Skip to main content
Log in

Silicon-based microelectrode arrays for stimulation and signal recording of in vitro cultured neurons

  • Research Papers
  • Published:
Science China Information Sciences Aims and scope Submit manuscript

Abstract

Microelectrode arrays (MEAs) for stimulation and signal recording of in vitro cultured neurons are presented. Each MEA is composed of 60 independent electrodes with 59 working ones and one reference one. These electrodes are divided into 30 pairs. Through each pair of electrodes, four independent states can be realized to define the accessing modes of neurons cultured on the surface of the electrodes. A total MEA covers an area of 10 mm×10 mm. MEAs are fabricated in a silicon-based semiconductor process. An implemented MEA is bonded on a specially designed printed-circuit-board (PCB) and surrounded by a culture chamber. An impedance measurement has been made to verify the electrical characteristics of MEAs. The surface was modified to enhance the biocompatibility. A series of PC12 cells culture experiments validates the effectiveness of the modification. An extracellular signal recording experiment with acetylcholine (Ach) as a stimulant has been carried out, and the results show the feasibility of MEAs for extracellular action potential recording. Extracellular electrical stimulation and recording experiments have been carried out too. They indicate that MEAs can be used for extracellular stimulation, recording, simultaneous stimulation and recording, and isolation of PC12 cells network cultured in vitro.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hoag H, Neuroengineering: Remot control. Nature, 2003, 423: 796–798

    Article  Google Scholar 

  2. Eversmann B, Jenkner M, Hofmann F, et al. A 128 × 128 CMOS biosensor array for extracellular recording of neural activity. IEEE J Solid State Circuit, 2003, 38: 2306–2317

    Article  Google Scholar 

  3. Heer F, Hafizovic S, Franks W, et al. CMOS microelectrode array for bidirectional interaction with neuronal networks. IEEE J Solid State Circuits, 2006, 41: 1620–1629

    Article  Google Scholar 

  4. Xiang G X, Pan L B, Huang L H, et al. Microelectrode array-based system for neuropharmacological applications with cortical neurons cultured in vitro. Biosens Bioelectron, 2007, 22: 2478–2484

    Article  Google Scholar 

  5. Levitan I B, Kaczmarek L K. The neuron cell and molecular biology. New York: Oxford University Press, 1997. 168–169

    Google Scholar 

  6. Neher E, Sakmann B. Single-channel currents recorded from membrane of denervated frog muscle fibres. Nature, 1976, 260: 799–802

    Article  Google Scholar 

  7. Cole K. Dynamic electrical characteristics of the squid axon membrane. Arch Sci Physiol, 1968, 3: 253–258

    Google Scholar 

  8. Thomas C A, Springer P A, Loeb G E, et al. A miniature microelectrode array to monitor the bioelectrical activity of cultured cells. Exp Cell Res, 1972, 74: 61–66

    Article  Google Scholar 

  9. Gross G W, Rieske E, Kreutzberg G W, et al. A new fixedarray multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro. Neurosci Lett, 1977, 6: 101–105

    Article  Google Scholar 

  10. Pine J. Recording action potentials from cultured neurons with extracellular microcircuit electrodes. J Neurosci Methods, 1980, 2: 19–31

    Article  Google Scholar 

  11. Johnstone A F M, Gross G W, Weiss D G, et al. Microelectrode arrays: A physiologically based neurotoxicity testing platform for the 21st century. NeuroToxicology, 2010, 31: 331–350

    Article  Google Scholar 

  12. Liu Q J, Ye W W, Xiao L D, et al. Extracellular potentials recording in intact olfactory epithelium by microelectrode array for a bioelectronic nose. Biosens Bioelectron, 2010, 25: 2212–2217

    Article  Google Scholar 

  13. Hill A J, Jones N A, Williams C M, et al. Development of multi-electrode array screening for anticonvulsants in acute rat brain slices. J Neurosci Meth, 2010, 185: 246–256

    Article  Google Scholar 

  14. Berdondini L, Massobrio P, Chiappalone M, et al. Extracellular recordings from locally dense microelectrode arrays coupled to dissociated cortical cultures. J Neurosci Meth, 2009, 177: 386–396

    Article  Google Scholar 

  15. Gullo F, Maffezzoli A, Dossi E, et al. Short-latency cross- and autocorrelation identify clusters of interacting cortical neurons recorded from multi-electrode array. J Neurosci Meth, 2009, 181: 186–198

    Article  Google Scholar 

  16. Heer F, Franks W, Blau A, et al. CMOS microelectrode array for the monitoring of electrogenic cells, Biosens Bioelectron, 2004, 20: 358–386

    Article  Google Scholar 

  17. Frey U, Heer F, Pedron R, et al. An 11k-electrode 126-channel high-density microelectrode array to interact with electrogenic cells. In: IEEE International on Solid-State Circuits Conference, San Francisco, 2007, 158–160

  18. Guillemaud R., Bêche J F, Billoint O, et al. A Multi-channel platform for recording and stimulation of large neuronal structures. IRBM, 2009, 30: 226–233

    Article  Google Scholar 

  19. Pan H X, Lü X Y, Wang Z G, et al, Microelectrode array for detecting electrical activities of neuron assemble. J Southeast University (Natural Science Edition) (in Chinese), 2009, 39: 468–472

    Google Scholar 

  20. Chen C H, Yao D J, Tseng S H, et al. Micro-multi-probe electrode array to measure neural signals. Biosens Bioelectron, 2009, 24: 1911–1917

    Article  Google Scholar 

  21. Xu G X, Ye X S, Qin L F, et al. Cell-based biosensors based on light-addressable potentiometric sensors for single cell monitoring. Biosens Bioelectron, 2005, 20: 1757–1763

    Article  Google Scholar 

  22. Yao H, Ding F Z, Liu A S, et al. Detecting physiological parameters of hippocampal neurons cultured in vitro and the monitoring the effect of neurotransmitter. Chin J Appl Physiol, 1994, 10: 183–185

    Google Scholar 

  23. Lin J H, Wu X M, Huang P S, et al. Development of silicon-based microelectrode array, Sci China Ser E-Tech Sci, 2009, 25: 2391–2395

    Article  Google Scholar 

  24. Norlin P, Kindlundh M, Mouroux A, et al. A 32-site neural recording probe fabricated by DRIE of SOI substrates. J Micromech Microeng, 2002, 12: 414–419

    Article  Google Scholar 

  25. Yu H, Cai H, Zhang W, et al. A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential. Biosens Bioelectron, 2009, 24: 1462–1468

    Article  Google Scholar 

  26. Sprössler C, Denyer M, Britland S, et al. Electrical recordings from rat cardiac muscle cells using field-effect transistors, Phys Rev E, 1999, 60: 2171–2176

    Article  Google Scholar 

  27. Yeung C K, Ingebrandt S, Krause M, et al. Validation of the use of field effect transistors for extracellular signal recording in pharmacyological bioassays. J Pharmacol Toxicol Methods, 2001, 45: 207–214

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to XiaoYing Lü or ZhiGong Wang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pan, H., Lü, X., Wang, Z. et al. Silicon-based microelectrode arrays for stimulation and signal recording of in vitro cultured neurons. Sci. China Inf. Sci. 54, 2199–2208 (2011). https://doi.org/10.1007/s11432-011-4384-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11432-011-4384-7

Keywords

Navigation