In this article, we evaluated a planar microwave applicator for in vivo superficial hyperthermia treatments on small tumors in the mouse mimicking treatments for human neoplasms. The design of the applicator, was challenged by the small dimensions of the tumors and unwanted diffusion of heating in the tumor-bearing animals. The required solution was to limit the penetration of microwaves in the depth of the tissue maintaining the full efficacy of hyperthermia. The study was firstly performed by computer simulations of SAR distribution inside a flat homogeneous phantom, considering various thicknesses of the integrated water bolus. Simulations, validated by the measurements, were also used to evaluate the impedance matching. Further tests were performed on homogeneous agar phantom to simulate the temperature distribution in the biological tissue and to preliminary assess the possible modality and schedule of microwave hyperthermia delivery. The in vivo experiments showed the evidence of direct microwave-induced heating and damage of the melanoma tissue in a range of penetration coherent both with computer simulations and phantom studies. The described approach appears perspective for designing limited-microwave-delivery applicators tailored for treatments of human superficial tumors and pre-tumoral lesions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Novák P, Moros EG, Parry JJ, Rogers BE, Myerson RJ, Zeug A, Locke JE, Rossin R, Straube WL, Singh AK (2005) Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours. Phys Med Biol 50:5127–5139

    Article  Google Scholar 

  2. Samaras T, Van Rhoon GC, Sahalos JN (2002) Theoretical investigation of measurement procedures for the quality assurance of superficial hyperthermia applicators. Int J Hyperthermia 18:416–425

    Article  Google Scholar 

  3. Van der Gaag ML, De Bruijne M, Samaras T, Van der Zee J, Van Rhoon GC (2006) Development of a guideline for the water bolus temperature in superficial hyperthermia. Int J Hyperthermia 22:637–656

    Google Scholar 

  4. Hand JW, Lagendijk JJW, Bach Andersen J, Bolomey JC (1989) Quality assurance guidelines for ESHO protocols. Int J Hyperthermia 5:421–428

    Article  Google Scholar 

  5. van Rhoon GC, Rietveld PJ, van der Zee J (1998) A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia. Int J Hyperthermia 14:13–27

    Article  Google Scholar 

  6. Vrba J, Franconi C, Montecchia F, Vannucci I (1993) Evanescent-mode applicators (EMA) for superficial and subcutaneous hyperthermia. IEEE Trans Biomed Eng 40:397–407

    Article  Google Scholar 

  7. Dvorak SL, Aziz DJ (1995) Numerical analysis of printed strip dipole hyperthermia applicators. IEEE Trans Microwave Theory Tech 43:1502–1507. doi:DOI:10.1109/22.392907

    Google Scholar 

  8. Paulides MM, Bakker JF, Chavannes N, Van Rhoon GC (2007) A patch antenna design for application in a phased-array head and neck hyperthermia applicator. IEEE Trans Biomed Eng 54:2057–2063

    Article  Google Scholar 

  9. Balanis CA (1997) Antenna theory analysis and design, 2nd ed. John Wiley and Sons Inc., New York, p 774

  10. Yee KS (1966) Numerical solution of initial boundary value problems in isotropic media. IEEE Trans Ant Prop 14:302–307

    Article  MATH  Google Scholar 

  11. Taflove A (1980) Application of the finite-difference time-domain method to sinusoidal steady state electromagnetic penetration problems. IEEE Trans Electromagn Compat 22:191–202

    Article  Google Scholar 

  12. Gabriel S, Lau RW, Gabriel C (1996) The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol 41:2271–2293

    Article  Google Scholar 

  13. Ellison WJ, Lamkaouchi K, Moreau JM (1996) Water: a dielectric reference. J Mol Liquids 68:171–279

    Article  Google Scholar 

  14. Taflove A, Hagness SC (2000) Computational electrodinamics: the finite-difference time-domain method, 2nd ed. Artech House, Boston-London, pp 235–284

  15. Schmid & Partner Engineering AG (2008) SEMCAD-X reference manual, pp 11–13

  16. Knöchel R, Meyer W (1982) Dynamic ’in vivo’ performance of temperature controlled local microwave hyperthermia at 2.45 GHz. Microwave Symp Digest MTT-S Int 82:444–447

    Article  Google Scholar 

  17. Prior CJ, Hall PS (1985) Microstrip disc antenna with short-circuited annular ring. Electron Lett 21:719–721

    Article  Google Scholar 

  18. Lin JC (1974) A cavity-backed slot radiator for biological effects research. J Microwave Power Electromagn Energy 9:63–68

    Google Scholar 

  19. Dudar TE, Jain RK (1984) Differential responses of normal and tumor microcirculation to hyperthermia. Cancer Res 44:605–612

    Google Scholar 

  20. Sherar MD, Gladman AS, Davidson SR, Easty AC, Joy ML (2004) Infrared thermographic SAR measurements of interstitial hyperthermia applicators: errors due to thermal conduction and convection. Int J Hyperthermia 20:539–555

    Article  Google Scholar 

  21. Van der Zee J, Rietveld PJM, Broekmeyer-Reurink MP, Wielheesen DHM, Van Rhoon GC (2002) Hyperthermia in recurrent breast cancer: form experimental oncology to standard practice. Exp Oncol 24:45–50

    Google Scholar 

  22. Arunachalam K, Stauffer PR, Maccarini PF, Jacobsen S, Sterzer F (2008) Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test load. Phys Med Biol 53:3883–3901

    Article  Google Scholar 

  23. Jacobsen S, Stauffer PR (2007) Can we settle with single-band radiometric temperature monitoring during hyperthermia treatment of chestwall recurrence of breast cancer using a dual-mode transceiving applicator? Phys Med Biol 52:911–928

    Article  Google Scholar 

  24. Chernyavskiy O, Vannucci L, Bianchini P, Difato F, Saieh M, Kubnov L (2009) Imaging of mouse experimental melanoma in vivo and ex vivo by combination of confocal and nonlinear microscopy. Microsc Res Tech 72(6):411–23

    Article  Google Scholar 

Download references

Acknowledgments

This study is funded by the Grant Agency of the Academy of Sciences of the Czech Republic IAA500200510, Institutional Research Concepts No.AV0Z50200510, by the Grant Agency of the Czech Republic, Grant No. 102/08/H081 and by the research program MSM6840770012 “Transdisciplinary Research in the Area of Biomedical Engineering II.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Paolo Togni.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Togni, P., Vrba, J. & Vannucci, L. Microwave applicator for hyperthermia treatment on in vivo melanoma model. Med Biol Eng Comput 48, 285–292 (2010). https://doi.org/10.1007/s11517-009-0563-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-009-0563-8

Keywords

Navigation