Abstract
Based on the bipolar photovoltaic grid-connected inverter control system, a grid unbalanced fault ride-through control strategy is proposed to support the stable operation of the bipolar photovoltaic grid-connected system. Based on analyzing the operating state of the photovoltaic system when unbalanced voltage sags, a voltage fault ride-through control logic of the bipolar photovoltaic system is proposed to solve the problem of grid-connected current quality during fault. The correctness and usage scenarios of the method are verified by Matlab/Simulink simulation. The results show that for different unbalanced voltage sags, the control method can effectively suppress the grid-connected negative sequence current under the condition of low-voltage sag depth, and keep the grid-connected current within a safe current range.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Li, Z., et al.: Adaptive power point tracking control of PV system for primary frequency regulation of AC microgrid with high PV integration. IEEE Trans. Power Syst. 36(4), 3129–3141 (2021)
Camacho, A., Castilla, M., Miret, J., Vasquez, J.C., Alarcon-Gallo, E.: Flexible voltage support control for three-phase distributed generation inverters under grid fault. IEEE Trans. Ind. Electron. 6(4), 1429–1441 (2013)
Camacho, A., et al.: Reactive power control for voltage support during type C voltage-sags. In: IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society, pp. 3462–3467 (2012)
Sochor, P., Tan, N.M.L., Akagi, H.: Low-voltage-ride-through control of a modular multilevel single-delta bridge-cell (SDBC) inverter for utility-scale photovoltaic systems. IEEE Trans. Ind. Appl. 54(5), 4739–4751 (2018)
Camacho, A., Castilla, M., Miret, J., Borrell, A., de Vicuña, L.G.: Active and reactive power strategies with peak current limitation for distributed generation inverters during unbalanced grid faults. IEEE Trans. Ind. Electron. 62(3), 1515–1525 (2015)
Song, H.-S., Nam, K.: Dual current control scheme for PWM converter under unbalanced input voltage conditions. IEEE Trans. Ind. Electron. 46(5), 953–959 (1999)
Xia, Y., Chen, Y., Song, Y., Strunz, K.: Multi-scale modeling and simulation of DFIG-based wind energy conversion system. IEEE Trans. Energy Convers. 35(1), 560–572 (2020)
Talha, M., Raihan, S.R.S., Rahim, N.A., Akhtar, M.N., Butt, O.M., Hussain, M.M.: Multi-functional PV inverter with low voltage ride-through and constant power output. IEEE Access 10, 29567–29588 (2022)
Lin, X., Han, Y., Yang, P., Wang, C., Xiong, J.: Low-voltage ride-through techniques for two-stage photovoltaic system under unbalanced grid voltage sag conditions. In: 2018 IEEE 4th Southern Power Electronics Conference (SPEC), pp. 1–8 (2018)
Chen, H., Cheng, P.: A DC bus voltage balancing technique for the cascaded H-bridge STATCOM with improved reliability under grid faults. IEEE Trans. Ind. Appl. 53(2), 1263–1270 (2017)
Acknowledgements
The authors gratefully acknowledge the support of the National Science Foundation of China (52007194).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Hu, Y., Xia, Y., Liu, X., Zhao, P., Du, S., Su, J. (2022). Performance Investigation of Grid-Connected PV System with Dual Current Control Under Unbalanced Voltage Sags. In: Fan, W., Zhang, L., Li, N., Song, X. (eds) Methods and Applications for Modeling and Simulation of Complex Systems. AsiaSim 2022. Communications in Computer and Information Science, vol 1713. Springer, Singapore. https://doi.org/10.1007/978-981-19-9195-0_32
Download citation
DOI: https://doi.org/10.1007/978-981-19-9195-0_32
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-19-9194-3
Online ISBN: 978-981-19-9195-0
eBook Packages: Computer ScienceComputer Science (R0)