This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  1. Wang, Y., Yu, K., Wang, D., Zhao, C., Wang, L. and Wang, P., “Multi-Model Diagnosis Method for Lung Cancer based on MOS-SAW Breath Detecting e-Nose,” in Proceedings of The 14th International Symposium on Olfaction and Electronic Nose, 2011.

  2. Wang, Y., Hu, Y., Wang, D., Yu, K., Wang, L., Zou, Y., Zhao, C., Zhang, X., Wang, P., and Ying, K., The analysis of volatile organic compounds biomarkers for lung cancer in exhaled breath, tissues and cell lines. Cancer. Biomark. 11:129–137, 2012.

    Google Scholar 

  3. Cao, H., Li, H., Stocco, L., and Leung, V. C. M., Wireless three-pad ECG system: challenges, design, and evaluations. Commun. Net. J. 13:113–124, 2011.

    Article  Google Scholar 

  4. Einthoven, W., Weiteres ueber das elektrokardiogram. Pflueger Arch. ges. Physiol. 122:517–584, 1908.

    Article  Google Scholar 

  5. Wilson, F. N., Johnston, F. D., Rosenbaum, F. F., Erlanger, H., Kossmann, C. E., Hecht, H., Cotrim, N., Oliveira, R. M. d., Scarsi, R. and Barker, P. S., “The precordial electrocardiogram,” AHJ, vol. 27, pp. 19-85, 1944.

  6. Mason, R. E., and Likar, I., A new system of multiple-lead exercise electrocardiography. AHJ. 71:196–205, 1966.

    Article  Google Scholar 

  7. Dower, G. E., Yakush, A., Nazzal, S. B., Jutzy, R. V., and Ruiz, C. E., Deriving the 12-lead electrocardiogram from four (EASI) electrodes. J. Electrocardiol. 21:182–187, 1988.

    Article  Google Scholar 

  8. Munshi, M., Xu, X., Zou, X., Soetiono, E., Teo, C. S. and Lian, Y., “Wireless ECG plaster for body sensor network,” in Proceedings of ISSS-MDBS 2008, 2008.

  9. Masse, F., Penders, J., Serteyn, A., Bussel, M. van and Arends, J., “Miniaturized wireless ECG-monitor for real-time detection of epileptic seizures,” in Proceedings of Wireless Health 2010, 2010.

  10. Altini, M., Polito, S., Penders, J., Kim, H., Helleputte, N. Van, Kim, S. and Yazicioglu, F., “An ECG patch combining a customized ultra-low-power ECG SoC with bluetooth low energy for long term ambulatory monitoring,” in Proceedings of the 2nd Conference on Wireless Health, 2011.

  11. Hoekema, R., Uijen, G., and van Oosterom, A., On selecting a body surface mapping procedure. J. Electrocardiol. 32:93–101, 1999.

    Article  Google Scholar 

  12. Torfs, Yazicioglu, T. R., Kim, S., Kim, H., Hoof, C. Van, Buxi, D., Romero, I. a. W. J., Masse, F. and Penders, J., “Ultra low power wireless ECG system with beat detection and real time impedance measurement,” in Proceedings of IEEE BioCAS 2010 Conference, 2010.

  13. Gomez-Clapers, J., and Casanella, R., A fast and easy-to-use ECG acquisition and heart rate monitoring system using a wireless steering wheel. Sens. J. IEEE. 12:610–616, 2012.

    Article  Google Scholar 

  14. Kim, S., and Eom, D., Link-state-estimation-based transmission power control in wireless body area networks. IEEE J-BHI. 18:1294–1302, 2014.

    Google Scholar 

  15. Wang, Y., Wunderlich, R. and Heinen, S., “Design and Evaluation of a Novel Wireless Reconstructed 3-Lead ECG Monitoring System,” in Proceedings of IEEE BioCAS 2013 Conference, 2013.

  16. Ambu® BlueSensor M. Ambu Inc., 2013.

  17. Wang. Y., Wunderlich. R. and Heinen. S., “A low noise wearable wireless ECG system with body motion cancellation for long term homecare,” in Proceedings of IEEE Healthcom 2013 Conference, 2013.

