Computer Science, vol 7359. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31340-0_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-31340-0_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31339-4
Online ISBN: 978-3-642-31340-0
eBook Packages: Computer ScienceComputer Science (R0)