In conventional transmission line protection, a three–zone stepped directional distance scheme is used to provide the primary as well as remote backup protection. The voltage and current phasors are needed by the distance relay for determining the impedance. In this paper, a new frame work is proposed using Data Acquisition Card, which acquires real-time signals of the voltages and currents, processes numerically them in PC and outputs tripping signal to the circuit breaker. Algorithm of quadrilateral distance protection has been implemented using the Simulink/Matlab. To validate the present work, the performance of developed relay is tested by signals generated by Simulink/MATLAB simulator under different conditions. The obtained simulation results are satisfactory.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Power system relaying committee of the IEEE power engineering society: power swing and out-of-step consideration on transmission lines. IEEE PSRC WG D6 (2005)
Bentarzi H, Ouadi A, Chafai M, Zitouni A (2011) Distance protective system performance enhancement using optimized digital filter. In: Proceedings of CSECS ‘11 the 10th WSEAS international conference on circuits, systems, electronics, control and signal processing, Montreux University, Switzerland, 29–31 Dec
Sachdev MS, Baribeau MA (1979) A new algorithm for digital impedance relay. IEEE Trans Power Apparatus Syst 98:2232–2240
Isaksson A (1988) Digital protective relaying through recursive least-squares identification. In: IEE proceedings, Part C: generation, transmission, and distribution, vol 135, pp 441–449
Phadke AG, Hlibka T, Ibrahim M (1976) A digital computer system for EHV substation: analysis and field tests. IEEE Trans Power Apparatus Syst, vol PAS-95, pp 291–301
Internal PNR report (2012)
Ouadi A, Bentarzi H, Maun JC (2011) Phasor measurement unit reliability enhancement using real-time digital filter. Int J Circ, Syst, Sig Process 5(1):1–8
Shrivastava K, Vishwakarma DN (2007) Microcontroller-based numerical quadrilateral relay for the transmission line protection, electric power components and systems, pp 1301–1315
Ziegler G (2006) Numerical distance protection, 2nd edn. Public is Corporate Publishing, Siemens, Erlangen
Ouadi A, Bentarzi H, Maun JC (2009) A new computer based phasor measurement unit framework (published conference proceedings style, IEEE explorer). In: Proceedings 6th international conference SSD’09, Djerba, Tunisia, pp 1–6
Gadgil K (2010) A numerical protection relay solution, texas instruments application report, SLAA466—Sept
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer Science+Business Media Dordrecht
About this paper
Cite this paper
Ouadi, A., Bentarzi, H. (2014). A New Computer Based Quadrilateral Distance Relay Framework for Power Transmission Lines. In: Huang, YM., Chao, HC., Deng, DJ., Park, J. (eds) Advanced Technologies, Embedded and Multimedia for Human-centric Computing. Lecture Notes in Electrical Engineering, vol 260. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-7262-5_55
Download citation
DOI: https://doi.org/10.1007/978-94-007-7262-5_55
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-7261-8
Online ISBN: 978-94-007-7262-5
eBook Packages: EngineeringEngineering (R0)