Abstract
This study examines the utility of neural networks for detecting coronary artery disease noninvasively by using the clinical examination variables and extracting useful information from the diastolic heart sounds associated with coronary occlusions. It has been widely reported that coronary stenoses produce sounds due to the turbulent blood flow in these vessels. These complex and highly attenuated signals taken from recordings made in both soundproof and noisy rooms were detected and analyzed to provide feature set based on the poles and power spectral density function (PSD) of the Autoregressive (AR) method after Adaptive Line Enhancement (ALE) method. In addition, some physical examination variables such as sex, age, body weight, smoking condition, diastolic pressure, systolic pressure and derivation from them were included in the feature vector. This feature vector was used as the input pattern to the neural network. The analysis was studied on one hundred recordings (63 abnormal, 37 normals). The network correctly identified 84% of the subjects with coronary artery disease and 89% of the normal subjects.
Similar content being viewed by others
References
Akay M, Semmlow JL, Welkowitz W, Bauer M, Kostis J (1990a) Detection of coronary occlusions using AR modelling of diastolic heart sounds. IEEE Trans Biomed Eng BME-37:366–373
Akay M, Semmlow JL, Welkowitz W, Bauer M, Kostis J (1990b) Noninvasive detection of coronary occlusions using eigenvector methods before and after angioplasty. IEEE Trans Biomed Eng BME-37:1095–1105
Akay M (1990) Noninvasive detection of coronary artery disease using advanced signal processing methods. Ph.D. Dissertation, Rutgers University, Piscataway, NJ
Akay M, Welkowitz W, Semmlow JL, Kostis J (1991) Application of the ARMA method to acoustic detection of coronary artery disease. Med Biol Eng Comput 29:365–362
Akay M, Welkowitz W, Semmlow JL, Kostis J (1992) Noninvasive acoustical detection of coronary artery disease using adaptive line enhancer method. Med Biol Eng Comput, in press
Al-Nashash HAM, Kelly SW (1987) Beat-to-beat detection of hispurkinje system signals using adaptive filters. Med. Biol Eng Comput 26:117–125
Berne RM, Levy MN (1986) Cardiovascular physiology. Mosby, St. Louis
Blinowska A, Chatellier G, Bernier J, Larvil M (1991) Bayesian statistics as applied to hypertension diagnosis. IEEE Trans BME-38:699–706
Chen J, Vandewalle J, Sansen W, Vantrappen G, Janssens J (1989) Adaptive method for cancellation of respiratory artifact in electrogastric measurements. Med Biol Eng Comp 27:57–63
Cheng TO (1970) Diagnostic murmer caused by coronary artery stenosis. Ann Int Med 72:543–546
Connor WE, Bristow JD (1985) Coronary heart disease. Lippincott, Philadelphia
Costantini C, Sampaolesi A, Serra CM, Pacheco G, Neuburger J, Conci E, Haendchen R (1991) Coronary venous retroperfusion support high risk angioplasty in patients with unstable angina: preliminary experience. American College of Cardiology 18:283–292
David J-Y, Jones SA, Giddens DP (1991) Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed doppler ultrasound. IEEE Trans BME-38:589–596
Dock W, Zoneraich S (1967) A diastolic murmer arising in a stenosed coronary artery. Am J Med 42:617
Duncan GW, Gruber TO, Dewey CF, Myers GS, Lees RS (1975) Evaluation of carotid stenosis by phonoangiography. N Eng J Med 27:1124–1128
Eaker ED, Packard B, Thom TJ (1989) Epidemiology and risk factors for coronary artery disease in women. Cardiovas Clin 19:129–145
Ferrara ER, Widrow B (1981) Adaptive filtering for signal enhancement. IEEE Trans ASSP 29:458–460
Feyter PJ, Serruys PW, Davies MJ, Richardson P, Lubsen J, Oliver MF (1991) Quantitative coronary angiography to measure progression and regression of coronary atherosclerosis. Circulation 84:412–423
Ganong WF (1981) Review of medical physiology. Lange, Los Altos, pp 485–488
Gillum RF (1987) Coronary artery bypass surgery and coronary angiography in the United States. Am Heart J 113:1255–1260
Goldberg S (1988) Coronary angioplasty. Davis, Philadelphia
Gruntzig AR, King SB, Schlumpf M (1987) Long term follow-up after percutaneous transluminal coronary angioplasty. N Eng J Med 316:1127
Guyton AC (1987) Textbook of medical physiology. Saunders, Philadelphia
Haykin S (1986) Adaptive filter theory. Prentice Hall, Englewood Cliffs
Huang W, Lippmann R (1987) Comparison between neural network and conventional classifiers. Proc IEEE International Conference on Neural networks, pp 485–494
Iwata A, Nagasaka Y, Suzumura N (1990) Data compression of the ECG using neural network for digital holter monitor. IEEE EMBS Magazine, pp 53
