Computational wear assessment of hard on hard hip implants subject to physically demanding tasks

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loading at the hip joint, resulting in generation of wear and related debris. Estimation of wear under the above gait activities is thus crucial to design and develop a new and improved implant component. With this motivation, this paper presents an assessment of wear generation of PCD-on-PCD (poly crystalline diamond) hip implants using finite element (FE) analysis. Three-dimensional (3D) FE model of hip implant along with peak gait and peak flexion angle for each activity was used to estimate wear of PCD for 10 million cycles. The maximum and minimum initial contact pressures of 206.19 MPa and 151.89 MPa were obtained for carrying load of 40 kg and sitting down or getting up activity. The simulation results obtained from finite element model also revealed that the maximum linear wear of 0.585 μm occurred for the patients frequently involved in sitting down or getting up gait activity and maximum volumetric wear of 0.025 mm3 for ladder up gait activity. The stair down activity showed the least linear and volumetric wear of 0.158 μm and 0.008 mm3, respectively, at the end of 10 million cycles.

Computational wear assessment of hip implants subjected to physically demanding tasks

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Amstutz HC (2000) Precision hip joint replacement method. Google patents

  2. Gallo J, Vaculova J, Goodman SB, Konttinen YT, Thyssen JP (2014) Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement. Acta Biomater 10(6):2354–2366

    Article  PubMed  PubMed Central  Google Scholar 

  3. Saikko VO (1993) Wear of polyethylene acetabular cups against alumina femoral heads: 5 prostheses compared in a hip simulator for 35 million walking cycles. Acta Orthop 64(5):507–512

    Article  CAS  Google Scholar 

  4. Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN (2009) Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 “HAP” PAUL Award. J Arthroplast 24(1):110–116

    Article  Google Scholar 

  5. Walter WL, O'toole GC, Walter WK, Ellis A, Zicat BA (2007) Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplast 22(4):496–503

    Article  Google Scholar 

  6. MacDonald SJ, Brodner W, Jacobs JJ (2004) A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplast 19(8):12–16

    Article  Google Scholar 

  7. Bragdon CR, Doerner M, Martell J, Jarrett B, Palm H, Malchau H et al (2013) The 2012 John Charnley Award: clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA. Clin Orthop Relat Res 471(2):393–402

    Article  PubMed  Google Scholar 

  8. Chen Y, Zhang L, Arsecularatne J, Montross C (2006) Polishing of polycrystalline diamond by the technique of dynamic friction, part 1: prediction of the interface temperature rise. Int J Mach Tools Manuf 46(6):580–587

    Article  Google Scholar 

  9. Pope BJ, Taylor JK, Dixon RH, Gardinier CF, Pope LM, Blackburn DC, et al. (2004) Prosthetic hip joint having a polycrystalline diamond articulation surface and a plurality of substrate layers. Google patents

  10. Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J et al (2001) Hip contact forces and gait patterns from routine activities. J Biomech 34(7):859–871

    Article  CAS  PubMed  Google Scholar 

  11. Varady PA, Glitsch U, Augat P (2015) Loads in the hip joint during physically demanding occupational tasks: a motion analysis study. J Biomech 48(12):3227–3233

    Article  PubMed  Google Scholar 

  12. Liu F, Jin Z, Roberts P, Grigoris P (2006) Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. Proc Inst Mech Eng H J Eng Med 220(6):695–704

    Article  Google Scholar 

  13. Yoshida H, Faust A, Wilckens J, Kitagawa M, Fetto J, Chao EY-S (2006) Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living. J Biomech 39(11):1996–2004

    Article  CAS  PubMed  Google Scholar 

  14. Shankar S, Nithyaprakash R (2014) Effect of radial clearance on wear and contact pressure of hard-on-hard hip prostheses using finite element concepts. Tribol Trans 57(5):814–820

    Article  CAS  Google Scholar 

  15. Quental C, Folgado J, Fernandes PR, Monteiro J (2015) Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses. Med Biol Eng Comput 53(2):111–122

    Article  CAS  PubMed  Google Scholar 

  16. Uddin M, Zhang L (2013) Predicting the wear of hard-on-hard hip joint prostheses. Wear 301(1):192–200

    Article  CAS  Google Scholar 

  17. Shankar S, Gowthaman K, Uddin M (2015) Predicting long-term wear performance of hard-on-hard bearing couples: effect of cup orientation. Med Biol Eng Comput 54(10):1541–1552