  18. A true system-on-chip solution for 2.4-GHz IEEE 802.15.4 and ZigBee applications. Texas Instruments Inc., 2011.

  19. Andersen, A., 2.4 GHz inverted F antenna. Texas Instruments Inc., 2008.

  20. USB 4-BIT SPI/FT1248 IC FT220X. Future Technology Devices International Ltd., 2014.

  21. Xiao, S., Dhamdhere, A., Sivaraman, V., and Burdett, A., Transmission power control in body area sensor networks for healthcare monitoring. IEEE J-SAC. 27:37–48, 2009.

    Google Scholar 

  22. Pan, J., and Tompkins, W. J., A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. BME-32:230–236, 1985.

    Article  Google Scholar 

  23. Burns, A., Doheny, E., Greene, B., Foran, T., Leahy, D., O’Donovan, K. and McGrath, M., “SHIMMER™: an extensible platform for physiological signal capture,” in Proceedings of Annual International Conference of IEEE EMBC 2010, 2010.

  24. Gaxiola-Sosa, J., Mohsin, N., Palliyali, A., Tafreshi, R. and Entesari, K., “A portable 12-lead ECG wireless medical system for continuous cardiac-activity monitoring,” in Proceedings of MECBME 2014, 2014.

  25. Gao, H., Duan, X., Guo, X., Huang, A. and Jiao, B., “Design and tests of a smartphones-based multi-lead ECG monitoring system,” in Proceedings of Annual International Conference of IEEE EMBC 2013, 2013.

  26. Tan, T.-H., Chang, C.-S., Huang, Y.-F., Chen, Y.-F., and Lee, C., Development of a portable linux-based ECG measurement and monitoring system. J. Med. Syst. 35:559–569, 2011.

    Article  Google Scholar 

  27. Winokur, E., Delano, M., and Sodini, C., A wearable cardiac monitor for long-term data acquisition and analysis. IEEE Trans. Biomed. Eng. 60:189–192, 2013.

    Article  Google Scholar 

  28. Chen, H., Wu, W., and Lee, J., A WBAN-based real-time electroencephalogram monitoring system: design and implementation. J. Med. Syst. 34:303–311, 2010.

    Article  Google Scholar 

  29. Fensli, R., Dale, J., O’Reilly, P., O’Donoghue, J., Sammon, D., and Gundersen, T., Towards improved healthcare performance: examining technological possibilities and patient satisfaction with wireless body area networks. J. Med. Syst. 34:767–775, 2010.

    Article  Google Scholar 

  30. Pantazis, N., and Vergados, D., A survey on power control issues in wireless sensor networks. IEEE Commun. Surv. Tutor. 9:86–107, 2007.

    Article  Google Scholar 

  31. Zhou, G., He, T., Krishnamurthy, S. and Stankovic, J. A., “Impact of radio irregularity on wireless sensor networks,” in Proceedings of MobiSys 2004, 2004.

  32. Zhao, J. and Govindan, R., “Understanding packet delivery performance in dense wireless sensor networks,” in Proceedings of the 1st International Conference on Embedded Networked Sensor Systems, 2003.

  33. Malmivuo, J., and Plonsey, R., Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New York, 1995.

    Book  Google Scholar 

  34. Yanowitz, F. G., Introduction to ECG interpretation V8.0. Eccles Health Sciences Library University of Utah, Salt Lake City, 2012.

    Google Scholar 

  35. Welinder, A., Sörnmo, L., Field, D. Q., Feldman, C. L., Pettersson, J., Wagner, G. S., and Pahlm, O., Comparison of signal quality between easy and Mason-Likar 12-Lead electrocardiograms during physical activity. AJCC. 13:228–234, 2004.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yishan Wang.

Additional information

This article is part of the Topical Collection on Mobile Systems

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, Y., Doleschel, S., Wunderlich, R. et al. A Wearable Wireless ECG Monitoring System With Dynamic Transmission Power Control for Long-Term Homecare. J Med Syst 39, 35 (2015). https://doi.org/10.1007/s10916-015-0223-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10916-015-0223-5

Keywords

Navigation