Abstract
After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9 %. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.







Similar content being viewed by others
References
Bingham J, Li G (2006) An optimized image matching method for determining in vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. J Biomech Eng 128(4):588–595
Canny J (1986) A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698
Fukuoka Y, Hoshino A, Ishida A (1999) A simple radiographic measurement method for polyethylene wear in total knee arthroplasty. IEEE Trans Rehabil Eng 7:228–233
Hirokawa S, Ariyoshi S, Hossain MA (2005) A 3D kinematic measurement of knee prosthesis using X-ray projection images (countermeasure to the overlap between the tibial and femoral silhouettes). JSME Int J Bioeng Ser C 48(4):570–576
Hanson GR, Suggs JF, Freiberg AA, Durbhakula S, Li G (2006) Investigation of in vivo 6DOF total knee arthroplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24(5):974–981
Hirokawa S, Hossain MA, Kihara Y, Ariyoshi S (2008) A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images. Med Biol Eng Comput 46(12):1253–1262
Kärrholm J (1989) Roentgen stereophotogrammetry. Review of orthopaedic applications. Acta Orthop Scand 60(4):491–503
Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JHC (2003) A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 36(6):873–882
Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JHC (2004) Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis. Proc Inst Mech Eng Part H 218(4):231–238
Kärrholm J, Gill RHS, Valstar ER (2007) Radiostereometry (RSA): an accurate tool to assess micromotion of orthopaedic implants. 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, California
Lai JY, Dai WL, Syu CB, Shih KS, Chang RY, Wang WT, Lin SC (2010) A new registration method for three-dimensional knee nearthrosis model using two X-ray images. Comput Methods Biomech Biomed Eng 13(2):265–278
Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2003) A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging 22(12):1561–1574
Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2005) Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images. J Biomech 38(2):229–239
Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9:62–66
Powell MJD (1964) An efficient method for finding the minimum of a function of several variables without calculating derivates. Comput J 7(2):155–162
Scarvell JM, Pickering MR, Smith PN (2010) New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy. J Orthop Res 28(3):334–340
Syu CB, Lai JY, Chang RY, Shih KS, Chen KJ, Lin SC (2012) Automatic model-based Roentgen stereophotogrammetric analysis (RSA) of total knee prostheses. J Biomech 45(1):164–171
Shih KS, Lee CH, Syu CB, Lai JY, Chen KJ, Lin SC (2012) Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA)—design of a rotation platform. Proc Instn Mech Eng Part H 226(10):766–775
Tersi L, Fantozzi S, Stagni R (2010) 3D elbow kinematics with monoplanar fluoroscopy: in silico evaluation. EURASIP J Adv Signal Process 2010:1–10
Tsai TY, Lu TW, Chen CM, Kuo MY, Hsu HC (2010) A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. Med Phys 37(3):1273–1284
Tersi L, Fantozzi S, Stagni R (2014) Characterization of the performance of memetic algorithms for the automation of bone tracking with fluoroscopy. IEEE Trans Evolut Comput (in press)
Vrooman HA, Valstar ER, Brand GJ, Admiraal DR, Rozing PM, Reiber JHC (1998) Fast and accurate automated measurements in digitized stereophotogrammetric radiographs. J Biomech 31(5):491–498
Valstar ER, Vrooman HA, Toksvig-Larsen S, Ryd L, Nelissen RGHH (2000) Digital automated RSA compared to manually operated RSA. J Biomech 33(12):1593–1599
Valstar ER, Jong FWD, Vrooman HA, Rozing PM, Reiber JHC (2001) Model-based roentgen stereophotogrammetry of orthopaedic implants. J Biomech 34:715–722
Valstar ER, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572
Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Yoshikawa H, Tamura S (2004) Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Medical Imaging 23(5):602–612
Acknowledgments
The authors are very grateful to the Shin Kong Wu Ho-Su memorial hospital and Taipei Medical University, Taiwan for the funding support (Project No. SKH-TMU-100-14).
Author information
Authors and Affiliations
Corresponding author
Additional information
Chi-Pin Hsu and Kao-Shang Shih have contributed equally to this work.
Rights and permissions
About this article
Cite this article
Hsu, CP., Lin, SC., Shih, KS. et al. Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA). Med Biol Eng Comput 52, 1061–1071 (2014). https://doi.org/10.1007/s11517-014-1206-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-014-1206-2