Abstract
This paper presents equations, which can be used to evaluate the failure frequency and the failure rate of a two identical component parallel redundant system in which each component can operate in its wear out period, and the failure rate of each component is exponential power distribution. The optimum maintenance interval for a two identical component parallel redundant system can be obtained using these equations. The proposed approach is presented and illustrated using several numerical examples. The optimum maintenance interval for each component in a two identical parallel redundant system will depend on factors such as: failure rate, repair and maintenance times of each component in the parallel redundant systems.
Similar content being viewed by others
References
Billinton R, Allan RN (1983) Reliability evaluation of engineering systems. Plenum Press, New York
Billinton R, Allan RN (1984) Reliability evaluation of power systems. Plenum Press, New York
Billinton R, Jun Pan (1998) Optimal maintenance scheduling in a two identical component parallel redundant system. Reliab Eng Syst Safety 59:309–316
Coffman EG, Gilbert EN (1990) Optimal strategies for scheduling checkpoints and preventive maintenance. IEEE Trans Reliab 39(1):9–18
Kuo W, Zuo MJ (2003) Optimal reliability modeling: principles and applications. Wiley, New Jersey
Lawrence M (1986) Life timed distribution identities. IEEE Trans Reliab 35(2):170–174
Michael A, Guth S (1989) Practical considerations in developing an instrument-maintenance plan. IEEE Trans Reliab 38(2):253–264
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
El-Damcese, M.A., Helmy, A.N. Maintenance scheduling for a parallel system subject to exponential power hazard. Int J Syst Assur Eng Manag 3, 64–69 (2012). https://doi.org/10.1007/s13198-012-0095-8
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13198-012-0095-8