Abstract
The expansion of power grid scale not only increases the transmission capacity, but also increases the probability of power plant facilities failure. The large scale of power grid and its high voltage make fault detection have heavy workload and high risk. In this paper, patrol robot, infrared imaging technology for detecting equipment faults and support vector machine (SVM) for identifying infrared image of faulty equipment were briefly introduced. Then, SVM for identifying infrared image of faulty equipment was simulated and analyzed with MATLAB software and compared with information entropy method. Then, patrol robot which applied two recognition methods in substation of X city power supply bureau were operated for one month. The results showed that the recognition accuracy of SVM was above 97% in the simulation experiment, which was significantly higher than that of information entropy method. In actual operation, the efficiency of patrol robot was higher than that of the traditional manual patrol, and the failure recognition rate of patrol robot which applied the two methods was close to the simulation results.





Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
Xiao P, Yu LX, Chen SH, Wang HP, Wang BH (2015) Design of a laser navigation system for substation inspection robot. Appl Mech Mater 713–715(385–386):711–714
Sun K, Fu C, Jia T, Liu J (2016), Simulation test system for substation patrol robot, 2016 4th international conference on applied robotics for the power industry (CARPI) IEEE.7745623
Su B, Zhang H, Meng H (2017) Development and implementation of a robotic inspection system for power substations. Ind Rob 44(3):333–342
Zhao ZB, Xu GZ, Qi YC, Pan DF (2016) An intelligent on-line inspection and warning system based on infrared image for transformer bushings. Recent Adv Electr Electron Eng (Formerly Recent Patents on Electrical and Electronic Engineering) 9(1):53–62
Gao Y, Zhao Y, Geng Y (2017) Super-resolution restoration method for infrared image of power line. J Jilin Univ 35(1):8–13
Chu X, Wang W, Yoon SC, Ni XZ, Heitschmidt GW (2017) Detection of aflatoxin B 1 (AFB 1) in individual maize kernels using short wave infrared (SWIR) hyperspectral imaging. Biosys Eng 157:13–23
Jian L, Tan T (2015) LS-SVM based substation circuit breakers maintenance scheduling optimization. Int J Electr Power Energy Syst 64:1251–1258
Gao J, Xu C, Zhang L, Liu S, Feng W, Xiong S, Tan S (2017), Infrared image change detection of substation equipment in power system using markov random field. 2017 international conference on computing intelligence and information system (CIIS). IEEE Computer Society 54
Acknowledgements
The research was supported by the “Shenzhen Science and Technology Innovation Committee Science and Technology Project (Project No.: JSGG20170824091941005, project name: Research and development of key technology of substation equipment automatic inspection system based on robot technology)”.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Zhao, X., Peng, Z. & Zhao, S. Substation electric power equipment detection based on patrol robots. Artif Life Robotics 25, 482–487 (2020). https://doi.org/10.1007/s10015-020-00604-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10015-020-00604-8