Abstract
The massive number of medical images produced by fluoroscopic and other conventional diagnostic imaging devices demand a considerable amount of space for data storage. This paper proposes an effective method for lossless compression of fluoroscopic images. The main contribution in this paper is the extraction of the regions of interest (ROI) in fluoroscopic images using appropriate shapes. The extracted ROI is then effectively compressed using customized correlation and the combination of Run Length and Huffman coding, to increase compression ratio. The experimental results achieved show that the proposed method is able to improve the compression ratio by 400 % as compared to that of traditional methods.








Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
Bairagi, V., and Sapkal, A., Automated region-based hybrid compression for digital imaging and communications in medicine magnetic resonance imaging images for telemedicine applications. IET Sci. Meas. Technol. 6(4):247–253, 2012.
Kumar, N., and Kamargaonkar, C., A survey on various medical image compression techniques. Int. J. Sci. Eng. Technol. Res. 2(2):501–506, 2013.
Ukrit, M., Umamageswari, A., and Suresh, G., A survey on lossless compression for medical images. Int. J. Comput. Appl. 31(8):47–50, 2011.
Choong, M., Logeswaran, R., and Bister, M., Improving diagnostic quality of MR images through controlled lossy compression using SPIHT. J. Med. Syst. 30(3):139–143, 2006.
Mei-Yen, C., Chien-Tsai, L., Ying-Chou, S., et al, Design and evaluation of a DICOM compliant video fluoroscopy imaging system. In: Proceeding of IEEE 9th International Conference on Health Networking Application and Services: Taipei, pp. 248–251, 2007.
Russakoff, D., Rohlfing, T., and Maurer, C., Fuzzy segmentation of X-ray fluoroscopy images. Proc. SPIE 4684:146–154, 2002.
Doukas, C., and Maglogiannis, I., Region of interest coding techniques for medical image compression. IEEE Eng. Med. Biol. Mag. 26(5):29–35, 2007.
Zhang, Q., Xiao, H., Extracting regions of interests in biomedical images. IEEE International Seminar on Future Biomedical Information Engineering, pp. 3–6, 2008.
Teng, W., and Chang, P., Identifying regions of interest of medical images using self-organizing map. J. Med. Syst. 36:2761–2768, 2011.
Faisal, A., Parveen, S., and Badsha, S., Assisted diagnostic systems in tumor radiography. J. Med. Syst. 37:9938, 2013.
Špelič, D., and Žalik, B., Lossless compression of threshold-segmented medical images. J. Med. Syst. 36:2349–2357, 2012.
Song, T., and Shimamoto, T., Reference frame data compression method for H.264/AVC. IEICE Electron. Expr. 4(3):121–126, 2007.
Núñez, J., and Jones, S., Run-length coding extensions for high performance hardware data compression. IEE Proc. Comp. Digit. Tech. 150(6):387–395, 2003.
Norani, M., and Tehranipour, M., RL-Huffman encoding for test compression and power reduction in scan applications. ACM Trans. 10(1):91–115, 2005.
Sunder, R., Eswaran, C., Sriraam, N., Performance evaluation of 3-D transforms for medical image compression. IEEE International Conference, Electro Information Technology, 6 pp. -6, 2005.
Arif, A., Mansor, S., Logeswaran, R., and Abdul Karim, H., Lossless compression of fluoroscopy medical images using correlation. J. Asian Sci. Res. 11(2):718–723, 2012.
Sameh, A., Mansor, S., Logeswaran, R., Abdul Karim, H., Segmentation and compression of pharynx and esophagus fluoroscopic images. IEEE International Conference on Signal and Image Processing Applications (ICSIPA), 2013.
Arif, A., Mansor, S., Logeswaran, R., and Abdul Karim, H., Lossless compression of pharynx and esophagus in fluoroscopy medical images. Int. J. Biosci. Biochem. Bioinforma. 3(5):483–487, 2013.
Arif, A., Mansor, S., Logeswaran, R., Abdul Karim, H., Lossless compression of fluoroscopy medical images using correlation and the combination of Run Length and Huffman coding. IEEE International Conference on Biomedical Engineering & Science (IECBES), pp. 759–762, 2012.
Arif, A., Mansor, S., Logeswaran, R., Abdul Karim, H., Combined bilateral and anisotropic-diffusion filters for medical image denoising. IEEE Student Conference for research and development (SCOReD), pp. 420–424, 2011.
Acknowledgments
The authors would like to thank Dr. Sharifah Mastura Syed Abu Bakar (Head Radiology Department), Khatijah Ali (Radiographer) and Mr Ang Kim Liong (Clinical Research Centre) at Serdang Hospital, Malaysia, for their assistance and collaboration in undertaking this work.
Author information
Authors and Affiliations
Corresponding author
Additional information
This article is part of the Topical Collection on Systems-Level Quality Improvement
Rights and permissions
About this article
Cite this article
Arif, A.S., Mansor, S., Logeswaran, R. et al. Auto-shape Lossless Compression of Pharynx and Esophagus Fluoroscopic Images. J Med Syst 39, 5 (2015). https://doi.org/10.1007/s10916-015-0200-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10916-015-0200-z