Skip to main content

Surgical probe design for a coincidence imaging system without a collimator

  • 1. Image Formation And Reconstruction
  • Conference paper
  • First Online:
Information Processing in Medical Imaging (IPMI 1991)

Part of the book series: Lecture Notes in Computer Science ((LNCS,volume 511))

Abstract

Surgical probes used in nuclear medicine can be maneuvered close to a suspected tumor site, thereby achieving higher resolution and sensitivity than external gamma cameras. Tomography with handheld probes is not possible, however, so it is difficult to determine whether an increase in the photon count rate is caused by features near the probe or by variations in the distant background radiation. Our group has experimented with several probe designs that address this problem. This paper describes a probe that images nearby objects without a collimator and is insensitive to inhomogeneities in the distant background level. The probe, which is used with a radionuclide that emits multiple photons per decay, such as 111In, consists of a collimatorless array of gamma-ray detectors connected by coincidence circuitry. We used a Monte Carlo routine to simulate data collection from such a system and reconstructed the images using the pseudoinverse obtained by singular value decomposition (SVD). The images show a significant suppression of distant sources when compared to a probe equipped with a conventional parallel-hole collimator.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Barrett HH, Aarsvold JN and Roney TJ (1991). Null functions and eigenfunctions: tools for the analysis of imaging systems. In: Information Processing in Medical Imaging. Ortendahl DA and Llacer J (eds), Wiley-Liss, New York, pp. 211–226.

    Google Scholar 

  • Boetticher H, Helmers H, Schreiber P, Schmitz-Feuerhake I (1982). Advances in γ-γ-coincidence scintigraphy with the scintillation camera. Phys. Med. Biol. 27:1495–1506.

    Google Scholar 

  • Chung V, Chak KC, Zacuto P and Hart HE (1980). Multiple photon coincidence tomography. Semin. Nucl. Med. 10:345–354.

    Google Scholar 

  • Hartsough NE, Barber HB, Woolfenden JM, Barrett HH, Hickernell HS and Kwo DP (1989). Probes containing gamma radiation detectors for in vivo tumor detection and imaging. Proc. SPIE 1068:92–99.

    Google Scholar 

  • Hickernell TS (1988). Statistical decision making with a dual-detector probe. Ph.D. Dissertation, University of Arizona.

    Google Scholar 

  • Hickernell TS, Barber HB, Barrett HH and Woolfenden JM (1988). A dual-detector probe for surgical tumor staging. J. Nucl. Med. 29:1101–1106.

    Google Scholar 

  • Liang Z and Jaszczak R (1990). Comparisons of multiple photon coincidence imaging techniques. IEEE Trans. Nucl. Sci. 37:1282–1292.

    Google Scholar 

  • Monahan WG and Powell MD (1973). Three-dimensional imaging of radionuclide distribution by gamma-gamma coincidence detection. In: Tomographic Imaging in Nuclear Medicine. Freedman GS (ed), Society of Nuclear Medicine, New York, pp. 165–175.

    Google Scholar 

  • Powell MD (1989). Multiphoton, time-of-flight three-dimensional radionuclide imaging. Med. Phys. 16:809–812.

    Google Scholar 

  • Schmitz-Feuerhake I (1970). Studies on three-dimensional scintigraphy with γ-γ-coincidences. Phys. Med. Biol. 15:649–656.

    Google Scholar 

  • Woolfenden JM and Barber HB (1989). Radiation detector probes for tumor localization using tumorseeking radioactive tracers. Am. J. Roentgenol. 153:35–39 (invited paper).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Alan C. F. Colchester David J. Hawkes

Rights and permissions

Reprints and permissions

Copyright information

© 1991 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Saffer, J.R., Barrett, H.H., Barber, H.B., Woolfenden, J.M. (1991). Surgical probe design for a coincidence imaging system without a collimator. In: Colchester, A.C.F., Hawkes, D.J. (eds) Information Processing in Medical Imaging. IPMI 1991. Lecture Notes in Computer Science, vol 511. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0033738

Download citation

  • DOI: https://doi.org/10.1007/BFb0033738

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-54246-9

  • Online ISBN: 978-3-540-47521-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics