Skip to main content
Log in

Respirometer by a piezo device and its application to triage

  • Original Article
  • Published:
Artificial Life and Robotics Aims and scope Submit manuscript

Abstract

In this paper, we present a novel respirometer using the effect of piezo devices and show its application to triage. We found that blowing on the piezo device generated several 100 mV voltage and also synchronizes with the respiration. Our detailed investigations of the phenomena showed that it was caused by the pyroelectric effect. In general, the piezo device when used as a sensing device generates output voltage in a batteryless manner and also functions as a buzzer, which can lead to a compact, simple and low-power respirometer. Here, the piezo device was used as a base of respirometer and not only as a respirometer, but also as an alarm sound generator. Thus, the proposed respirometer was realized only by one piezo device and a low-powered microprocessor driven by a small battery. We applied the respirometer to triage and realized a triage sensing system. In the system, we employed the triage priority determination procedure defined as an international standard. The triage sensing system set in a mask detects respiration and displays its condition by turning an LED on and off, synchronizing the respiration and also generating the alarm sound when the respiration falls into the pre-specified ill conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Fleming AJ, Moheimani SOR, Behrens S (2005) Synthesis and implementation of sensor-less active shunt controllers for electromagnetically actuated systems. IEEE Trans Control Syst Technol 13(2):246–261

    Article  Google Scholar 

  2. Chagjiang W, Guojun T, Nanyan W (1993) High performance speed-sensor-less AC drive system for induction motor. IEEE TENCON’93 5:602–606

    Google Scholar 

  3. Norhisam M, Ezril H, Senan M, Mariun N, Wakiwaka H, Nirei M (2006) Positioning system for sensor less linear DC motor. In: IEEE international power and energy conference PECON 2006, Putrajaya, Malaysia, pp 476–481

  4. Sayouti Y, Abbou A, Akherraz M, Mshoudi H (2011) Sensorless low speed control with ANN MRAS for direct torque controlled induction motor drive. In: Proceedings of the 2011 international conference on power engineering, energy and electrical drives, Torremolinos (Malaga), Spain

  5. Pang CK, Guo G, Chen BM, Lee TH (2006) Self-sensing actuation for nanopositioning and active-mode damping in dual-stage HDDs. IEEE/ASME Trans Mechatron 11(3):328–338

    Article  Google Scholar 

  6. Putra AS, Huang S, Tan KK, Panda SK, Lee TH (2008) Self sensing actuation with adaptive control in applications with switching trajectory. IEEE/ASME Trans Mechatron 13(1):104–111

    Article  Google Scholar 

  7. Das T, Mukherjee R (2009) Shared-sensing and control using reversible transducers. IEEE Trans Control Syst Technol 17(1):242–248

    Article  Google Scholar 

  8. Badel A, Qiu J, Nakano T (2008) Self-sensing force control of a piezoelectric actuator. IEEE Trans Ultrason Ferroelectr Freq Control 55(12):2571–2581

    Article  Google Scholar 

  9. Rakotondrabe M, Ivan IA, Khadraoui S, Lutz P, Chaillet N (2015) Simultaneous displacement/force self-sensing in piezoelectric actuators and applications to robust control. IEEE/ASME Trans Mechatron 20(2):519–531

    Article  Google Scholar 

  10. Yoshida T, Kobayashi K, Kurihara Y, Shiroi N, Watanabe K (2017) Multiple-input/multiple-output characteristics of piezo devices and an application for triage. IEEE Sens J 17(5):1434–1442

    Article  Google Scholar 

  11. Jeffe B, Cook WR, Jeffe H (1971) Piezo ceramics. Academic, New York

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kazuyuki Kobayashi.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yoshida, T., Kobayashi, K. & Watanabe, K. Respirometer by a piezo device and its application to triage. Artif Life Robotics 23, 146–151 (2018). https://doi.org/10.1007/s10015-017-0394-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10015-017-0394-x

Keywords

Navigation