Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based

  • Published:
Cluster Computing Aims and scope Submit manuscript

Abstract

Experts expect that even though peaceful use of nuclear power including nuclear power plant is less likely to contribute to average annual radiation exposure level, once accidents occur, it will spell a disaster. This paper is to manufacture a bismuth eco-friendly radiation shield which does not contain lead for providing medical support when national disaster and radioactive accident occur and compare and evaluate the characteristics of the shield and the definition of image by using glass dosimeter and finally to assess its usability. The fact that bismuth radiation shield with 0.5 mm and lead radiation shield with 0.5 mm showed an equal percentage of efficiency is showing that bismuth is suitable as a eco-friendly material replacing lead in the field of medical radiation. This result implies that the eco-friendly radiation shield which is lighter than lead radiation shield can be utilized in the field of medical radiation as a radiation shield decreasing radiation exposure level. It is advised to develop a light weight and eco-friendly radiation shield to reduce radiation exposure level in the field of medical radiation and to obtain optimal medical image.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Lee, Y.S., Lee, J.W., Lee, Y.J.: Development of the rocess mapping for the radiation safety management. J. Radiat. Prot. 38(3), 149–156 (2013)

    Article  Google Scholar 

  2. Kim, C.-G.: Spatial dose distribution and exposure dose during mammography. Indian J. Sci. Technol. 8(S8), 133–138 (2015)

    Article  Google Scholar 

  3. Nuclear, U.S.: Regulatory Commission. Final safety culture statement. NRC-2010-0282. Federal Register 76, 34773–34778 (2011)

  4. NCRP, Ionizing radiation exposures of the population of the United States, National Council on radiation protection and measurement, NCRP Publication 93, (1987)

  5. Jeon, M.-C., Han, M.-S., Lim, H.-S., Jang, J.-U., Yoo, S.-J., Seo, S.-Y., Kim, C.-G.: The analysis of doses and image at chest radiography using an active breathing coordinator (ABC) system. Clust. Comput. 18, 659–665 (2015)

    Article  Google Scholar 

  6. Seo, D., Jung, H., Sung, W.-K., Kim, S., Lee, S.: Development of Korean spine database and ontology for realizing \(e\)-Spine. Clust. Comput. 17, 1069–1080 (2014)

    Article  Google Scholar 

  7. Kim, C.-G.: The development of bismuth shielding to protect the thyroid gland in radiations environment. Indian J. Sci. Technol. 9(25), 1–6 (2016)

    Google Scholar 

  8. Suero, E.M., Hawi, N., Citak, M., Decker, S., Brandes, J., Meller, R., Krettek, C., Stübig, T.: Intraoperative imaging of the shoulder: a comparison of two- and three-dimensional imaging techniques. Technol. Health Care 23(2), 171–177 (2015)

    Google Scholar 

  9. Kim, C.-G.: Exposure dose reduction during lateral spine test with water filter. Technol. Health Care 24, 429–438 (2016)

    Article  Google Scholar 

  10. Marina, M., Dragan, J., Aleksandar, P.: Segmentation for the enhancement of microcalcifications in digital mammograms. Technol. Health Care 22(5), 701–715 (2014)

    Google Scholar 

  11. Youn-Soo, S., Ah-Hyeon, K., Ja-Eun, C., So-Youn, A.: Use of three-dimensional computed tomography images in dental care of children and adolescents in Korea. Technol. Health Care 22(3), 333–337 (2014)

    Google Scholar 

  12. Sang-Tae, K., Jung-Keun, C.: Monte Carlo simulation for correlation analysis of average glandular dose by breast thickness and glandular ratio in breast tissue. Technol. Health Care 22(3), 345–350 (2014)

    Google Scholar 

  13. Young-Cheol, J., Chung-Hwan, L., Chun-Yong, L., Hong-Ryang, J.: A study on the correlation between patients’physical characteristics and effective dose of liver computed tomography. Technol. Health Care 22(3), 403–408 (2014)

    Google Scholar 

  14. Jung, E.-Y., Kim, J., Chung, K.-Y., Kyun Park, D.: Mobile healthcare application with EMR interoperability for diabetes patients. Clust. Comput. 17, 871–880 (2014)

    Article  Google Scholar 

  15. Song, X., He, G., Zhang, Z., Long, T., Peng, Y., Wang, Z.: Visual attention model based mining area recognition on massive high-resolution remote sensing images. Clust. Comput. 18, 541–548 (2015)

    Article  Google Scholar 

  16. Kim, J.-K., Lee, J.-S., Park, D.-K., Lim, Y.-S., Lee, Y.-H., Jung, E.-Y.: Adaptive mining prediction model for content recommendation to coronary heart disease patients. Clust. Comput. 17, 881–891 (2014)