Iyer VK, Ramamoorthy PA, Ploysongsang Y (1989) Autoregressive modeling of lung sounds: characterization of source and transmission. IEEE Trans BME-36:1133–1136
Johnson MR (1985) Special diagnostic tests and procedures. Phys Ther 65:1856–1865
Lees RS, Myers GS (1982) Noninvasive diagnosis of arterial disease. Adv Int 23:475–509
Lippmann R (1987) An introduction to computing with neural networks. IEEE ASSP Magazine 4–22
Kartchner MM, McRae LP, Morrison FD (1973) Noninvasive detection and evaluation of carotid occlusive disease. Arch Surg 106:528–535
Kaul S, Newell JB, Chesler DA, Pohost GM, Okada RD, Guiney TE, Boucher CA (1986) Value of computer analysis of exercise thallium images in the noninvasive detection of coronary artery disease. JAMA 255:508–511
Kay SM, Marple SL (1981) Spectral analysis: a modern perspective. Proc IEEE 69:1380–1419
Kelly MF, Parker PA, Scott RN (1990) The application of neural networks to myoelectric analysis: a preliminary study. IEEE Trans Biomed Eng 37:221–230
Kentie MA, Van Der Schee ET, Grashius JL, Smout AJPM (1981) Adaptive filtering of canine electrogastrographic signals — Part I; System design. Med Biol Eng Comput 19:759–764
Khalifa AMA, Giddens DP (1981) Characterization of post-stenotic flow disturbances. J Biomech 14:275–296
Khan SS, Nessim S, Gray R, Czer LS, Chaux A, Matloff J (1990) Increased mortality of women in coronary artery bypass surgery: evidence for referral bias. Ann Int Med. 107:19–25
Krupp MA (1982) Current medical diagnosis and treatment. Lange, Los Altos, pp 193–210
Kurogi S (1991) Speech recognition by an artificial neural network using findings on the afferent auditory system. Biol Cybern 64:243–250
Kurtz KJ (1984) Dynamic vascular ausculation. Am J Med 76:1066–1074
Larvil M, Chateller G, Degoulet P, Sauquet D, Jeunemaitre X, Menard J, Rovani C (1988) ARTEL: an expert system in hypertension for the general practitioner. In: Lecture Notes in Medical Informatics. Springer, Berlin Heidelberg New York pp 314–321
Makhoul J (1981) Spectral linear properties and applications. Trans ASSP 29:282–296
Marmarou RM, White MW, Marmarou A (1990) Classification of somatosensory of evoked potentials recorded from patients with severe head injuries. IEEE BME Mag 43–49
Marple SL (1976) Conventional fourier, autoregressive, and special ARMA methods of spectrum analysis. Engineer's Dissertation, Stanford University
Orfanidis SJ (1988) Optimum signal processing. Macmillan, New York
Padmanabhan V, Fisher R, Semmlow JL, Welkowitz W, Kostis J (1989) High sensitivity PCG transducer for extended frequency applications. Proc IEEE Front Med 57–59
Rumelhart D, Hunton GE, Williams RJ (1986) Learning internal representations by error propagation. Chap 8, Vol I: Parallel Distributed Processing: Explorations in the microstructure of cognition. MIT Press, Cambridge pp 318–362
Sejnowski T, Rosenberg CR (1986) NET talk: a parallel network that learns to read aloud. Johns Hopkins University Technical Reports, JHU/EECS-86/01
Semmlow JL, Welkowitz W, Kostis J, Mackenzie JW (1983) Coronary artery disease-correlates between diastolic auditory characteristic and coronary artery stenoses. IEEE Trans Biomed Eng 30:136–139
Semmlow JL, Akay M, Welkowitz W (1990) Noninvasive detection of CAD using parametric analysis methods. IEEE, EMBS Mag 9:33–37
Shen D, Semmlow J, Welkowitz W (1990) Automated identification of artifact-free diastolic heart sounds. Proc IEEE Front Med 569–570
Sox HC, Blatt MA, Higgins MC, Marton KI (1988) Medical decision making. Butterworth, London
Stolzenberg J (1980) Stress-thalium-201 scanning in CAD. Med Clin North Am 64:149–162
Teichholtz LE (1984) Cardiointegram detection CAD using in normal resting electrocardiograms. J Am Coll Cardiol 3:598
Topol EJ (1989) Emergency strategies for failed percutaneous transluminal coronary angioplasty. Am J Cardiol 63:249–250
Vogl TP, Mangis JK, Rigler JK, Zink WT, Alken TL (1988) Accelerating the convergence of the back propagation method. Biol Cybern 59:257–263
Wegner NK (1990) Gender, coronary artery disease, and coronary by-pass surgery. Ann Int Med 112:557–558
Welkowitz W, Akay M, Wang JZ, Semmlow J, Kostis J (1990) A model for disturbed coronary artery flow with phonocardiographic verification. In: Sideman S, Beyer R (eds) Activation, circulation and transport in the cardiac muscle. Kluwer, New York
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Akay, M. Noninvasive diagnosis of coronary artery disease using a neural network algorithm. Biol. Cybern. 67, 361–367 (1992). https://doi.org/10.1007/BF02414891
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02414891