    Article  PubMed  Google Scholar 

  18. Kang L, Galvin A, Jin Z, Fisher J (2006) A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Proc Inst Mech Eng H J Eng Med 220(1):33–46

    Article  CAS  Google Scholar 

  19. Zietz C, Fabry C, Baum F, Bader R, and Kluess D (2015) The divergence of wear propagation and stress at steep acetabular cup positions using ceramic heads and sequentially cross-linked polyethylene liners. J Arthroplasty 30(8):1458–1463

  20. Uddin M (2015) Contact of dual mobility implants: effects of cup wear and inclination. Comput Methods Biomech Biomed Eng 18(15):1611–1621

    Article  CAS  Google Scholar 

  21. Barreto S, Folgado J, Fernandes PR, Monteiro J (2010) The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis. J Biomech Eng 132(5):054503

    Article  PubMed  Google Scholar 

  22. Marshek K, Chen H (1989) Discretization pressure-wear theory for bodies in sliding contact. J Tribol 111(1):95–100

    Article  Google Scholar 

  23. Shankar S, Nithyaprakash R (2015) Predicting the wear of soft-on-hard bearing couples for human hip prosthesis using finite element concepts. J Mech Med Biol 16(3):1650020

    Article  Google Scholar 

  24. Queiroz R, Oliveira A, Trigo F, Lopes J (2013) A finite element method approach to compare the wear of acetabular cups in polyethylene according to their lateral tilt in relation to the coronal plane. Wear 298:8–13

    Article  Google Scholar 

  25. Shankar S, Nithyaprakash R (2014) Wear prediction on silicon nitride bearing couple in human hip prosthesis using finite element concepts. Proc Inst Mech Eng J J Eng Tribol 228(7):717–724

    Article  CAS  Google Scholar 

  26. Harding D, Blackburn D, Loesener G, Dixon R, & Nguyen B (2011) Wear rate comparison between polycrystalline diamond, CoCr, and UHMWPE in high wear environments. In: International Society for Advanced Spine Surgery (ISASS) conference (pp. 28–29)

  27. Harun MN, Wang F, Jin Z, Fisher J (2009) Long-term contact-coupled wear prediction for metal-on-metal total hip joint replacement. Proc Inst Mech Eng J J Eng Tribol 223(7):993–1001

    Article  Google Scholar 

  28. Liu F, Leslie I, Williams S, Fisher J, Jin Z (2008) Development of computational wear simulation of metal-on-metal hip resurfacing replacements. J Biomech 41(3):686–694

    Article  CAS  PubMed  Google Scholar 

  29. Al-Hajjar M, Fisher J, Tipper JL, Williams S, Jennings LM (2013) Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions. Proc Inst Mech Eng H J Eng Med 227(5):535–542

    Article  Google Scholar 

  30. Karbach L, Matthies A, Ismaily S, Gold J, Hart A, Chan N et al (2013) Which patient activities generate edge wear of hip resurfacing arthroplasties? Bone Joint J 95(SUPP 34):26–26

    Google Scholar 

  31. Fabry C, Herrmann S, Kaehler M, Klinkenberg E-D, Woernle C, Bader R (2013) Generation of physiological parameter sets for hip joint motions and loads during daily life activities for application in wear simulators of the artificial hip joint. Med Eng Phys 35(1):131–139

    Article  PubMed  Google Scholar 

  32. Affatato S, Spinelli M, Zavalloni M, Mazzega-Fabbro C, Viceconti M (2008) Tribology and total hip joint replacement: current concepts in mechanical simulation. Med Eng Phys 30(10):1305–1317

    Article  CAS  PubMed  Google Scholar 

  33. Mellon S, Kwon Y-M, Glyn-Jones S, Murray D, Gill H (2011) The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing. Med Eng Phys 33(10):1212–1220

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Nithyaprakash.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants performed by any of the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nithyaprakash, R., Shankar, S. & Uddin, M.S. Computational wear assessment of hard on hard hip implants subject to physically demanding tasks. Med Biol Eng Comput 56, 899–910 (2018). https://doi.org/10.1007/s11517-017-1739-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-017-1739-2

Keywords

Navigation