Skip to main content
Log in

Architecture and Design of a Wearable Robotic System for Body Posture Monitoring, Correction, and Rehabilitation Assist

  • Published:
International Journal of Social Robotics Aims and scope Submit manuscript

Abstract

With the heavy use of consumer electronic devices (CEDs) like smartphones, laptops, etc. in daily life, more and more people feel head, neck, and back pains because of long time poor body postures during the use of these devices. This paper presents a “patients–robots–doctors” architecture and designs a wearable robotic system for body postures monitoring, correction, and rehabilitation assist. The system mainly includes a wearable robotic device (WRD) and the CEDs. The WRD monitors the postures of body segments and reminds the user to correct bad postures. The posture data are sent to CEDs for processing and visualization. The data can also be uploaded to a cloud server for professional analysis by “doctors”. The human body posture is modeled and simulated to show that the different postures of the body segments have large effects on the torques and forces acting on the joints and muscles. A posture detection method is proposed and the WRD is designed. The basic functions of the architecture and system are verified by experiments including head–neck posture, back posture, sleeping posture, and leg posture monitoring and correction warning. The architecture and system can be utilized not only by the patients–doctors in telerehabilitation exercise assist but also by the parents–children in good sitting habits development, the athletes–coaches and bodybuilders–instructors in training efficiency improvement, etc.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17

Similar content being viewed by others

References

  1. Straker L, O’Sullivan P, Kendall G, Sloan N, Pollock C et al (2006) IT kids: exposure to computers and adolescents’ neck posture and pain. Praxis Und Klinik Der Pneumologie 32(5):361–365

    Google Scholar 

  2. Lee M, Hong Y, Lee S, Won J, Yang J et al (2015) The effects of smartphone use on upper extremity muscle activity and pain threshold. J Phys Ther Sci 27(6):1743–1745

    Article  Google Scholar 

  3. Seong-Yeol K, Sung-Ja K (2016) Effect of duration of smartphone use on muscle fatigue and pain caused by forward head posture head posture in adults. J Phys Ther Sci 28(6):1669–1672

    Article  Google Scholar 

  4. Yang C, Wang J (2017) An unusual case of rapidly progressed cervical compression myelopathy caused by overnight inappropriate usage of smartphone device. J Clin Neurosci 39:82–84

    Article  Google Scholar 

  5. Park JH, Kang SY, Lee SG, Jeon HS (2017) The effects of smart phone gaming duration on muscle activation and spinal posture: pilot study. Physiother Theory Pract 33(8):661–669

    Article  Google Scholar 

  6. Straker LM, Smith AJ, Bear N, O’Sullivan PB, de Klerk NH (2011) Neck/shoulder pain, habitual spinal posture and computer use in adolescents: the importance of gender. Ergonomics 54(6):539–546

    Article  Google Scholar 

  7. Zhang Z, Yang G (2015) Monitoring cardio-respiratory and posture movements during sleep: what can be achieved by a single motion sensor. In: IEEE international conference on wearable and implantable body sensor networks, Cambridge, MA, USA, 9–12 June 2015, pp 1–6

  8. Ankrum DR, Nemeth KJ (2000) Head and neck posture at computer workstations—what’s neutral? In: Proceedings of triennial congress international ergonomics association annual meeting on human factors ergonomics association, San Diego, CA, USA, 29 July–4 August 2000, pp 565–568

  9. Guan X, Fan G, Wu X, Zeng Y, Su H et al (2015) Photographic measurement of head and cervical posture when viewing mobile phone: a pilot study. Eur Spine J 24(12):2892–2898

    Article  Google Scholar 

  10. Breen PP, Nisar A, OLaighin G (2009) Evaluation of a single accelerometer based biofeedback system for real-time correction of neck posture in computer users. In: Proceedings of annual international conference on IEEE engineering in medicine and biology society: engineering future biomed, Minneapolis, Minnesota, USA, 2–6 September 2009, pp 7269–7272

  11. Liao D (2016) Design of a secure, biofeedback, head-and-neck posture correction system. In: Proceedings of IEEE international conference on connected health: applications, systems and engineering technologies (CHASE), Washington, DC, USA, 27–29 June 2016, pp 119–125

  12. Dogǎrescu OMS, Pașca SSG (2011) Abnormal posture detection device with audible feedback. In: International symposium on advanced topics in electrical engineering, Bucharest, Romania, 12–14 May 2011, pp 1–4

  13. Lee H, Lee S, Choi YS, Seo Y, Shim E (2013) A new posture monitoring system for preventing physical illness of smartphone users. In: IEEE Consumer Communications and Networking Conference, Las Vegas, NV, USA, 11–14 January 2013, pp 657–661

  14. Yeom H, Lim J, Yoo SH, Lee W (2014) A new posture-correcting system using a vector angle model for preventing forward head posture. Biotechnol Biotechnol Equip 28(S1):S6–S13

    Article  Google Scholar 

  15. Solanki KM (2013) Microcontroller based sign language glove. Int J Sci Res Dev 1(4):831–833

    Google Scholar 

  16. Claeys K, Brumagne S, Deklerck J, Vanderhaeghen J, Dankaerts W (2016) Sagittal evaluation of usual standing and sitting spinal posture. J. Bodyw. Mov. Ther 20(2):326–333

