Abstract
Near-infrared optical tracking devices, which are important components of surgical navigation systems, need to be calibrated for effective tracking. The calibration results has a direct influence on the tracking accuracy of an entire system. Therefore, the study of calibration techniques is of theoretical significance and practical value. In the present work, a systematic calibration method based on movable plates is established, which analyzes existing calibration theories and implements methods using calibration reference objects. First, the distortion model of near-infrared cameras (NICs) is analyzed in the implementation of this method. Second, the calibration images from different positions and orientations are used to establish the required linear equations. The initial values of the NIC parameters are calculated with the direct linear transformation method. Finally, the accurate internal and external parameters of the NICs are obtained by conducting nonlinear optimization. Analysis results show that the relative errors of the left and right NICs in the tracking system are 0.244 and 0.282 % for the focal lengths and 0.735 and 1.111 % for the principal points, respectively. The image residuals of the left and right image sets are both less than 0.01 pixel. The standard error of the calibration result is lower than 1, and the measurement error of the tracking system is less than 0.3 mm. The experimental data show that the proposed method of calibrating NICs is effective and can generate favorable calibration results.
Similar content being viewed by others
References
Song, L. M., Wang, M. P., Lu, L., et al., High precision camera calibration in vision measurement. Opt. Laser Technol. 39(7):1413–1420, 2007.
Meng, X., and Hu, Z., A new easy camera calibration technique based on circular points. Pattern Recogn. 36(5):1155–1164, 2003.
Caprile, B., and Torre, V., Using vanishing points for camera calibration. Int. J. Comput. Vis. 4(2):127–139, 1990.
Maybank, S. J., and Faugeras, O. D., A theory of self-calibration of a moving camera. Int. J. Comput. Vis. 8(2):123–151, 1992.
Hartley, R., Projective reconstruction and invariants from multiple images. IEEE Trans. Pattern Anal. 16(10):1036–1041, 1994.
Hallert, B., Notes on calibration of cameras and photographs in photogrammetry. Photogrammetria 23(5):163–178, 1968.
Faig, W., Calibration of close-range photogrammetric systems: Mathematical formulation. Photogramm. Eng. Rem. Sens. 41(12):1479–1486, 1975.
Tsai, R. Y., A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE J. Robot. Autom. 3(4):323–344, 1987.
Lenz, R. K., and Tsai, R. Y., Techniques for calibration of the scale factor and image center for high accuracy 3-D machine vision metrology. IEEE Trans. Pattern Anal. 10(5):713–720, 1988.
Weng, J., Cohen, P., and Herniou, M., Camera calibration with distortion models and accuracy evaluation. IEEE Trans. Pattern Anal. 14(10):965–980, 1992.
Zhang, Z., A flexible new technique for camera calibration. IEEE Trans. Pattern Anal. 22(11):1330–1334, 2000.
Haitao, N., and Xunjie, Z., New method of camera calibration based on checkerboard [J]. Infrared Laser Eng. 40(1):133–137, 2011.
Triggs, B., Autocalibration and the absolute quadric. In: Computer Vision and Pattern Recognition, IEEE Comp. Soc. Conf. 609–614, 1997.
Hu, Z.-y., and Wu, F.-c., A review on some active vision based camera calibration techniques. Chin J. Comp. 25(11):1149–1156, 2002.
Ju, H., Wei, Y., and Ming, Y., A self-calibration technique based on the geometry property of the vanish point. Acta Opt. Sin. 30(2):465–472, 2010.
Yang, R., Cheng, S., and Chen, Y., Flexible and accurate implementation of a binocular structured light system. Opt. Lasers Eng. 46(5):373–379, 2008.
Wen, X.-y., Liu, S.-j., Yang, R.-q., et al., Pattern design and realization for calibrating near infrared camera in surgical navigation. Optoelectron. Lett. 8:409–413, 2012.
Abdel-Aziz, Y., and Karara, H., Direct linear transformation into object space coordinates in close-range photogrammetry. In: Proc. Symp. Close-Range Photogrammetry. Urbana-Champaign 1–18, 1971.
Faugeras, O., and Toscani, G., Camera calibration for 3D computer vision. In: Proceedings of International Workshop on Machine Vision and Machine Intelligence, Tokyo, Japan, 1987.
Ma, W., Zheng, Y., and Liu, Y., Camera calibration using two concentric circles: Linear approach. Opt. Eng. 48(5):053602-1–053602-6, 2009.
Draréni, J., Roy, S., and Sturm, P., Plane-based calibration for linear cameras. Int. J. Comput. Vis 91(2):146–156, 2011.
Weng, J., Cohen, P., and Herniou, M., Calibration of stereo cameras using a non-linear distortion model [CCD sensory]. 10th International Conference in Pattern Recognition, 246–253, 1990.
Acknowledgments
This research was funded by the National Natural Science Foundation of China under Grant No.61505037, the State Scholarship Fund under Grant CSC NO.201408440326, the Pearl River S&T Nova Program of Guangzhou under Grant No.2014 J2200049 and No.201506010035, the Guangdong Provincial Science and Technology Program under Grant No.2013B090600057, No.2014A020215006 and 2014A020212657, the Fundamental Research Funds for the Central Universities under Grant No.2014ZG003D, the Natural Scientific Foundation of Guangxi under Grant No.2015GXNSFBA139259.
Author information
Authors and Affiliations
Corresponding author
Additional information
This article is part of the Topical Collection on Systems-Level Quality Improvement
Rights and permissions
About this article
Cite this article
Cai, K., Yang, R., Lin, Q. et al. Near-Infrared Camera Calibration for Optical Surgical Navigation. J Med Syst 40, 67 (2016). https://doi.org/10.1007/s10916-015-0427-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10916-015-0427-8