Abstract
Ablation guided by focal impulse and rotor mapping (FIRM) is an alternative treatment for atrial fibrillation in particular for persistent atrial fibrillation. To this end, a basket catheter comprising 64 electrodes is inserted into both the right atrium and left atrium under X-ray guidance to locate electric anomalies. The 3D positions of the electrodes are needed to determine the ablation region. We propose a improved model-based method for 3D reconstruction of this basket catheter based on two X-ray views. In our experiments, we found that the proposed approach outperformed our previous approach. The median error using the proposed method are 1.5mm for phantom data and 2.6mm for clinical data. We also introduced a novel error metric, the overlap rate between ground truth ablation region and reconstructed ablation region. The overall mean overlap rate under optimized viewing angle conditions is 84 ± 14% for phantom data and 72 ± 16% for clinical data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Narayan SM, Krummen DE, Shivkumar K, et al. Treatment of atrial fibrillation by the ablation of localized sources: {CONFIRM} trial. J Am Coll Cardiol. 2012;60(7):628–36.
Eitel C, Hindricks G, Dagres N, et al. EnSite velocity cardiac mapping system: a new platform for 3D mapping of cardiac arrhythmias. Expert Rev Med Devices. 2010;7(2):185–92.
Zhong X, Hoffmann M, Strobel N, et al. Semi-automatic basket catheter reconstruction from two X-ray views. Lect Notes Comput Sci. 2015;9358:379–89.
Hoffmann M, Brost A, Koch M, et al. Electrophysiology catheter detection and reconstruction from two views in fluoroscopic images. IEEE Trans Med Imaging. 2015 ahead of print.
Canero C, Radeva P, Toledo R, et al. 3D curve reconstruction by biplane snakes. Proc Pattern Recognit. 2000;4:563–6.
Haase C, Schaefer D, Doessel O, et al. 3D ablation catheter localisation using individual C-arm X-ray projections. Phys Med Biol. 2014;59(22):6959.
Barbu A, Athitsos V, Georgescu B, et al. Hierarchical learning of curves application to guidewire localization in fluoroscopy. Proc IEEE CVPR. 2007; p. 1–8.
Bourier F, Fahrig R, Wang P, et al. Accuracy assessment of catheter guidance technology in electrophysiology procedures. J Cardiovasc Electrophysiol. 2014;25(1):74–83.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Zhong, X., Hoffmann, M., Strobel, N., Maier, A. (2016). Improved Semi-Automatic Basket Catheter Reconstruction from two X-Ray Views. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2016. Informatik aktuell. Springer Vieweg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49465-3_7
Download citation
DOI: https://doi.org/10.1007/978-3-662-49465-3_7
Publisher Name: Springer Vieweg, Berlin, Heidelberg
Print ISBN: 978-3-662-49464-6
Online ISBN: 978-3-662-49465-3
eBook Packages: Computer Science and Engineering (German Language)