    Article  Google Scholar 

  17. S. C. Kim, M. H. Park, Development of radiation shielding sheet with environmentally-friendly materials; II: Evaluation of Barum, Tourmaline, silicon polymers in the radiation shielding sheet, J. Radiol. Sci. Vol. 34, No. 2, (2011)

  18. Kim, S.H., Kim, Y.J., Kwak, J.S.: Development and radiation shield effects of dose reduction fiber for scatter ray in CT exams. J. Korea Acad. Indus. Cooperation Soc. 14(4), 1871–1876 (2013)

    Article  Google Scholar 

  19. Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)

    Article  Google Scholar 

  20. Farzaneh, M.J.K., Shirin Shandiz, M., Vardian, M., Reza Deevband, M., Reza Kardan, M.: Evaluation of image quality and patient dose in conventional radiography examinations in radiology centers in sistan and baluchestan, Iran and comparing with that of international guidelines levels. Indian J. Sci. Technol. 4(11), 1429–1433 (2011)

    Google Scholar 

  21. Jung, M., Kweon, D., Kwon, S.: Effectiveness of bismuth shield to reduce eye lens radiation dose using the photoluminescence dosimetry in computed tomography. Radiotechnol. Sci. 32(3), 307–312 (2009)

    Google Scholar 

  22. Rah, J.-E., Hong, J.-Y., Kim, G.-Y., Kim, Y.-L., Shin, D.-O., Suh, T.-S.: A comparison of the dosimetric characteristics of a glass rod dosimeter and a themoluminescent dosimeter for mailed dosimeter. Radiat. Meas. 44, 18–23 (2009)

    Article  Google Scholar 

  23. Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)

    Article  Google Scholar 

  24. Kim, C.G.: Exposure dose reduction using Pb banding of own manufacturing. Soc. Dig. Policy Manag. 11(6), 269–273 (2013)

    Google Scholar 

  25. Kim, C.G.: Radiation dose reduction effectiveness of a male gonadal shield during 128-MDCT using glass detector. Soc. Dig. Policy Manag. 11(7), 237–242 (2013)

    Google Scholar 

  26. Kim, C.G.: Measurement dose of dental panoramagraphy using a radiophotoluminescent glass rod detector. Korea Acad. Indus. Cooperation J. 12(6), 2624–2628 (2011)

    Article  MathSciNet  Google Scholar 

  27. Jeong eun Ra: W.S Suh, D.O. Shin, H. S. Kim, T. S. Suh, Determination of out factors for the gamma-knife using a photoluminescence glass rod detector. Med. Phys. 18(1), 198–199 (2007)

  28. Kim, C.G.: Zirconia core inspection during radiation dose and image quality”. J. Converg. Inf. Technol. 8(13), 471–475 (2013)

    Google Scholar 

  29. Kang, J.-M., Lim, H., Yun, S.: A study for the mechanism of expression of individual creativity throughout the social learning platform in cluster computing environment (focus on scenario and data collection design). Clust. Comput. 18, 619–627 (2015)

    Article  Google Scholar 

  30. Barzegar, B., Esmaeelzadeh, H., Shirgahi, H.: A new method on resource management in grid computing systems based on QoS and semantics. Indian J. Sci. Technol. 4(11), 1416–1419 (2011)

    Google Scholar 

  31. Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)

    Article  Google Scholar 

  32. Kim, C.G.: The evaluation of the radiation dose and the image quality during MDCT using glass rod detector. Korea Soc. Dig. Policy and Manag. J. 10(2), 249–254 (2012)

    Google Scholar 

  33. Chan-Soo, P., Jong-Il, P., Kwang-Gi, K., Chang-No, C., Byung-Uk, A., Hwan-Jun, J.: Select this result for bulk action a quantitative evaluation of abdominal aorta aneurysm by CT images. Technol. Health Care 23(1), 37–45 (2015)

    Google Scholar 

  34. Yuexing, N., Haifeng, C., Jinyin, Y., Ning, L.: CT-guided satellite ganglion block for the treatment of prostatectomy pain in survivors of breast cancer. Technol. Health Care 23, 133–139 (2015)

    Article  Google Scholar 

  35. Youl-Hun, S.: Evaluation of relative speed of latent images in relation to changes in fading time and storage temperature of imaging plates in computed radiography systems. Technol. Health Care 22(3), 427–434 (2014)

    Google Scholar 

Download references

Acknowledgements

This research was supported by a Gimcheon University research Grants in 2015.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chang-Gyu Kim.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, SC., Seo, SY., Yu, JH. et al. Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based. Cluster Comput 21, 1109–1116 (2018). https://doi.org/10.1007/s10586-017-0750-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10586-017-0750-6

Keywords

Navigation