A new concept for test equipment for testing large HV and UHV cables on-site

  • cigre 2010
  • Published:
e & i Elektrotechnik und Informationstechnik Aims and scope Submit manuscript

Summary

The number of projects involving long and extra long HV and UHV AC cables as well as HVDC cable connections can be observed to increase (Cao et al., 2008; Kabouris et al., 2006). At the same time, operating voltage levels are increasing, accentuating the need for more powerful on-site test systems needed to prove the integrity of the insulation before energization. Low cost and ease of operation are other important features of such systems. As a matter of fact, traditional methods and test systems for routine and on-site testing of these cables come to their limit – technically and economically – as the lengths and voltage levels increase (Marelli, 2008). The logistics for the arrangement of tests as well as the testing itself are challenging (Schröder et al., 2006). Development of power electronics has now made it possible to realize high voltage DC interconnections that do not exhibit polarity reversal at reversal of power flow. As a result of this, extruded XLPE cables are now coming to the fore in high voltage DC application, although methods and test equipment for routine and on-site testing show some open issues so far. Space charges in the insulation, initiated by the test voltage during testing, are unacceptable, and this leads to the requirement that testing must be made at an alternating voltage, which can be very low frequency without creating space charge. Available test equipment for power frequency testing is not feasible for testing extruded DC cables, among other reasons, due to the lengths usually associated with DC cables. These open issues can be solved with a newly developed on-site test system that provides the reliability of established test methods and test equipment, but exhibiting lower weight, dimensions and power consumption compared to existing systems. At the same time, the on-site test system as well as the prearrangement of the tests and the testing itself are less cost intensive. Extra long cables (i.e. high capacitance) could be tested with the equipment, which by virtue of its smaller dimension is easier to handle and thus reducing the testing logistics dramatically. For example where one of the systems on the market would require two trailers of equipment for a test on a high voltage cable, only a single trailer would be needed with the new system, or a roll on/roll off test can be carried out without the use of any crane on-site. A reduction in weight by a factor of 3 is expected compared to today’s on-site test equipment, a gain which also is reflected in reduced volume.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Austrian Patent 506.815 (resp. PCT WO 2009/143543)

  • Austrian Patent 506.816 (resp. PCT WO 2009/143544)

  • Cao, X., Liu, Y., Fang, H., Gong, Z. (2008): 500 kV power supply cable project for city central zone of Shanghai. Paper B1-106 Cigre Session 2008

  • Gockenbach, E. (2002): Grundsätzliche Untersuchungen zum Durchschlagverhalten kunststoffisolierter Kabel bei Spannungen unterschiedlicher Frequenz. BEWAG-Symposium, Berlin 2002

  • IEC 60060-1 (1989): High-voltage test techniques, Part 1: General definitions and test requirements

  • IEC 60060-2 (2010): High-voltage test techniques, Part 2: Measuring systems

  • IEC 60060-3 (2006): High-voltage test techniques, Part 3: Definitions and requirements for on-site testing

  • IEC 60270 (2000): High-voltage test techniques – partial discharge measurements

  • IEC 60840 (2004): Power cables with extruded insulation and their accessories for rated voltages above 30 kV (U m = 36 kV) up to 150 kV (U m = 170 kV) – Test methods and requirements

  • IEC 62067 (2006): Power cables with extruded insulation and their accessories for rated voltages above 150 kV (U m = 170 kV) up to 500 kV (U m = 550 kV) – Test methods and requirements

  • Kabouris, J., Efstathiou, S., Maissis, A., Antonopoulos, G., Georgantzis, G., Papadopoulos, M., Boulaxis, N. (Greece) (2006): Supply of Islands through long distance submarine cables: problems and prospects (case study: Cycladic Interconnection). Paper B1-103 Cigre Session 2006

  • Marelli, M. (2008): Cigre 2008 Proc. B1 PS1 Q1_04, Cigre Session 2008

  • Moh, S. C. (2003): Very low frequency testing – its effectiveness in detecting hidden defects in cables. CIRED 03, Barcelona, Session 1, Paper 84

  • Muhr, M., Sumereder, C., Woschitz, R. (2001): The use of the 0.1 Hz cable testing method as substitution to 50 Hz measurement and the application for PD measuring and cable fault location. 12th Int. Symp. on High Voltage Engineering (ISH), 2001, Bangalore

  • Plath, R., Kalkner, W., Krage, I. (1997): Vergleich von Diagnosesystemen zur Beurteilung des Alterungszustandes PE/VPE-isolierter Mittelspannungskabel. Elektrizitätswirtschaft, Jg. 96, 20: 1130

  • Schröder, G., Weinlein, A., Herrmann, U., Kluge, A., Vaterrodt, K., Plath, R. (2006): Das St. John’s Wood – Elstree-Projekt: Inbetriebnahme eines 400-kV-VPE-Kabelsystems großer Länge. ETG Fachtagung 2006, Kassel, Germany

  • Voigt, G., Mohaupt, P. (2003): Partial discharge measurements on service aged medium voltage cables at different frequencies. Jicable 2003, Versailles

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mohaupt, P., Bergman, A. A new concept for test equipment for testing large HV and UHV cables on-site. Elektrotech. Inftech. 127, 350–353 (2010). https://doi.org/10.1007/s00502-010-0790-6

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00502-010-0790-6

Keywords

Navigation