Pseudo-real-time low-pass filter in ECG, self-adjustable to the frequency spectra of the waves

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

The electrocardiogram (ECG) acquisition is often accompanied by high-frequency electromyographic (EMG) noise. The noise is difficult to be filtered, due to considerable overlapping of its frequency spectrum to the frequency spectrum of the ECG. Today, filters must conform to the new guidelines (2007) for low-pass filtering in ECG with cutoffs of 150 Hz for adolescents and adults, and to 250 Hz for children. We are suggesting a pseudo-real-time low-pass filter, self-adjustable to the frequency spectra of the ECG waves. The filter is based on the approximation procedure of Savitzky–Golay with dynamic change in the cutoff frequency. The filter is implemented pseudo-real-time (real-time with a certain delay). An additional option is the automatic on/off triggering, depending on the presence/absence of EMG noise. The analysis of the proposed filter shows that the low-frequency components of the ECG (low-power P- and T-waves, PQ-, ST- and TP-segments) are filtered with a cutoff of 14 Hz, the high-power P- and T-waves are filtered with a cutoff frequency in the range of 20–30 Hz, and the high-frequency QRS complexes are filtered with cutoff frequency of higher than 100 Hz. The suggested dynamic filter satisfies the conflicting requirements for a strong suppression of EMG noise and at the same time a maximal preservation of the ECG high-frequency components.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Bortolan G, Christov I (2014) Dynamic filtration of high-frequency noise in ECG signal. Comput Cardiol 41:1089–1092

    Google Scholar 

  2. Bortolan G, Christov I, Simova I, Dotsinsky I (2015) Noise processing in exercise ECG stress test for the analysis and the clinical characterization of QRS and T wave alternans. Biomed Sign Process Control 18:378–385. doi:10.1016/j.bspc.2015.02.003

    Article  Google Scholar 

  3. Christov II, Daskalov IK (1999) Filtering of electromyogram artifacts from the electrocardiogram. Med Eng Phys 21(10):731–736

    Article  CAS  PubMed  Google Scholar 

  4. Dotsinsky I, Christov I, Daskalov I (1996) Assessment of metrological characteristics of digital electrocardiographs. J Clin Eng 21:156–160

    Article  Google Scholar 

  5. Dotsinsky I, Mihov J (2008) Tremor suppression in ECG. Biomed Eng Online 7:29. https://biomedical-engineering-online.biomedcentral.com/articles/10.1186/1475-925X-7-29

  6. European Conformance Testing Services for Computerizes Electrocardiography (2005) CTS ECG test atlas. Institute for Biosignal Processing and System Analysis, Garching

  7. García-Niebla J, Serra-Autonell G (2009) Effects of inadequate low-pass filter application. J Electrocardiol 42(4):303–304

    Article  PubMed  Google Scholar 

  8. Gotchev A, Christov I, Egiazarian K (2002) Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method. In: International conference on acoustics, speech and signal processing (ICASSP2002), Orlando, FL, USA, 13–17 May, pp 3872–3875

  9. Joy J, Manimegalai P (2013) Wavelet based EMG artifact removal from ECG signal. J Eng Comp Appl Sci 2(8):55–58

    Google Scholar 

  10. Kligfield P, Gettes LS, Bailey JJ et al (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol 49:1109–1127

    Article  PubMed  Google Scholar 

  11. Kligfield P, Okin PM (2007) Prevalence and clinical implications of improper filter settings in routine electrocardiography. Am J Cardiol 99:711–713

    Article  PubMed  Google Scholar 

  12. Nakagawa M, Tsunemitsu C, Katoh S et al (2014) Effect of ECG filter settings on J-waves. J Electrocardiol 47(1):7–11

    Article  PubMed  Google Scholar 

  13. Savitzky A, Golay M (1964) Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 36:1627–1639

    Article  CAS  Google Scholar 

  14. Sayyad RA, Mundada K (2016) Enhancement and denoising of ECG signal using extended Kalman filter and extended Kalman smoother. J Innov Electron Commun Eng 6(1):22–26

    Google Scholar 

  15. Simova I, Christov I, Kambova L, Bortolan G, Katova T (2014) QRS and T loops area changes during haemodialysis. Comput Cardiol 41:409–412

    Google Scholar 

  16. Subcommittee on Instrumentation Committee on Electrocardiography—American Heart Association (1967) Recommendation for instruments in electrocardiography and vectorcardiography. IEEE Trans Biomed Eng 14:60–68

    Google Scholar 

  17. Tulyakova N (2017) Locally-adaptive Myriad filters for processing ECG signals in real time. Int J Bioautom 21(1):5–14

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ivaylo Christov.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Christov, I., Neycheva, T., Schmid, R. et al. Pseudo-real-time low-pass filter in ECG, self-adjustable to the frequency spectra of the waves. Med Biol Eng Comput 55, 1579–1588 (2017). https://doi.org/10.1007/s11517-017-1625-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-017-1625-y

Keywords

Navigation