Digital mammographic systems are being introduced by a number of manufacturers, and will soon be entering the market. Clinical evaluations of equipment from three commercial manufacturers are being performed by our consortium (International Digital Mammography Development Group(IDMDG)). Each manufacturer’s approach to digital mammography has inherent trade-offs which may reduce image quality, or introduce artefacts and/or inconsistencies in the image. As with conventional film-screen mammography, it is imperative that a quality control program be instituted to ensure maximum achievable image quality. The tests which are performed on these units should be both comprehensive and rational; efficient to perform, yet designed to detect problems and changes in the characteristics of a digital mammographic unit, before there is any impact on clinical image quality. Because there are a number of significantly different implementations of digital mammography, the testing regimen must be capable of finding problems related to the physics of image formation (kVp, filtration, DQE), electronic function (dark noise, cross-talk, RC time constants, A/D saturation, non-linearity), as well as software problems (flat fielding, warping algorithms, round-off error).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Mammography Quality Control Manual (rev. 1994) American College of Radiology, Committee on Quality Assurance in Mammography, R.E. Hendrick, Chairman. American Cancer Society. Aug 1994. ISBN 1-55903-136-0
Grabmaier BC. (1994) Luminescent Materials for Medical Applications. Journal of Luminescence 60/61, pp 967–970.
Theuwissen AJP (1996) Solid-State Imaging with Charge-Coupled Devices. Kluwer Academic Publishers, Dordrecht. ISBN 0-7923-3456-6
Barrett HH, Swindell W. (1981) Radiological Imaging Vol. 1 Academic Press, New York.
Critten JP, Emde KA, Mawdsley GE, Yaffe MJ. (1996) Digital Mammography Image Correction and Evaluation. In Gale AG et al (eds.), Digital Mammography ′96, Elsevier, Amsterdam, pp 455–458.
Fujita H, Tsai D, Itoh T, Doi K, Morishita J, Ueda K, and Ohtsuka A. (1992) A Simple Method for Determining the Modulation Transfer Function in Digital Radiography. IEEE Med. Imag 11(1) pp 34–39.
ISO 12233 Title: Photography-Electronic still picture cameras — Resolution measurements (Draft). http://www.pima.net/itl0a.htm#Resolution/itl0a.htm#Resolution Measurement.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
Mawdsley, G.E., Yaffe, M.J., Maidment, A.D.A., Niklason, L., Williams, M., Hemminger, B.M. (1998). Acceptance Testing and Quality Control of Digital Mammography Equipment. In: Karssemeijer, N., Thijssen, M., Hendriks, J., van Erning, L. (eds) Digital Mammography. Computational Imaging and Vision, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-5318-8_72
Download citation
DOI: https://doi.org/10.1007/978-94-011-5318-8_72
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-6234-3
Online ISBN: 978-94-011-5318-8
eBook Packages: Springer Book Archive