    Article  Google Scholar 

  17. Li MH, Yadollahi A, Taati B (2017) Noncontact vision-based cardiopulmonary monitoring in different sleeping positions. IEEE J Biomed Health Inform 21(5):1367–1375

    Article  Google Scholar 

  18. Bergamasco M, Allotta B, Bosio L, Ferretti L, Parrini G et al (1994) An arm exoskeleton system for teleoperation and virtual environments applications. In: Proceedings of IEEE international conference on robotics and automation, 8–13 May 1994, vol 2, pp 1449–1454

  19. Zoss AB, Kazerooni H, Chu A (2006) Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX). IEEE/ASME Trans Mechatron 11(2):128–138

    Article  Google Scholar 

  20. Salvietti G, Hussain I, Cioncoloni D, Taddei S, Rossi S et al (2017) Compensating hand function in chronic stroke patients through the robotic sixth finger. IEEE Trans Neural Syst Rehabil Eng 25(2):142–150

    Article  Google Scholar 

  21. Jin S, Iwamoto N, Hashimoto K, Yamamoto M (2017) Experimental evaluation of energy efficiency for a soft wearable robotic suit. IEEE Trans Neural Syst Rehabil Eng 25(8):1192–1201

    Article  Google Scholar 

  22. Ong CF, Hicks JL, Delp SL (2016) Simulation-based design for wearable robotic systems: an optimization framework for enhancing a standing long jump. IEEE Trans Biomed Eng 63(5):894–903

    Article  Google Scholar 

  23. Watanabe T, Yano K (2010) Extension assist control for individuals with cervical cord injury using motion assist robot for upper limb. In: Annual international conference on IEEE engineering in medicine and biology society, Buenos Aires, Argentina, August 31–September 4 2010, pp 1312–1315

  24. Yap HK, Kamaldin N, Lim JH, Nasrallah F, Goh JC et al (2017) A magnetic resonance compatible soft wearable robotic glove for hand rehabilitation and brain imaging. IEEE Trans Neural Syst Rehabil Eng 25(6):782–793

    Article  Google Scholar 

  25. Ren Y, Wu Y, Yang C, Xu T, Harvey R, Zhang L (2017) Developing a wearable ankle rehabilitation robotic device for in-bed acute stroke rehabilitation. IEEE Trans Neural Syst Rehabil Eng 25(6):589–596

    Article  Google Scholar 

  26. Vitiello N, Lenzi T, Roccella S, Rossi SMMD, Cattin E et al (2013) NEUROExos: a powered elbow exoskeleton for physical rehabilitation. IEEE Trans Rob 29(1):220–235

    Article  Google Scholar 

  27. Florez JM, Shah M, Moraud EM, Wurth S, Baud L (2017) Rehabilitative soft exoskeleton for rodents. IEEE Trans Neural Syst Rehabil Eng 25(2):107–118

    Article  Google Scholar 

  28. Seshadri DR, Drummond C, Craker J, Rowbottom JR, Voos JE (2017) Wearable devices for sports: new integrated technologies allow coaches, physicians, and trainers to better understand the physical demands of athletes in real time. IEEE Pulse 8(1):38–43

    Article  Google Scholar 

  29. Morningstar MW (2003) Cervical hyperlordosis, forward head posture, and lumbar kyphosis correction: a novel treatment for mid-thoracic pain. J Chiropr Med 2(3):111–115

    Article  Google Scholar 

  30. Harrison DD, Jackson BL, Troyanovich SJ, Robertson G, de George D et al (1994) The efficacy of cervical extension-compression traction combined with diversified manipulation and drop table adjustments in the rehabilitation of cervical lordosis: a pilot study. J Manipulative Physiol Ther 17(7):454–464

    Google Scholar 

  31. Song Z, Guo S (2012) Study on impedance generation using an exoskeleton device for upper-limb rehabilitation. In: IEEE international conference on multisensor fusion and integration for intelligent systems, Hamburg, Germany, 13–15 September 2012, pp 281–286

  32. Yap H, Mao A, Goh JCH, Yeow C (2016) Design of a wearable FMG sensing system for user intent detection during hand rehabilitation with a soft robotic glove. In: Proceedings of IEEE RAS EMBS international conference on biomedical robotics and biomechatronics, UTown, Singapore, 26–29 June 2016, pp 781–786

  33. Lee CK, Jeon HR, Yoon DH, Kim KN, Yi S et al (2016) Clinical outcomes of correcting cervical deformity in cerebral palsy patients. World Neurosurg 96:500–509

    Article  Google Scholar 

  34. Hansraj KK (2014) Assessment of stresses in the cervical spine caused by posture and position of the head. Surg Technol Int 25:277–279

    Google Scholar 

  35. Zhang Z, Ji L, Huang Z, Wu J (2012) Adaptive information fusion for human upper limb movement estimation. IEEE Trans Syst Man Cybern Part A Syst Hum 42(5):1100–1108

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported in part by the Natural Science Foundation of China under Grant 61873066, Natural Science Foundation of Jiangsu Province under Grant BK20181270, and the Fundamental Research Funds for the Central Universities 2242018k10018.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jun Zhang.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhang, J., Zhang, H., Dong, C. et al. Architecture and Design of a Wearable Robotic System for Body Posture Monitoring, Correction, and Rehabilitation Assist. Int J of Soc Robotics 11, 423–436 (2019). https://doi.org/10.1007/s12369-019-00512-3

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12369-019-00512-3

Keywords

Navigation