Skip to main content
Log in

Detection of needle puncture to blood vessel using puncture force measurement

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Although blood sampling is frequently performed, a system to take blood samples automatically has not yet been developed. In the paper, as a first step towards automatic blood sampling, an examination of an automatic method for puncturing blood vessels is described. The force waveforms produced by puncturing rabbit ear veins were measured. A characteristic peak, possibly associated with the needle piercing the vessel wall, was observed in each waveform of ten successful cases of 14 trials. An algorithm that allowed the detection of this peak was developed, and parameters of a filter to improve the accuracy of the algorithm were determined. Using this algorithm, automatic needle punctures were performed in a rabbit ear vein and then were simulated using the data derived from manual needle puncture on four other rabbits. The results gave 30 fully successful cases of 33 trials of needle puncture and showed that measurement of the puncture force may be important for automatic needle puncture of blood vessels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Global Industry Analysts, Inc. (2002): ‘Problems associated with use of manikins’, in ‘Training manikins: a global strategic business report’, Global Industry Analysts, Inc., California, Sec. 2.6 in PDF file.

    Google Scholar 

  • Ichiki, R., Komime, H., Saito, H., Tsuchiya, K., andTogawa, T. (1993): ‘Blood-sampling method mimicking mosquito’,Precis. Mach. Incorp. Life Support Technol.,4, pp. 266–268.

    Google Scholar 

  • Lehtinen, R., andOksala, E. (1979): ‘Penetration of disposable needles’,Int. J. Oral. Surg.,8, pp. 145–148.

    Google Scholar 

  • Lehtinen, R. (1983): ‘Penetration of 27-and 30-gauge dental needles’,Int. J. Oral. Surg.,12, pp. 444–445.

    Google Scholar 

  • Okuno, D., Togawa, T., Saito, H., and Tsuchiya, K. (1998): ‘Development of an automatic blood sampling system-Control of the puncturing needle by measuring forces’.Proc. 20th Ann. Int. Conf. IEEE/EMBS, Hong Kong.

  • Saito, H., andTogawa, T. (1999): ‘Detection of puncturing vessel wall for automatic blood sampling’.Proc. First Joint EMBS/EMBS Conf., Atlanta, p. 868.

  • von Fraunhofer, J. A., Storey, R. J., andMasterson, B. J. (1988): ‘Characterization of surgical needles’,Biomaterials,9, pp. 281–284.

    Google Scholar 

  • Zivanovic, A., andDavies, B. L. (2000): ‘A robotic system for blood sampling’,IEEE Trans. Inf. Technol. Biomed.,4, pp. 8–14.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Saito.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Saito, H., Togawa, T. Detection of needle puncture to blood vessel using puncture force measurement. Med. Biol. Eng. Comput. 43, 240–244 (2005). https://doi.org/10.1007/BF02345961

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02345961

Keywords

Navigation