Electrophysiology procedures are in many cases performed under fluoroscopic guidance. As the heart is not visible under fluoroscopy, a preoperatively acquired heart model of the patient may be fused with the live X-ray images to provide the physician with a better orientation. This heart model needs to be registered to the fluoroscopic images. Currently, registration is performed manually, e.g., after contrast injection into the left atrium during atrial fibrillation procedures. We propose a novel visualization of the heart model that shows the same structures as the contrast agent and allows an easy identification of corresponding landmarks and features in both the model and the angiography images.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Calkins H, Brugada J, Packer DL, et al. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. Europace. 2007;9(6):335.
Fuster V, Rydén LE, Cannom DS, et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation. J Am Coll Cardiol. 2006;48(4):854.
Wittkampf FHM, Wever EFD, Derksen R, et al. LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes. Circulation. 1999;99(10):1312–7.
Dilling-Boer D, van der Merwe N, Adams J, et al. Ablation of focally induced atrial fibrillation:. J Cardiovasc Electrophysiol. 2004;15(2):200–5.
De Buck S, Maes F, Ector J, et al. An augmented reality system for patient-specific guidance of cardiac catheter ablation procedures. IEEE Trans Med Imaging. 2005;24(11):1512 –24.
Brost A, Bourier F, Kleinoeder A, et al. AFiT: atrial fibrillation ablation planning tool. Proc VMV. 2011; p. 223–30.
Möller T, Haines E, Hoffman N. Real-time rendering. AK Peters Limited; 2008.
Bourier F, Vukajlovic D, Brost A, et al. Pulmonary vein isolation supported by MRI-derived 3D-augmented biplane fluoroscopy: a feasibility study and a quantitative analysis of the accuracy of the technique. J Cardiovasc Electrophysiol. 2007;115:3057–63.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Hoffmann, M., Bourier, F., Strobel, N., Hornegger, J. (2013). Structure-Enhanced Visualization for Manual Registration in Fluoroscopy. In: Meinzer, HP., Deserno, T., Handels, H., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2013. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-36480-8_43
Download citation
DOI: https://doi.org/10.1007/978-3-642-36480-8_43
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-36479-2
Online ISBN: 978-3-642-36480-8
eBook Packages: Computer Science and Engineering (German Language)