Abstract
Purpose
To present an automated method for detecting endotracheal (ET) tubes and marking their tips in portable chest radiography (CXR) for intensive care units (ICUs).
Methods
In this method, the lung region is first estimated and then the spine is detected between the right lung and the left lung. Because medical tubes are inserted into the body through the throat, the region of interest (ROI) is obtained across the spine. A seed point is determined in the cervical region of the ROI, and then the line path is selected from the seed point. In order to detect ET tubes, the ICU CXR image is preprocessed by contrast-limited adaptive histogram equalization. Then, a feature-based threshold method is applied to the line path to determine the tip location. A comparison to the method by use of Hough transform is also presented. The distance (error) between the detected locations and the locations annotated by a radiologist is used to evaluate the detection precision for the tip location.
Results
The proposed method is evaluated using 44 images with ET tubes and 43 images without ET tubes. The discriminant performance for detecting the existence of ET tubes in this study was 95 %, and the average of detection error for the tip location was approximately 2.5 mm.
Conclusions
The proposed method could be useful for detecting malpositioned ET tubes in ICU CXRs.















Similar content being viewed by others
References
Trotman-Dickenson BM (2003) Radiology in the intensive care unit (part I). J Intens Care Med 18:198–210
Blayney MP, Logan DR (1994) First thoracic vertebral body as reference for endotracheal tube placement. Arch Dis Child-Fetal Neonatal Edn 71:32–35
Behrens B, Rohr K, Stiehl H (2001) Using an extended hough transformation combined with a Kalmann filter to segment tubular structures in 3D medical images. In: Proceedings of workshop vision, modeling, and visualization. Aka GmbH, Heidelberg
Staib LH, Duncan JS (1996) Model-based deformable surface finding for medical images. IEEE Trans Med Imaging 15:720–731
McInerney T, Terzopoulos D (1996) Deformable models in medical image analysis: a survey. Med Image Anal 1:91–108
Mitsuhashi R, Aoki Y, Kouno M, Hatsuda T (1993) Detection of a straight metal tube by snow search radar. In: Proceedings of geoscience and remote sensing symposium, 1993 (IGARSS’93). Better understanding of earth environment. IEEE, New York
Kender JR, Kjeldsen R (1995) On seeing spaghetti: self-adjusting piecewise toroidal recognition of flexible extruded objects. IEEE Trans Pattern Anal Mach Intell 17:136–157
Black JJM, Skinner DV (2000) Confirmation of correct endotracheal tube placement. J Accid Emerg Med 17:74–74
Sheng C, Li L, Pei W (2009) Automatic detection of supporting device positioning in intensive care unit radiography. Int J Med Robot Comp 5:332–340
Ramakrishna B, Brown M, Goldin J, Cagnon C, Enzmann D (2011) Catheter detection and classification on chest radiographs: an automated prototype computer-aided detection (CAD) system for radiologists. In: Medical Imaging 2011: Computer-aided diagnosis, p 7963
Ramakrishna B, Brown M, Goldin J, Cagnon C, Enzmann D (2012) An improved automatic computer aided tube detection and labeling system on chest radiographs. In: Medical imaging 2012: computer-aided diagnosis, p 8315
Mercan CA, Celebi MS (2014) An approach for chest tube detection in chest radiographs. IET Image Process 8:122–129
Kao EF, Jaw TS, Li CW, Chou MC, Liu GC (2015) Automated detection of endotracheal tubes in paediatric chest radiographs. Comput Methods Prog Biomed 118:1–10
Zuiderveld K (1994) Contrast limited adaptive histogram equalization. In: Proceedings of Graphics gems IV. Academic Press, San Diego, CA
Saleh MD, Eswaran C, Mueen A (2011) An automated blood vessel segmentation algorithm using histogram equalization and automatic threshold selection. J Digit Imaging 24:564–572
Tomasi C, Manduchi R (1998) Bilateral filtering for gray and color images. In: Sixth international conference on computer vision, pp 839–846
Durand F, Dorsey J (2002) Fast bilateral filtering for the display of high-dynamic-range images. ACM Trans Graphics 21:257–266
Chaudhury KN, Sage D, Unser M (2011) Fast bilateral filtering using trigonometric range kernels. IEEE Trans Image Process 20:3376–3382
Al-Haj A, Amer A (2014) Secured telemedicine using region-based watermarking with tamper localization. J Digit Imaging 27:737–750
Sofka M, Wetzl J, Birkbeck N, Zhang J, Kohlberger T, Kaftan J, Declerck J, Zhou SK (2011) Multi-stage learning for robust lung segmentation in challenging CT volumes. Lect Notes Comput Sci 6893:667–674
Funding
This work was supported by the National Science Foundation of China (NSFC) 81101116, the Foundation of Hujiang (C14002), and the National Sciences Foundation of Shanghai (13ZR1410400).
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical standard
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Chen, S., Zhang, M., Yao, L. et al. Endotracheal tubes positioning detection in adult portable chest radiography for intensive care unit. Int J CARS 11, 2049–2057 (2016). https://doi.org/10.1007/s11548-016-1430-3
Received:
Accepted:
Published:
Issue Date: