Image Quality Analysis of Limited Angle Tomography Using the Shift-Variant Data Loss Model

  • Conference paper
Bildverarbeitung für die Medizin 2016

Abstract

This paper investigates the application of the shift-variant data loss (SVDL) model in image quality assessment for a state-of-theart reconstruction technique, the weighted total variation (wTV), in limited angle tomography. The SVDL model is used to analyze the acquired frequency information in 2D fan-beam limited angle tomography. The wTV algorithm is applied to reconstruct some specific mathematical phantoms. The experiments show that the reconstructed image quality depends on the relation of the source trajectory and geometric structure of the imaged object, position, shape, size and orientation in particular.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bartolac S, Clackdoyle R, Noo F, et al. A local shift-variant fourier model and experimental validation of circular cone-beam computed tomography artifacts. Med Phys. 2009;36(2):500–12.

    Article  Google Scholar 

  2. Ritschl L, Bergner F, Fleischmann C, et al. Improved total variation-based CT image reconstruction applied to clinical data. Phys Med Biol. 2011;56(6):1545–61.

    Article  Google Scholar 

  3. Sidky EY, Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Med Phys. 2008;53(17):4777–807.

    Article  Google Scholar 

  4. Chen Z, Jin X, Li L, et al. A limited-angle CT reconstruction method based on anisotropic TV minimization. Phys Med Biol. 2013;58(7):2119–41.

    Article  Google Scholar 

  5. Wu H, Maier A, Fahrig R, et al. Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction. Proc SPIE. 2012;8313.

    Google Scholar 

  6. Sidky EY, Kao CM, Pan X., Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. J, Xray Sci Technol. 2006;14:119–39.

    Google Scholar 

  7. Candès EJ, Wakin MB, Boyd SP. Enhangcing sparsity by reweighted l1 minimization. J Fourier Anal Appl. 2008;14:877–905.

    Article  MathSciNet  MATH  Google Scholar 

  8. Maier A, Hofmann H, Berger M, et al. CONRAD: a software framework for conebeam imaging in radiology. Med Phys. 2013;40(11):111914.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Huang, Y. et al. (2016). Image Quality Analysis of Limited Angle Tomography Using the Shift-Variant Data Loss Model. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2016. Informatik aktuell. Springer Vieweg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49465-3_49

Download citation

Publish with us

Policies and ethics