Literatur
Akbari A., Werle P., Borsi H., Gockenbach E. (2002): Transfer function-based partial discharge localization in power transformers: a feasibility study. IEEE Insul. Mag., 18(5), 22–32.
CIGRE Working Group A2/26 (2008): Mechanical condition assessment of transformer windings using frequency response analysis (FRA). Technical Brochure.
Druckschrift Emil Haefely AG, Basel (1987): Stoßoszilloskop Typ 721. 5 Aufl.
Druckschrift Emil Haefely AG, Basel (2011): High resolution impulse analyzing system Hias 743.
Druckschrift HighVolt (2011): Digital Impulse Analyzers Type MIAS.
Garnacho F., Simon P., Gockenbach E., Hackemack K., Berlijn S., Werle P. (2002): Evaluation of lightning impulse voltage based on experimental results. ELECTRA, 20, 31–39.
Gockenbach E. (1991): A simple and robust evaluation procedure for high voltage impulses. In: IEEE intern. symposium on digital techniques in high voltage measurement, Toronto. Session 3.
IEC 60060-1 (1989): High-voltage test techniques—Part 1: General definitions and test requirements, Ed. 2.0, 1989-11.
IEC 61083-1 (1991): Instruments and software used for measurement in high-voltage impulse tests—Part 1: Requirements for instruments, Ed. 1.0, 1991-08.
IEC 61083-2 (1996): Digital recorders for measurements in high-voltage impulse tests—Part 2: Evaluation of software used for the determination of the parameters of impulse waveforms, Ed. 1.0, 1996-07.
IEC 60270 (2000): High-voltage test techniques—Partial discharge measurements, Ed. 3.0, 2000-12.
IEC 60060-3 (2006): High-voltage test techniques—Part 3: Definitions and requirements for on-site testing, Ed. 1.0, 2006-02.
IEC 60060-1 (2010): High-voltage test techniques—Part 1: General definitions and test requirements, Ed. 3.0, 2010-09.
Leibfried T. (1996): Die Analyse der Übertragungsfunktion als Methode zur Überwachung des Isolationszustandes von Großtransformatoren. Dissertation, Universität Stuttgart.
Obralic A., Kalkner W., Kaufhold M., Plath R. (2006): Verbesserte Zustandsbewertung durch neue Auswerteverfahren bei der Synchronen Mehrstellen-TE-Messung an Hochspannungsmaschinen. ETG Fachtagung Diagnostik, S. 107–112.
Poulin B., Malewski R. (1988): Impulse testing of power transformers using the transfer function method. IEEE Trans. Power Deliv., 3, 476–489.
Project IEC 61083-3 (2012): Ed. 1.0, Instruments and software used for measurement in high-voltage and high-current tests—Part 3: Requirements for digital instruments for tests with alternating and direct voltages and currents. IEC Website.
Project IEC 61083-4 (2012): Ed. 1.0, Instruments and software used for measurements in high-voltage and high-current tests—Part 4: Requirements for software for tests with alternating and direct currents and voltages. IEC Website.
Project IEC 60270 (2012): am1 Ed. 3.0 Amendment 1: High-voltage test techniques—Partial discharge measurements. IEC Website.
Project IEC 62478 (2012): Ed. 1.0 High voltage test techniques—Measurement of partial discharges by electromagnetic and acoustic methods. IEC Website.
Schon K. (2010): Stoßspanungs- und Stoßstrommesstechnik. Springer, Berlin. ISBN 978-3-642-13117-2.
Schwab A. J. (2011): Hochspannungsmesstechnik. Springer, Berlin. ISBN 978-3-642-19881-6.
Schwab A. J., Kürner W. (2007): Elektromagnetische Verträglichkeit. Springer, Berlin. ISBN 978-3-540-42004-0.
The Electric Power Industry Standard of People’s Republic of China (2005): Frequency response analysis on winding deformation of power transformers. DL Standard, DL/T911-2004, ICS 27.100, F24, Document no. 15182-2005, June 2005.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gockenbach, E. Einzug der digitalen Messwerterfassung in die Hochspannungsprüftechnik. Elektrotech. Inftech. 129, 342–348 (2012). https://doi.org/10.1007/s00502-012-0033-0
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00502-012-0033-0