Abstract
The electrocardiogram (ECG) acquisition is often accompanied by high-frequency electromyographic (EMG) noise. The noise is difficult to be filtered, due to considerable overlapping of its frequency spectrum to the frequency spectrum of the ECG. Today, filters must conform to the new guidelines (2007) for low-pass filtering in ECG with cutoffs of 150 Hz for adolescents and adults, and to 250 Hz for children. We are suggesting a pseudo-real-time low-pass filter, self-adjustable to the frequency spectra of the ECG waves. The filter is based on the approximation procedure of Savitzky–Golay with dynamic change in the cutoff frequency. The filter is implemented pseudo-real-time (real-time with a certain delay). An additional option is the automatic on/off triggering, depending on the presence/absence of EMG noise. The analysis of the proposed filter shows that the low-frequency components of the ECG (low-power P- and T-waves, PQ-, ST- and TP-segments) are filtered with a cutoff of 14 Hz, the high-power P- and T-waves are filtered with a cutoff frequency in the range of 20–30 Hz, and the high-frequency QRS complexes are filtered with cutoff frequency of higher than 100 Hz. The suggested dynamic filter satisfies the conflicting requirements for a strong suppression of EMG noise and at the same time a maximal preservation of the ECG high-frequency components.
Similar content being viewed by others
References
Bortolan G, Christov I (2014) Dynamic filtration of high-frequency noise in ECG signal. Comput Cardiol 41:1089–1092
Bortolan G, Christov I, Simova I, Dotsinsky I (2015) Noise processing in exercise ECG stress test for the analysis and the clinical characterization of QRS and T wave alternans. Biomed Sign Process Control 18:378–385. doi:10.1016/j.bspc.2015.02.003
Christov II, Daskalov IK (1999) Filtering of electromyogram artifacts from the electrocardiogram. Med Eng Phys 21(10):731–736
Dotsinsky I, Christov I, Daskalov I (1996) Assessment of metrological characteristics of digital electrocardiographs. J Clin Eng 21:156–160
Dotsinsky I, Mihov J (2008) Tremor suppression in ECG. Biomed Eng Online 7:29. https://biomedical-engineering-online.biomedcentral.com/articles/10.1186/1475-925X-7-29
European Conformance Testing Services for Computerizes Electrocardiography (2005) CTS ECG test atlas. Institute for Biosignal Processing and System Analysis, Garching
García-Niebla J, Serra-Autonell G (2009) Effects of inadequate low-pass filter application. J Electrocardiol 42(4):303–304
Gotchev A, Christov I, Egiazarian K (2002) Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method. In: International conference on acoustics, speech and signal processing (ICASSP2002), Orlando, FL, USA, 13–17 May, pp 3872–3875
Joy J, Manimegalai P (2013) Wavelet based EMG artifact removal from ECG signal. J Eng Comp Appl Sci 2(8):55–58
Kligfield P, Gettes LS, Bailey JJ et al (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society endorsed by the International Society for Computerized Electrocardiology. J Am Coll Cardiol 49:1109–1127
Kligfield P, Okin PM (2007) Prevalence and clinical implications of improper filter settings in routine electrocardiography. Am J Cardiol 99:711–713
Nakagawa M, Tsunemitsu C, Katoh S et al (2014) Effect of ECG filter settings on J-waves. J Electrocardiol 47(1):7–11
Savitzky A, Golay M (1964) Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 36:1627–1639
Sayyad RA, Mundada K (2016) Enhancement and denoising of ECG signal using extended Kalman filter and extended Kalman smoother. J Innov Electron Commun Eng 6(1):22–26
Simova I, Christov I, Kambova L, Bortolan G, Katova T (2014) QRS and T loops area changes during haemodialysis. Comput Cardiol 41:409–412
Subcommittee on Instrumentation Committee on Electrocardiography—American Heart Association (1967) Recommendation for instruments in electrocardiography and vectorcardiography. IEEE Trans Biomed Eng 14:60–68
Tulyakova N (2017) Locally-adaptive Myriad filters for processing ECG signals in real time. Int J Bioautom 21(1):5–14
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Christov, I., Neycheva, T., Schmid, R. et al. Pseudo-real-time low-pass filter in ECG, self-adjustable to the frequency spectra of the waves. Med Biol Eng Comput 55, 1579–1588 (2017). https://doi.org/10.1007/s11517-017-1625-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-017-1625-y