Abstract
In deregulated power system, congestion management is a major problem due to operational constraints. Flexible AC transmission systems (FACTS) devices can be a choice to control the power flow in congested lines. This paper explores the use of two popular FACTS devices, TCSC and STATCOM for power flow control in electrical network and their capability to decongest the network. It suggests the optimal location of TCSC and STATCOM individually to relieve congestion with minimum power losses, voltage regulation and cost of the device. The proposed method has been verified on IEEE-14 bus system for its effectiveness. Simulation work is carried out in MATLAB software.
Similar content being viewed by others
References
Brosda J, Handschin E (2001) Congestion management methods with special consideration of FACTS devices. Proceedings of IEEE Power Technology Conference, vol. 1, Porto, Portugal, 2001
Canizares (2000) Power flow and transient stability models of FACTS controllers for voltage and angle stability studies. IEEE Power Eng Soc Winter Meet 2:1447–1454
Gad M, Shinde P, Kulkarni SU (2012) Optimal location of TCSC by sensitivity methods. Int J Comput Eng Res 2(6):162–168
Hingorani NG, Gyugyi L (2012) Understanding FACTS. IEEE Press, New York
Huang GM, Yan P (2002) TCSC and SVC as re-dispatch tools for congestion management and TTC improvement. Proceedings of IEEE PES, Winter Meeting, vol. 1, pp. 660–665, 2002
Hussain SMS, Subbaramiah M (2013) An analytical approach for optimal location of DSTATCOM in radial distribution system. International Conference on Energy Efficient Technologies for Sustainability (ICEETS), Nagercoil, pp.1365–1369, 2013
Khan MT, Siddiqui AS (2014) Congestion management in deregulated power system using FACTS device. Int J Syst Assur Eng Manag. doi:10.1007/s13198-014-0258-x
Masood T, Aggarwal RK, Qureshi SA, Khan RA (2010) STATCOM model against SVC control model performance analyses technique by MATLAB. International Conference on Renewable Energies and Power Quality (ICREPQ’10), Spain, 2010
Musunuri S, Dehnavi G (2010) Comparison of STATCOM, SVC, TCSC, and SSSC performance in steady state voltage stability improvement. North American Power symposium (NAPS), Arlington: 1–7, 2010
Mwanza K, Shi Y, Tuan LA (2007) Economic evaluation of FACTS for congestion management in pool markets. IEEE Power Tech Lausanne, Lausanne, pp 2053–2058
Rajalakshmi L, Suganyadevi MV, Parameswari S (2011) Congestion management in deregulated power system by locating series FACTS devices. Int J Comput Appl 13:19–22
Satyanarayana K, Prasad BKV, Devanand G, Siva Prasad N (2011) Optimal location of TCSC with minimum installation cost using PSO, Vol. 2. Int J Comput Sci Technol 1:156–160
Taher SA, Besharat H (2008) Transmission congestion management by determinig optimal location of FACTS devices in deregulated power systems. Am J Appl Sci 5(3):242–247
Yousefi A, Nguyen TT, Zareipour H, Malik OP (2012) Congestion management using demand response and FACTS devices. Electr Power Eng Syst 37:78–85
Zhang XP, Chong B, Godfrey KR, Yao L, Bazargan M, Schmitt L (2007) Management of congestion costs utilizing FACTS controllers in a bilateral electricity market environment. IEEE Power Tech, Lausanne, pp 1244–1249
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Siddiqui, A.S., Khan, M.T. & Iqbal, F. Determination of optimal location of TCSC and STATCOM for congestion management in deregulated power system. Int J Syst Assur Eng Manag 8 (Suppl 1), 110–117 (2017). https://doi.org/10.1007/s13198-014-0332-4
Received:
Revised:
Published:
Issue Date: