Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians

  • Technical Note
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Analysis of the contour of the blood volume pulse (VP) has become important because it contains much information about cardiovascular activity. Traditionally, pulse contour analysis requires first or higher derivatives to be calculated. This paper describes a novel algorithm for analysing simultaneously measured ear and finger photoplethysmography (PPG) signals. The algorithm separates the systolic wave and the diastolic wave of the VP and fits each of them with the sum of two Gaussian functions. The VP was obtained from PPG signals taken from 40 healthy subjects at each heartbeat cycle. From the evaluated VP, time values of the direct wave and three reflected waves were calculated, as well as the augmentation index (AI) and the reflection index (RI). The evaluated parameters were compared with those that were obtained by the derivative method, and it was demonstrated that the new method can be used to analyze VP waveforms.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

References

  1. Allen J, Murray A (2002) Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes. J Hum Hypertens 16:711–717. doi:10.1038/sj.jhh.1001478

    Article  Google Scholar 

  2. Bortolotto LA, Blacher J, Kondo T, Takazawa K, Safar ME (2000) Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. Am J Hypertens 13:165–171. doi:10.1016/S0895-7061(99)00192-2

    Article  Google Scholar 

  3. Foo JY, Wilson SJ (2006) A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states. Med Biol Eng Comput 44(1–2):140–145. doi:10.1007/s11517-005-0008-y

    Article  Google Scholar 

  4. Imanaga I, Hara H, Koyanagi S, Tanaka K (1998) Correlation between wave components of the second derivative of the plethysmogram and arterial distensibility. Jpn Heart J 39:775–784

    Google Scholar 

  5. Karamanoglu M (1997) A system for analysis arterial blood pressure waveforms in humans. Comput Biomed Res 30:244–255. doi:10.1006/cbmr.1997.1450

    Article  Google Scholar 

  6. Laurent S, Cockcroft J, Bortel LV, Boutouyrie P, Giannattasio C, Hayoz D et al (2007) Abridged version of the expert consensus document on arterial stiffness. Artery Res 1:2–12. doi:10.1016/j.artres.2007.03.003

    Article  Google Scholar 

  7. Millaseau SC, Kelly RP, Ritter JM, Chowienczyk PJ (2002) Determination of age-related increases in large artery stiffness by digital pulse contour analysis. Clin Sci 103:371–377

    Google Scholar 

  8. Millaseau SC, Ritter JM, Takazawa K, Chowienczyk PJ (2006) Contour analysis of the photoplethysmographic pulse measured at the finger. J Hypertens 24:1449–1456. doi:10.1097/01.hjh.0000239277.05068.87

    Article  Google Scholar 

  9. Takazawa K, Tanaka N, Fujita M, Matsuoka O, Saiki T, Aikawa M et al (1998) Assessment of vascoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension 32:365–370

    Google Scholar 

  10. Talts J, Raamat R, Jagomägi K (2006) Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship. Med Biol Eng Comput 44(9):829–834. doi:10.1007/s11517-006-0090-9

    Article  Google Scholar 

  11. Westerhof N, Stergiopulos N, Noble MNM (2005) Snapshots of hemodynamics. Springer 15:69–70

    Google Scholar 

Download references

Acknowledgment

This study was supported by European Social Fund.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Uldis Rubins.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rubins, U. Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians. Med Biol Eng Comput 46, 1271–1276 (2008). https://doi.org/10.1007/s11517-008-0406-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-008-0406-z

Keywords

Navigation