Abstract
Movement-based interaction has brought about new possibilities in healthcare environments. Concretely, rehabilitation therapies represent an adequate domain in which this kind of systems can produce significant benefits. In this context, the authors have developed SIVIRE, a movement-based interaction system whose main contributions are a virtual online editor of exercises with the capacity to adapt the rehabilitation to the patients’ conditions and evolution. During the development process, we have considered some aspects regarding the monitoring process to improve the quality and accuracy of the system, such as monitoring the patient’s postures, which is a critical procedure in order to properly correct and guide them. Specifically, this paper presents a descriptive study of three methods that address the monitoring process in a different way: the first using joint coordinates, the second based on bones coordinates and the last using the angles generated by the bones. Following the analysis of these three different mechanisms, the authors discuss the reason to identify the use of joint coordinates as the best technique to monitor patients in this kind of movement-based interaction systems. Such technique has been applied in the development of SIVIRE. Finally, we present the results of the evaluation of the system implemented with this monitoring mechanism. The outcomes prove that SIVIRE offers a reliable and useful tool to support rehabilitation therapies, both for patients and physiotherapists.











Similar content being viewed by others
Notes
Myo armband. Thalmic Labs Inc. https://www.myo.com/.
Leap Motion. Leap Motion Inc. https://www.leapmotion.com/.
References
Brooke, J.: SUS—A Quick and Dirty Usability Scale. Digital Equipment Co., Ltd, Reading (1996)
Fernández-Valls, J.A., Penichet, V.M., Lozano, M.D., Garrido, J.E.: Getting-up rehabilitation therapy supported by movement based interaction techniques. DYNA 82(193), 241–249 (2015). https://doi.org/10.15446/dyna.v82n193.53500ISSN0012-7353
Garrido, J.E., Marset, I., Penichet, V.M., Lozano, M.D., Fernández, J.A.: Automatic detection of falls and fainting. J. Univ. Comput. Sci. 19(8), 1105–1112 (2013). https://doi.org/10.3217/jucs-019-07
ISO/IEC 25062,: SQuaRE—Common Industry Format (CIF) for usability test reports. ISO (2006)
Khronos Group.: WebGL. OpenGL ES 2.0 for the Web. Retrieved from https://www.khronos.org/webgl
Lymberis, A.,Smart, A.: Wearables for remote health monitoring, from prevention to rehabilitation: current R&D, future challenges. In Proceedings of the 4th International IEEE EMBS Conference on Information Technology Applications in Biomedicine, pp. 272–275 (2003)
Navarro, J.E., Penichet, V.M., Lozano, M.D.: Movement-based interaction applied to physical rehabilitation therapies. J. Med. Internet Res. (JMIR) 16, 12 (2014)
RespondWell. Telerehabilitation Software. http://respondwell.com/. Accessed 01 May 2016]
Sugarman, H., Weisel-Eichler, A., Burstin, A., Brown, R.: Use of novel virtual reality system for the assessment and treatment of unilateral spatial neglect: a feasibility study. In Proceedings of the 2011 International Conference on Virtual Rehabilitation Zurich, Switzerland, June 27–29, 2011. New York: IEEE. doi: 10.1109/ICVR.2011.5971859
Virtualware Group. 2013. Virtual Rehab. http://virtualrehab.info/product/. Accessed 02 May 2016
Westhealth Institute. Reflexion Rehabilitation Measure Tool. http://www.westhealth.org/institute/our-priorities/reflexion. Accessed 01 May 2016
Acknowledgements
This work has been partially funded by project with reference UCTR150497 from the Castilla-La Mancha Regional Government: Junta de Comunidades de Castilla-La Mancha, Consejería de Empleo y Economía. We would also like to thank Tecon Solutions Informática S.L. for their collaboration on this application.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Garrido, J.E., Penichet, V.M.R., Lozano, M.D. et al. The use of joint coordinates to monitor patients in a movement-based interaction system. Univ Access Inf Soc 18, 3–16 (2019). https://doi.org/10.1007/s10209-017-0587-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10209-017-0587-z