Abstract
Due to the separation of the two sides of the coupling network, the acquisition of data on the operating state variables of a transcutaneous energy transmission system (TETS) inside the human body is difficult. A non-measurable state estimation approach is used in this work to facilitate the estimation of non-measurable variables on the secondary side of the TETS, including the current of the secondary coil and the output voltage of the secondary side. The estimation algorithm is based on a discrete dynamic mathematical model of the TETS. Following this model, using the extended Kalman filter (EKF) algorithm, the complexity of the TETS for artificial human implants can be reduced, while the reliability is simultaneously enhanced. Additionally, as an adaptive filter, the EKF can also successfully filter out processing noise during energy transmission. All of the results are verified by simulation using MATLAB.
Similar content being viewed by others
References
S. Arai, H. Miura, F. Sato, H. Matsuki, T. Sato, Examination of circuit parameters for stable high efficiency TETS for artificial hearts. IEEE Trans. Magn. 41, 4170–4172 (2005)
S. Atluri, M. Ghovanloo, A wideband, power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers. IEEE Trans. Circuits Syst. I: Fundam. Theory Appl. 54, 1131–1134 (2007)
B. Anderson, J. Moore, Optimal Filtering (Prentice-Hall, Englewood Cliffs, 1979)
W. Fang, H. Tang, W. Liu, Modeling and analyzing an inductive contactless power transfer system for artificial hearts using the generalized state space averaging method. J. Comput. Theor. Nanosci. 4, 1412–1416 (2007)
G.F. Franklin, J.D. Powell, M. Workman, Digital Control of Dynamic Systems, 3rd edn. (Addison-Wesley, Reading, 1998), p. 388
W. Liu, H. Tang, Analysis of voltage source inductive coupled power transfer systems based on zero phase angle resonant control method, in IEEE Conference ICIEA, Harbin, P.R. China, May 23–25, pp. 1873–1877 (2007)
H. Miura, S. Arai, Y. Kakubari, F. Sato, H. Matsuki, T. Sato, Improvement of the transcutaneous energy transmission system utilizing ferrite cored coils for artificial hearts. IEEE Trans. Magn. 42, 3578–3580 (2006)
S.R. Sanders, J.M. Noworolski, X.Z. Liu, G.C. Verghese, Generalized averaging method for power conversion circuits. IEEE Trans. Power Electron. 6, 251–259 (1991)
F. Sato, T. Nomoto, G. Kano, H. Matsuki, T. Sato, A new contactless power-signal transmission device for implanted functional electrical stimulation (FES). IEEE Trans. Magn. 40, 2964–2966 (2004)
J.C. Schuder, Powering an artificial heart: Birth of the inductively coupled radio frequency system in 1960. Artif. Organs 26, 909–915 (2002)
P. Si, A.P. Hu, J.W. Hsu, M. Chiang, Y. Wang, S. Malpas, D. Budgett, Wireless power supply for implantable biomedical device based on primary input voltage regulation, in IEEE Conference ICIEA, Harbin, P.R. China, May 23–25, pp. 235–239 (2007)
M.P. Theodoridis, S.V. Mollov, Distant energy transfer for artificial human implants. IEEE Trans. Biomed. Eng. 52, 1931–1938 (2005)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Liu, W., Tang, H., Fang, W. et al. Estimation of the Non-Measurable State Variables of a Transcutaneous Energy Transmission System for Artificial Human Implants Using Extended Kalman Filters. Circuits Syst Signal Process 28, 581–593 (2009). https://doi.org/10.1007/s00034-009-9099-2
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00034-009-9099-2