Integrated physiological flow simulator and pulse sequence monitoring system for MRI

  • Technical Note
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

A compact flow simulator for generating accurate pulsatile flow in a clinical magnetic resonance imaging (MRI) environment has been developed and integrated with a data acquisition (DAQ) system for recording scanner system activity and physiological waveforms. The flow simulator is relatively inexpensive, easy to construct and is controlled from a standard PC. The flow simulator is robust to repeated disassembly and reassembly (normalised cross-correlation 0.97) and generates accurate pulsatile flow (normalised cross-correlation 0.94). The DAQ system was used to monitor a standard MRI pulse sequence used in MR angiography and latent delays in the scanner gating subsystem.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

References

  1. Foo TK, Bernstein MA, Aisen AM, Hernandex RJ, Collick BD, Bernstein T (1995) Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repitition time excitation with fast cardiac techniques. Radiology 195:471–478

    Google Scholar 

  2. Frayne R, Holdsworth DW, Gowman LM, Rickey DW, Drangova M, Fenster A, Rutt BK (1992) Computer-controlled flow simulator for MR flow studies. J Magn Reson Imaging 2:605–612

    Article  Google Scholar 

  3. Frayne R, Steinman DA, Ethier CR, Rutt BK (1995) Accuracy of MR phase contrast velocity measurements for unsteady flow. J Magn Reson Imaging 5:428–431

    Article  Google Scholar 

  4. Hennig J, Nauerth A, Friedburg H (1986) RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 3:823–833

    Article  Google Scholar 

  5. Hoskins PR, Anderson T, McDicken WN (1989) A computer controlled flow phantom for generation of physiological Doppler waveforms. Phys Med Biol 34:1709–1717

    Article  Google Scholar 

  6. Lomas DJ, Graves MJ, Black RT, Joubert I (2004) Interactive MRA using ungated single-shot half-Fourier projection RARE. Proc Intl Soc Mag Reson Med 11:1944

    Google Scholar 

  7. Macgowan CK, Kellenberger CJ, Detsky JS, Roman K, Yoo S (2005) Real-time Fourier velocity encoding: an in vivo evaluation. J Magn Reson Imaging 21:297–304

    Article  Google Scholar 

  8. Miyazaki M, Tateishi F, Sugiura S, Machida Y, Kassai Y, Abe H (1998) Fresh blood imaging at 0.5T: natural blood contrast 3D MRA within single breathhold. Proc Intl Soc Mag Reson Med 6:780

    Google Scholar 

  9. Pelc NJ, Herfkens RJ, Shimakawa A, Enzmann DR (1991) Phase contrast cine magnetic resonance imaging. Magn Reson Q 7:229–254

    Google Scholar 

  10. Petersen JN (1984) Digitally controlled system for reproducing blood flow waveforms in vitro. Med Biol Eng Comput 22:277–280

    Article  Google Scholar 

  11. Plewes DB, Urchuk SN, Kim S, Soutar I (1995) An MR compatible flow simulator for intravascular pressure simulation. Med Phys 22:1111–1115

    Article  Google Scholar 

  12. Robertson MB, Kohler U, Hoskins PR, Marshall I (2001) Quantitative analysis of PC MRI velocity maps: pulsatile flow in cylindrical vessels. Magn Reson Imaging 19:685–695

    Article  Google Scholar 

  13. Smith RF, Rutt BK, Holdsworth DW (1999) Anthropomorphic carotid bifurcation phantom for MRI applications. J Magn Reson Imaging 10:533–544

    Article  Google Scholar 

  14. Summers PE, Holdsworth DW, Nikolov HN, Rutt BK, Drangova M (2005) Multisite trial of MR flow measurement: phantom and protocol design. J Magn Reson Imaging 21:620–631

    Article  Google Scholar 

Download references

Acknowledgments

This work is supported by Addenbrooke’s Charitable Trust. The authors are grateful to the MRIS Unit and Department of Clinical Engineering at Addenbrooke’s Hospital, and Chris Macgowan for his comments on our flow simulation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pauline Wong.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wong, P., Graves, M.J. & Lomas, D.J. Integrated physiological flow simulator and pulse sequence monitoring system for MRI. Med Biol Eng Comput 46, 399–406 (2008). https://doi.org/10.1007/s11517-008-0319-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-008-0319-x

Keywords

Navigation