Abstract
A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectronic equipment and results were also compared to the ones obtained by means of a Fast Video Camera. Comparative results showed for the IMU better performance than the system based on the Fast Video Camera. During the rising the mean pitch error was always lower than 5.2 × 10−1 ° and the mean Euclidean error lower than 5.9 × 10−3 m in the sagittal plane.
Similar content being viewed by others
References
Allen FR, Ambikairajah E, Lovell NH, Celler BG (2006) Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models. Phys Meas 27(10):935–952
Andrews JG, Youm Y (1979) A biomechanical investigation of wrist kinematics. J Biomech 12:83–89
Bloem BR, Roon KI, Delleman NJ, Van Dijk JG, Roos RA (1997) Prolonged duration of standing up is an early dopa-sensitive abnormality in Parkinson’s disease. J Neurol Sci 146(1):41–45
Boonstra MC, Van der Slikke RM, Keijsers NL et al (2006) The accuracy of measuring th e kinematics of rising from a chair with accelerometers and gyroscopes. J Biomech 39:354–358
Bradshaw E (2004) Target-directed running in gymnastics: a preliminary exploration of vaulting. Sports Biomech 3(1):125–144
Cappozzo A (1982) Head and trunk mechanics in level walking. PhD Thesis, University of Strathclyde, Glasgow
Cappozzo A, Cappello A, Della Croce U, Pensalfini F (1997) Surface-marker cluster design criteria for 3-D bone movement reconstruction. IEEE Trans Biomed Eng 44:1165–1174
Chiari L, Dozza M, Horak F, Cappello A, Macellari V, Giansanti D (2005) Audio-biofeedback for balance improvement: an accelerometry based system. IEEE Trans Biomed Eng 52(12):2108–2111
Costantini G, Carota M, Maccioni G, Giansanti D (2006) Classification of the sit-to-stand locomotion task based on spectral analysis of waveforms generated by accelerometric transducer. Electron Lett 42(3):142–148
D’Agostino R, Stephens M (1986) Goodness-of-fit techniques. Marcel Dekker, Inc, New York
DMC-1400 Series Manual By Galil Motion Control Inc. (MANUAL) (2000)
Elliott B, Plunkett D, Alderson J (2005) The effect of altered pitch length on performance and technique in junior fast bowlers. J Sports Sci 23(7):661–667
Elliott B, Wallis R, Sakurai S, Lloyd D, Besier T (2002) The measurement of shoulder alignment in cricket fast bowling. J Sports Sci 20(6):507–510
Feland JB, Hager R, Merrill RM (2005) Sit to stand transfer: performance in rising power, transfer time and sway by age and sex in senior athletes. Br J Sports Med 39(11):379–386
Giansanti D (2006) Does centripetal acceleration affect trunk flexion monitoring by means of accelerometers?. Physiol Meas 27:999–1008
Giansanti D, Maccioni G (2005) Comparison of three different kinematic sensors assemblies for the locomotion study. Physiol Meas 26:689–705
Giansanti D, Maccioni G (2006) Physiological motion monitoring: wearable device and adaptive algorithm for sit-to-stand timing detection. Physiol Meas 27:713–723
Giansanti D, Maccioni G, Macellari V (2005) The development and test of a device for the reconstruction of 3D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers. IEEE Trans Biomed Eng 52(7):1271–1277
Giansanti D, Maccioni G, Macellari V (2006) Detecting the sit-to-stand phases by means of a wearable device. Gait Posture 24(suppl 1):SS55–SS56
Giansanti D, Macellari V, Maccioni G, Cappozzo A (2003) Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?. IEEE Trans Biomed Eng 50(4):476–483
Hatze H (1981) The use of optimally regularized Fourier series for estimating higher-order derivatives of noisy biomechanical data. J Biomech 14:13–18
Janssen WG, Bussmann JB, Horemans HL, Stam HJ (2005) Analysis and decomposition of accelerometric signals of trunk and thigh obtained during the sit-to-stand movement. Med Biol Eng Comput 43(2):265–272
Kerr KM (1997) Analysis of the sit to stand movement cycle in normal subjects. Clin Biomech 12:236–245
Kralj A (1990) Analysis of standing up and sitting down in humans: definitions and normative data presentation. J Biomech 23:1123–1138
Manckoundia P, Mourey F, Fitzenmeyer P, Papaxanthis C (2005) Comparison of motor strategies in STS and back-to-sit motions between healthy and Alzheimer’s disease elderly subjects. J Neurosci [Epub ahead of print]
Mathie MJ, Celler BG, Lovell NH, Coster AC (2004a) Classification of basic daily movements using a triaxial accelerometer. Med Biol Eng Comput 42(5):679–87
Mathie MJ, Coster AC, Lovell NH, Celler BG (2003) Detection of daily physical activities using a triaxial accelerometer. Med Biol Eng Comput 41(3):296–301
Mathie JM, Coster ACF, Lovell NH, Celler BG (2004b) Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement. Physiol Meas 25:R1–R20
Mathie MJ, Coster AC, Lovell NH, Celler BG, Lord SR, Tiedemann A (2004c) A pilot study of long-term monitoring of human movements in the home using accelerometry. J Telemed Telecare 10(3):144–151
Nilsson J, Tveit P, Eikrehagen O (2004) Effects of speed on temporal patterns in classical style and freestyle cross-country skiing. Sports Biomech 3(1):85–107
Raab FH, Blood EB, Steiner TO, Jones HR (1979) Magnetic position and orientation tracking system. IEEE Trans Aerospace Electr Syst 15:709–718
Sherrington C, Lord SR (2005) Reliability of simple portable tests of physical performance in older people after hip fracture. Clin Rehabil 19(5):496–504
Tinetti ME, Baker DI, McAvay G et al (1994) A multifactorial intervention to reduce the risk of falling among elderly people living in the community. NEJM 331:821–827
Tinetti ME, Inouye SK, Gill TM, Doucette JT (1995) Shared risk factors for falls, incontinence and functional independence: unifying the approach to geriatric syndromes. JAMA 273(17):1348–1353
Veltink PH, Luinge HJ, Kooi BJ, Baten CTM, Slycke P, Olthuis W, Bergveld P (2001) The artificial vestibular system—design of a tri-axial inertial sensor system and its application in the study of human movement. In: Duysens J, Smits-Engelsman B, Kingma H (eds) Control of posture and gait. Proceedings of ISPG conference, Maastricht, pp 894–899
Whitney SL, Wrisley DM, Marchetti GF, Gee MA, Redfern MS, Furman JM (2005) Clinical measurement of STS performance in people with balance disorders: validity of data for the five-times-STS Test. Phys Ther 85(10):1034–1045
Williamson R, Andrews BJ (2001) Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes. Med Biol Eng Comput 39(3):294–302
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Giansanti, D., Maccioni, G., Benvenuti, F. et al. Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects. Med Bio Eng Comput 45, 969–976 (2007). https://doi.org/10.1007/s11517-007-0224-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-007-0224-8