Abstract
Purpose
In recent years, image-guided liver surgery based on intraoperative ultrasound (US) imaging has become common. Using an efficient point-based registration method to improve both accuracy and computational time for the registration of predeformation computer tomography, liver images with postdeformation US images are important during surgical procedure. Although iterative closest point (ICP) algorithm is widely used in surface-based registration, its performance strongly depends on the presence of noise and initial alignment. A registration technique based on unscented Kalman filter (UKF), which has been proposed recently, can used to overcome the noise and outliers on an incremental basis; however, the technique is associated with computational complexity.
Methods
To overcome the limitations of ICP and UKF algorithms, we proposed an incremental two-stage registration method based on the combination of ICP and UKF algorithms to update the registration process with the acquired new points from US images. The registration is based on both the vessels and surface information of the liver.
Results
The two-stage method was examined using numerical simulations and phantom data sets. The results of the phantom data set confirmed that the two-stage method outperforms the accuracy of ICP by 23 % and reduces the running time of UKF by 60 %.
Conclusion
The convergence rate, computational speed, and accuracy of the UKF algorithm can be improved using the two-stage method.










Similar content being viewed by others
References
Lange T, Papenberg N, Heldmann S, Modersitzki J, Fischer B, Lamecker H, Schlag PM (2009) 3D ultrasound-CT registration of the liver using combined landmark-intensity information. Int J Comput Assist Radiol Surg 4(1):79–88
Ferrucci JT (1994) Liver tumor imaging. Current concepts. Radiol Clin North Am 32(1):39–54
Fraunhofer Institute For Medical Image Computing. http://www.mevis.fraunhofer.de/loesungen/navigated-soft-tissue-surgery.html. Accessed 25 December 2012
McLaughlin RA, Hipwell J, Hawkes DJ, Noble JA, Byrne JV, Cox TC (2005) A comparison of a similarity-based and a feature-based 2-D-3-D registration method for neurointerventional use. IEEE Trans Med Imaging 24(8):1058–1066. doi:10.1109/tmi.2005.852067
Besl PJ, McKay HD (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239–256. doi:10.1109/34.121791
Horn B (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(4):629–642. doi:citeulike-article-id:1402193
Umeyama S (1991) Least-squares estimation of transformation parameters between two point patterns. IEEE Trans Pattern Anal Mach Intell 13(4):376–380. doi:10.1109/34.88573
Sandhu R, Dambreville S, Tannenbaum A (2010) Point set registration via particle filtering and stochastic dynamics. IEEE Trans Pattern Anal Mach Intell 32(8):1459–1473. doi:10.1109/tpami.2009.142
Maier-Hein L, Franz AM, dos Santos TR, Schmidt M, Fangerau M, Meinzer H, Fitzpatrick JM (2012) Convergent iterative closest-point algorithm to accomodate anisotropic and inhomogenous localization error. IEEE Trans Pattern Anal Mach Intell 34(8):1520–1532
Moghari MH, Abolmaesumi P (2007) Point-based rigid-body registration using an unscented Kalman filter. IEEE Trans Med Imaging 26(12):1708–1728
Loizou CP, Pattichis CS (2008) Despeckle filtering algorithms and software for ultrasound imaging. Synthesis Lectures on Algorithms and Software in Engineering 1(1):1–166
Czerwinski RN, Jones DL, O’Brien WD Jr (1998) Line and boundary detection in speckle images. IEEE Trans Image Process 7(12):1700–1714. doi:10.1109/83.730381
Lee D, Nam WH, Lee JY, Ra JB (2011) Non-rigid registration between 3D ultrasound and CT images of the liver based on intensity and gradient information. Phys Med Biol 56(1):37–117. doi:10.1088/0031-9155/56/1/008 1361–6560 (Electronic)
Chan TF, Vese LA (2001) Active contours without edges. IEEE Trans Image Process 10(2):266–277
Hassouna MS, Farag AA (2007) MultiStencils fast marching methods: a highly accurate solution to the Eikonal equation on Cartesian domains. IEEE Trans Pattern Anal Mach Intell 29(9):1563–1574. doi:10.1109/tpami.2007.1154
Bentley JL (1975) Multidimensional binary search trees used for associative searching. Commun ACM 18(9):509–517. doi:10.1145/361002.361007
Maier-Hein L, dos Santos TR, Franz AM, Meinzer H-P (2010) Iterative closest point algorithm in the presence of anisotropic noise
Chen SJ-S, Hellier P, Gauvrit J-Y, Marchal M, Morandi X, Collins DL (2010) An anthropomorphic polyvinyl alcohol triple-modality brain phantom based on Colin27. Med Image Comput Assist Interv 13:92–100. doi:10.1007/978-3-642-15745-5_12
Reinertsen I, Lindseth F, Unsgaard G, Collins D (2007) Clinical validation of vessel-based registration for correction of brain-shift. Med Image Anal 11(4):374–388 1361–8415 (Print)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nazem, F., Ahmadian, A., Seraj, N.D. et al. Two-stage point-based registration method between ultrasound and CT imaging of the liver based on ICP and unscented Kalman filter: a phantom study. Int J CARS 9, 39–48 (2014). https://doi.org/10.1007/s11548-013-0907-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11548-013-0907-6