Abstract
Framework misfit is a common problem observed in overdentures, which might result in prosthetic and biological complications. The aim of this study was to evaluate the influence of vertical misfit and clip material on the stress distribution in an overdenture-retaining bar system under masticatory loading. A 3-D finite element model of a resorbed jaw was created, including two implants and a bar-clip retained overdenture. A pressure of 100 MPa was applied to the right mandibular first molar. Different vertical misfit levels (50, 100, and 200 µm) and clip materials (plastic or gold) were evaluated. Data were evaluated using von Mises stress and microstrain. Vertical misfit amplification caused an increase in the microstrain values in the peri-implant bone tissue next to the ill-fitted component and increased the stresses in the prosthetic screws. The clip material influenced the stress and microstrain distribution in the prosthetic components and bone tissue. The levels of vertical misfit seem to be closely linked with the stress values in the prosthetic screws, mainly to that of the ill-fitted component. The gold clip presented an increase in the stress compared to the plastic clip.



Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
Abreu RT, Spazzin AO, Noritomi PY, Consani RL, Mesquita MF (2010) Influence of material of overdenture-retaining bar with vertical misfit on three-dimensional stress distribution. J Prosthodont 19(6):425–431
Adell R, Lekholm U, Rockler B, Branemark PI (1981) A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 10(6):387–416
Akca K, Cehreli MC (2006) Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis. Med Biol Eng Comput 44(7):527–535
Akca K, Eser A, Cavusoglu Y, Sagirkaya E, Cehreli MC (2015) Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants. Med Biol Eng Comput 53(5):453–462
Allen EP, Bayne SC, Brodine AH, Cronin RJ Jr, Donovan TE, Kois JC et al (2003) Annual review of selected dental literature: report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 90(1):50–80
Al-Turki LE, Chai J, Lautenschlager EP, Hutten MC (2002) Changes in prosthetic screw stability because of misfit of implant-supported prostheses. Int J Prosthodont 15(1):38–42
Bacchi A, Consani RL, Mesquita MF, dos Santos MB (2012) Influence of different mucosal resiliency and denture reline on stress distribution in peri-implant bone tissue during osseointegration. A three-dimensional finite element analysis. Gerodontology 29(2):e833–e837
Bacchi A, Consani RL, Mesquita MF, Dos Santos MB (2013) Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis. Acta Odontol Scand 71(5):1243–1249
Bacchi A, Consani RL, Mesquita MF, dos Santos MB (2013) Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis. J Oral Sci 55(3):239–244
Carlsson GE, Omar R (2010) The future of complete dentures in oral rehabilitation. A critical review. J Oral Rehabil 37(2):143–156
Cehreli MC, Comert A, Akkocaoglu M, Tekdemir I, Akca K (2006) Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets. Med Biol Eng Comput 44(1–2):86–94
Chang WJ, Lin CL (2010) Estimation of the retainer height biomechanical contribution in posterior resin-bonded fixed partial dentures: a structural-thermal coupled finite element analysis. Med Biol Eng Comput 48(11):1115–1122
Dos Santos MB, Da Silva Neto JP, Consani RL, Mesquita MF (2011) Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps. J Oral Rehabil 38(9):691–696
dos Santos MB, Consani RL, Mesquita MF (2013) Influence of different soft liners on stress distribution in peri-implant bone tissue during healing period. A 3D finite element analysis. J Oral Implantol 39(5):575–581
Dos Santos MB, Bacchi A, Correr-Sobrinho L, Consani RL (2014) The influence of clip material and cross sections of the bar framework associated with vertical misfit on stress distribution in implant-retained overdentures. Int J Prosthodont 27(1):26–32
dos Santos MB, Caldas RA, Zen BM, Bacchi A, Correr-Sobrinho L (2015) Adaptation of overdenture-bars casted in different metals and their influence on the stress distribution—a laboratory and 3D FEA. J Biomech 48(1):8–13
Dos Santos MB, Bacchi A, Consani RL, Correr-Sobrinho L (2015) Influence of diamond like carbon coating of screws on axial tightening force and stress distribution on overdenture bar frameworks with different fit levels and materials. Int J Oral Maxillofac Implants 30(5):1019–1027
Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S et al (2002) The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24–25, 2002. Int J Oral Maxillofac Implants 17(4):601–602
Fromentin O, Lassauzay C, AbiNader S, Feine J, de AlbuquerqueJunior RF (2010) Testing the retention of attachments for implant overdentures—validation of an original force measurement system. J Oral Rehabil 37(1):54–62
Frost HM (2003) Bone’s mechanostat: a 2003 update. Anat Rec A Discov Mol Cell Evol Biol 275(2):1081–1101
Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY (2003) Clinical complications with implants and implant prostheses. J Prosthet Dent 90(2):121–132
Gratton DG, Aquilino SA, Stanford CM (2001) Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent 85(1):47–52
Hellden LB, Derand T (1998) Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants. Int J Oral Maxillofac Implants 13(2):190–196
Inglam S, Suebnukarn S, Tharanon W, Apatananon T, Sitthiseripratip K (2010) Influence of graft quality and marginal bone loss on implants placed in maxillary grafted sinus: a finite element study. Med Biol Eng Comput 48(7):681–689
Kunavisarut C, Lang LA, Stoner BR, Felton DA (2002) Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 11(1):30–40
Spazzin AO, Abreu RT, Noritomi PY, Consani RL, Mesquita MF (2011) Evaluation of stress distribution in overdenture-retaining bar with different levels of vertical misfit. J Prosthodont 20(4):280–285
Spazzin AO, Dos Santos MB, Sobrinho LC, Consani RL, Mesquita MF (2011) Effects of horizontal misfit and bar framework material on the stress distribution of an overdenture-retaining bar system: a 3D finite element analysis. J Prosthodont 20(7):517–522
Spazzin AO, Costa AR, Correr AB, Consani RL, Correr-Sobrinho L, dos Santos MB (2013) Effect of bar cross-section geometry on stress distribution in overdenture-retaining system simulating horizontal misfit and bone loss. J Biomech 46(12):2039–2044
Thomason JM (2010) The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life. J Evid Based Dent Pract 10(1):61–63
Trakas T, Michalakis K, Kang K, Hirayama H (2006) Attachment systems for implant retained overdentures: a literature review. Implant Dent 15(1):24–34
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
dos Santos, M.B.F., Zen, B.M. & Bacchi, A. Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading. Med Biol Eng Comput 54, 1515–1521 (2016). https://doi.org/10.1007/s11517-015-1426-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-015-1426-0