Skip to main content

Automatic determination of the newborn's femoral head from three-dimensional ultrasound image data

  • Basic Tools and Applications in Hip and Pelvis Surgery
  • Conference paper
  • First Online:
CVRMed-MRCAS'97 (CVRMed 1997, MRCAS 1997)

Abstract

The infant's femoral head form and position relative to the acetabulum are the major parameters for the diagnosis of a hip joint dysplasia. The analysis can be performed using conventional ultrasound 2D-images, which virtually cut the hip joint in a specific plane. The joint's shape is scored by geometric measures taken from the image. The imaging in a defined plane is tedious and demands some experience. Furthermore the reporting of a spatial geometry through 2D-images tends to be subjective and incomplete. To consider the entire joint geometry, a 3D-data set of conventional ultrasound images is recorded along with the transducer movement. The femoral head is measured automatically in the spatially arranged images by fitting a virtual sphere, which approximates the femoral head's contours. A pilot study based on 20 3D-ultrasound data sets of hip joints of infants aging 2 days–12 weeks shows highly accurate coincidence of the automatically calculated diameter and centre parameters with those of control measurements, i.e. virtual spheres interactively placed and parametrized.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. R. Graf. The Diagnosis of congenital hip joint dislocation by the ultrasonic compound treatment. Arch Orthop Trauma Surg 1980 (97): 117–133

    Article  PubMed  Google Scholar 

  2. E.O. Gerscovich, A. Greenspan, M. Cronan, L. Karol, J.P. McGahan. Three-dimensional Sonographic Evaluation of Developmental Dysplasia of the Hip: Preliminary Findings. Radiology 1994 (190): 407–410

    PubMed  Google Scholar 

  3. P.R. Krishnaiah, L.N. Kanal, editors. Handbook of Statistics, Vol. 2. North-Holland, Amsterdam, 1982

    Google Scholar 

  4. H.M. Overhoff, O. Grolle, P.C. Müller. Computer-based Planning and Documentation of a Femoral Osteosynthesis, in H.U. Lembke et al., editors. Proceedings of the International Symposium Computer Assisted Radiology CAR'95, Springer-Verlag, 1995: 1241–1244

    Google Scholar 

  5. R. Wespe, A. Wallin, K. Klaue, K. Schneider, R. Ganz. Three-Dimensional Quantification of Established Femoral, in H.U. Lembke et al., editors Proceedings of the International Symposium Computer Assisted Radiology CAR'89, Springer-Verlag, 1989, 362–368

    Google Scholar 

  6. J. Wittenburg. Dynamics of Systems of Rigid Bodies, Verlag B.G. Teubner, 1977

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Jocelyne Troccaz Eric Grimson Ralph Mösges

Rights and permissions

Reprints and permissions

Copyright information

© 1997 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Overhoff, H.M., Lazovic, D., Franke, J., von Jan, U. (1997). Automatic determination of the newborn's femoral head from three-dimensional ultrasound image data. In: Troccaz, J., Grimson, E., Mösges, R. (eds) CVRMed-MRCAS'97. CVRMed MRCAS 1997 1997. Lecture Notes in Computer Science, vol 1205. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0029278

Download citation

  • DOI: https://doi.org/10.1007/BFb0029278

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-62734-0

  • Online ISBN: 978-3-540-68499-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics