Abstract
Hip protectors are often prescribed to the elderly who are at risk of falling, with the goal of preventing hip fractures. However, determining the effectiveness of hip protectors has been hampered by unreliable compliance data. This study reports a reliable objective method of measuring compliance and the developed method could be used in any climate, regardless of temperature. Custom compliance monitors were built and embedded inside hip protectors. An algorithm was developed to utilize both temperature and acceleration to determine compliance. Seven young volunteers (age 24.6 ± 4.2 years old) wore the protectors for a total of 667 h while closely recording their compliance. One female (77 years old) who had hip fracture history wore the compliance monitors for 91.6 % of the time during a 1-week stay in a hospital. From the volunteers’ trial, using temperature alone overpredicted compliance by 1.2 % and using acceleration alone overpredicted by 5.4 %, but using a combination of the two methods plus a correction factor only underestimated by 0.6 %. From the elderly data, the average compliance recorded from the temperature, acceleration, and combined methods with correction was 94.6, 88.9, and 90.2, respectively. The high accuracy of temperature sensors in this study will not be attainable in hot climates where most of the worldwide increase in hip fractures is occurring. The developed monitor with the algorithm provided high accuracy in determining compliance and was able to determine both the longitudinal and cross-sectional compliance at any time.
Similar content being viewed by others
References
Cameron ID, Fisher W, Lockwood K et al (2011) Assessing adherence to use of Hip Protectors: automated monitoring is feasible. J Am Geriatr Soc 59(9):1766–1767
Cryer C, Knox A, Martin D et al (2002) Hip protector compliance among older people living in residential care homes. Inj Prev 8:202–206
Cummings SR, Melton LJ (2002) Epidemiology and outcomes of osteoporotic fractures. Lancet 359(9319):1761–1767
Gillespie WJ, Gillespie LD, Parker MJ (2010) Hip protectors for preventing hip fractures in older people. In: Parker MJ (eds) Cochrane database of systematic reviews, the Cochrane collaboration, Wiley, Chichester
Gulberg B, Johnell O, Kanis JA (1997) World-wide projections for hip fracture. Osteoporos Int 7(5):407–413
Kannus P, Parkkari J (2006) Prevention of hip fracture with hip protectors. Age Ageing 35:S2ii51–54
Kurrle SE, Cameron ID, Quine S et al (2004) Adherence with hip protectors: a proposal for standardised definitions. Osteoporos Int 15(1):1–4
Ling X, Aimin L, Xihe Z et al (1996) Very low rates of hip fracture in Beijing, People’s Republic of China: the Beijing osteoporosis project. Am J Epidemiol 144(9):901–907
Miller DJ, Franzone JM, Matsumoto H et al (2012) Electronic monitoring improves brace-wearing compliance in patients with adolescent idiopathic scoliosis. Spine 37(9):717–721
Nicholson GP, Ferguson-Pell MW, Smith K et al (2003) The objective measurement of spinal orthosis use for the treatment of adolescent idiopathic scoliosis. Spine 28(19):2243
Parker MJ (2006) Effectiveness of hip protectors for preventing hip fractures in elderly people: systematic review. BMJ 332(7541):571–574
Parkkari J, Heikkilä J, Kannus P (1998) Acceptability and compliance with energy-shunting hip protectors: a 6-month prospective follow-up in a Finnish nursing home. Age Ageing 27:225–229
Sawka AM, Ismaila N, Raina P et al (2010) Hip fracture prevention strategies in long-term care- A survey of Canadian physicians’ opinions. Can Fam Physician 56:392–397
Tracey M, Villar A, Hill P et al (1998) Will elderly rest home residents wear hip protectors? Age Ageing 27:195–198
Van Den Kroonenberg AJ, Hayes WC, McMahon TA (1995) Dynamic models for sideways falls from standing height. J Biomech Eng 117(3):309–318
Van Schoor NM, Deville WL, Bouter LM et al (2002) Acceptance and compliance with external hip protectors: a systematic review of the literature. Osteoporos Int 13(12):917–924
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Evans, K.R., Lou, E., Woloschuk, C. et al. Quantitative measurement of hip protector use and compliance. Med Biol Eng Comput 52, 9–15 (2014). https://doi.org/10.1007/s11517-013-1116-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-013-1116-8