Noise from implantable Cooper cable

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Cooper cable is made for implanted devices, usually for connection to stimulating electrodes. An experiment has been performed to see whether these cables would be satisfactory for recording electroneurogram (ENG) signals from cuffs. Four cables were subjected to continuous flexion at 2 Hz while submerged in saline. The cables were connected to a low-noise amplifier, and the noise was measured using a spectrum analyser. These cables had not fractured after 184 million flexions, and the noise in the neural band (500–5000 Hz) had not increased owing to age. Noise in the ENG band increased by less than 3 dB owing to the motion. A fifth, worn cable did fail during the experiment, the conductors becoming exposed to the saline, but this was only apparent by extra noise when the cable was in motion. After 184 million flexions, the four cables were given a more severe test: instead of being connected to the amplifier reference node, two of the four cores of each cable were connected to 18V batteries. Two of the cables were then noisier, but only when in motion, presumably because of leakage between cores. Cooper cables are excellent for transmitting neural signals alone; transmission in one cable of neural signals and power supplies should be avoided if possible.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Brindley, G. S. (1995): ‘The first 500 sacral anterior root stimulators: implant failures and their repair’,Paraplegia,33, pp. 5–9

    Google Scholar 

  • Donaldson, N. de N., Zhou, L., Perkins, T. A., Munih, M., Haugland, M., andSinkjaer, T. (2003): ‘Implantable telemeter for long term electroneurographic recordings in animals and man’,Med. Biol. Eng. Comput.,41, pp. 654–664

    Google Scholar 

  • Donaldson, P. E. K. (1983): ‘The Cooper cable: an implantable multiconductor cable for neurological prostheses’,Med. Biol. Eng. Comput.,21, pp. 371–374

    Google Scholar 

  • Donaldson, P. E. K. (1983): ‘The Craggs connector: a termination for Cooper cable’,Med. Biol. Eng. Comput.,23, pp. 195–196

    Google Scholar 

  • Rushton, D. N., Tromans, A. M., andDonaldson, N. de N. (2002): ‘A reconnectable multiway implantable connector’,Med. Eng. Phys.,24, pp. 691–694

    Article  Google Scholar 

  • Struijk, J. J., Thomsen, M., Larsen, J. O., andSinkjaer, T. (1999): ‘Cuff electrodes for long-term recording of natural sensory, information’,IEEE EMBS Mag.,18, pp. 91–98

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. Donaldson.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Carrington, V., Zhou, L. & Donaldson, N. Noise from implantable Cooper cable. Med. Biol. Eng. Comput. 43, 618–621 (2005). https://doi.org/10.1007/BF02351035

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02351035

Keywords

Navigation