Skip to main content

Advertisement

Log in

Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA)

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9 %. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Bingham J, Li G (2006) An optimized image matching method for determining in vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. J Biomech Eng 128(4):588–595

    Article  PubMed  Google Scholar 

  2. Canny J (1986) A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698

    Article  CAS  PubMed  Google Scholar 

  3. Fukuoka Y, Hoshino A, Ishida A (1999) A simple radiographic measurement method for polyethylene wear in total knee arthroplasty. IEEE Trans Rehabil Eng 7:228–233

    Article  CAS  PubMed  Google Scholar 

  4. Hirokawa S, Ariyoshi S, Hossain MA (2005) A 3D kinematic measurement of knee prosthesis using X-ray projection images (countermeasure to the overlap between the tibial and femoral silhouettes). JSME Int J Bioeng Ser C 48(4):570–576

    Article  Google Scholar 

  5. Hanson GR, Suggs JF, Freiberg AA, Durbhakula S, Li G (2006) Investigation of in vivo 6DOF total knee arthroplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24(5):974–981

    Article  PubMed  Google Scholar 

  6. Hirokawa S, Hossain MA, Kihara Y, Ariyoshi S (2008) A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images. Med Biol Eng Comput 46(12):1253–1262

    Article  PubMed  Google Scholar 

  7. Kärrholm J (1989) Roentgen stereophotogrammetry. Review of orthopaedic applications. Acta Orthop Scand 60(4):491–503

    Article  PubMed  Google Scholar 

  8. Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JHC (2003) A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 36(6):873–882

    Article  CAS  PubMed  Google Scholar 

  9. Kaptein BL, Valstar ER, Stoel BC, Rozing PM, Reiber JHC (2004) Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis. Proc Inst Mech Eng Part H 218(4):231–238

    Article  CAS  Google Scholar 

  10. Kärrholm J, Gill RHS, Valstar ER (2007) Radiostereometry (RSA): an accurate tool to assess micromotion of orthopaedic implants. 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, California

  11. Lai JY, Dai WL, Syu CB, Shih KS, Chang RY, Wang WT, Lin SC (2010) A new registration method for three-dimensional knee nearthrosis model using two X-ray images. Comput Methods Biomech Biomed Eng 13(2):265–278

    Article  Google Scholar 

  12. Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2003) A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging 22(12):1561–1574

    Article  PubMed  Google Scholar 

  13. Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2005) Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images. J Biomech 38(2):229–239

    Article  PubMed  Google Scholar 

  14. Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9:62–66

    Article  Google Scholar 

  15. Powell MJD (1964) An efficient method for finding the minimum of a function of several variables without calculating derivates. Comput J 7(2):155–162

    Article  Google Scholar 

  16. Scarvell JM, Pickering MR, Smith PN (2010) New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy. J Orthop Res 28(3):334–340

    PubMed  Google Scholar 

  17. Syu CB, Lai JY, Chang RY, Shih KS, Chen KJ, Lin SC (2012) Automatic model-based Roentgen stereophotogrammetric analysis (RSA) of total knee prostheses. J Biomech 45(1):164–171

    Article  PubMed  Google Scholar 

  18. Shih KS, Lee CH, Syu CB, Lai JY, Chen KJ, Lin SC (2012) Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA)—design of a rotation platform. Proc Instn Mech Eng Part H 226(10):766–775

    Article  Google Scholar 

  19. Tersi L, Fantozzi S, Stagni R (2010) 3D elbow kinematics with monoplanar fluoroscopy: in silico evaluation. EURASIP J Adv Signal Process 2010:1–10

  20. Tsai TY, Lu TW, Chen CM, Kuo MY, Hsu HC (2010) A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. Med Phys 37(3):1273–1284

    Article  PubMed  Google Scholar 

  21. Tersi L, Fantozzi S, Stagni R (2014) Characterization of the performance of memetic algorithms for the automation of bone tracking with fluoroscopy. IEEE Trans Evolut Comput (in press)

  22. Vrooman HA, Valstar ER, Brand GJ, Admiraal DR, Rozing PM, Reiber JHC (1998) Fast and accurate automated measurements in digitized stereophotogrammetric radiographs. J Biomech 31(5):491–498

    Article  CAS  PubMed  Google Scholar 

  23. Valstar ER, Vrooman HA, Toksvig-Larsen S, Ryd L, Nelissen RGHH (2000) Digital automated RSA compared to manually operated RSA. J Biomech 33(12):1593–1599

    Article  CAS  PubMed  Google Scholar 

  24. Valstar ER, Jong FWD, Vrooman HA, Rozing PM, Reiber JHC (2001) Model-based roentgen stereophotogrammetry of orthopaedic implants. J Biomech 34:715–722

    Article  CAS  PubMed  Google Scholar 

  25. Valstar ER, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572

    Article  PubMed  Google Scholar 

  26. Yamazaki T, Watanabe T, Nakajima Y, Sugamoto K, Tomita T, Yoshikawa H, Tamura S (2004) Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Medical Imaging 23(5):602–612

    Article  Google Scholar 

Download references

Acknowledgments

The authors are very grateful to the Shin Kong Wu Ho-Su memorial hospital and Taipei Medical University, Taiwan for the funding support (Project No. SKH-TMU-100-14).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chian-Her Lee.

Additional information

Chi-Pin Hsu and Kao-Shang Shih have contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hsu, CP., Lin, SC., Shih, KS. et al. Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA). Med Biol Eng Comput 52, 1061–1071 (2014). https://doi.org/10.1007/s11517-014-1206-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-014-1206-2

Keywords

Navigation