Abstract

Purpose

Non-invasive imaging assessment of cardiac function is important in cardiovascular disease diagnosis, especially for evaluation of local cardiac motion. Tagged cardiac MRI has been developed for this purpose, but evaluation of the results requires quantification and automation.

Methods

Two methods utilizing active contour modeling for wall motion extraction based on tagged cardiac MRI scans were evaluated based on properties of tracking methods in the image domain and frequency domain. Three criteria were used: accuracy, inter-subject and intra-subject sensitivity. The tracking results were evaluated by a medical expert. The evaluation methodology and its possible generalization to other diagnostic methods were considered.

Results

Image domain and frequency domain analysis of tagged cardiac MRI data sets were evaluated demonstrating that the image domain method provides better results. The image domain method method is much more resistant to changes in the data, this time, due to a different subject being scanned. The frequency domain approach is not suitable for clinical applications, as the global error is significantly increased (more than 20%).

Conclusion

The image domain method was found most effective, and it can generate a set of clearly identified parameters. The evaluation approach can be an interesting alternative to classical psychovisual studies which are time-consuming and often fastidious for clinicians.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zerhouni E, Parish D, Rogers W, Yang A, Shapiro E (1988) Human heart : tagging with MR imaging—a method for noninvasive assessment of myocardial motion. Radiology 169(1): 59–63

    PubMed  CAS  Google Scholar 

  2. Axel L, Dougherty L (1989) MR imaging of motion with spatial modulation of magnetization. Radiology 172(2): 349–350

    PubMed  CAS  Google Scholar 

  3. Axel L, Dougherty L (1989) Improved method of spatial modulation of magnetization (spamm) for MRI of heart wall motion. Radiology 172: 349–350

    PubMed  CAS  Google Scholar 

  4. Prince JL, McVeigh E (1992) Motion estimation from tagged MR image sequences. IEEE Trans Med Imaging 11(2): 238–249

    Article  PubMed  CAS  Google Scholar 

  5. Kumar S, Goldgof D (1994) Automatic tracking of SPAMM grid and the estimation of deformation parameters from cardiac MR images. IEEE Trans Med Imaging 13(1): 122–132

    Article  PubMed  CAS  Google Scholar 

  6. Gupta S, Prince J (1995) On variable brightness optical flow for tagged MRI. In: Kluwer (ed) Information processing in medical imaging. Kluwer, Dordrecht (Pays-Bas), pp 323–334

  7. Kraitchman D, Young A, Chang C, Axel L (1995) Semi-automatic tracking of myocardial motion in MR tagged images. IEEE Trans Med Imaging 14(3): 422–433

    Article  PubMed  CAS  Google Scholar 

  8. Young AA, Kraitchmann DL, Dougherty L, Axel L (1995) Tracking an finite element analysis of stripe deformation in magnetic resonance tagging. IEEE Trans Med Imaging 14(3): 413–421

    Article  PubMed  CAS  Google Scholar 

  9. Zhang S, Douglas M, Yaroslavsky L, Summers R, Dilsizian V, Fananapazir L, Bacharach S (1996) A fourier based algorithm for tracking SPAMM tags in gated magnetic resonance cardiac images. Medi Phy 32(8): 1359–1369

    Article  Google Scholar 

  10. Gupta S, Prince J, Androutsellis-Theotokis S (1997) Bandpass optical flow for tagged MRI. In: International conference on image processing, vol 3. San Diego, CA, pp 364–367

  11. Guttman M, Zerhouni E, McVeigh E (1997) Analysis of cardiac function from MR images. IEEE Comput Graph Appl 17(1): 30–38

    Article  PubMed  Google Scholar 

  12. Radeva P, Amini A, Huang J (1997) Deformable B-solids and implicit snakes for 3D localization and tracking of SPAMM MRI data. Comput Vis Image Underst 66: 163–178

    Article  Google Scholar 

  13. Amini AA, Chen Y, Curwen RW, Mani V, Sun J (1998) Coupled B-snake grids and constrained thin-plate splines for analysis of 2D tissue deformations from tagged MRI. IEEE Trans Med Imaging 17(3): 344–356

    Article  PubMed  CAS  Google Scholar 

  14. Denney T (1999) Estimation and detection of myocardial tags in MR images without user-defined myocardial contours. IEEE Trans Med Imaging 18(4): 330–344

    Article  PubMed  Google Scholar 

  15. Dougherty L, Asmuth J, Blom A, Axel L, Kumar R (1999) Validation of an optical flow method for tag displacement estimation. IEEE Trans Med Imaging 18(4): 359–363

    Article  PubMed  CAS  Google Scholar 

  16. Groot-Koerkamp M, Snoep G, Muijtjens A, Kemerink G (1999) Improving contrast and tracking of tags in cardiac magnetic resonance images. Magn Reson Med 41: 973–982

    Article  Google Scholar 

  17. Osman NF, Mc Veigh ER, Prince JL (2000) Imaging heart motion using Harmonic Phased MRI (HARP). IEEE Trans Med Imaging 19: 186–202

    Article  PubMed  CAS  Google Scholar 

  18. Urayama S, Matsuda T, Sugimoto N, Mizuta S, Yamada N, Uyama C (2000) Detailed motion analysis of the left ventricular myocardium using an MR tagging method with a dense grid. Magn Reson Med 44(1): 73–82

    Article  PubMed  CAS  Google Scholar 

  19. Clarysse P, Bracoud L, Croisille P, Magnin IE (2001) Integrated quantitative analysis of tagged magnetic resonance images. FIMH-LNCS 2230: 69–75

    Google Scholar 

  20. Haber I, Kikinis R, Westin CF (2001) Phase-driven finite elements model for spatio-temporal tracking in tagged mri. In: Proceedings of fourth international conference on medical image computing and computer assisted intervention (MICCAI’01), pp 1352– 1353

  21. Chandrashekara R, Mohiaddin RH, Rueckert D (2002) Analysis of myocardial motion in tagged MR images using nonrigid image registration. In: Medical image understanding and analysis, porthmouth

  22. Petitjean C, Rougon N, Prêteux F, Cluzel Ph, Grenier Ph (2003) A non rigid registration approach for measuring myocardial contraction in tagged mri using exclusive f-information. In: Proceedings international conference on image and signal processing (ICISP’2003). Agadir, Morocco, pp 25–27

  23. Rougon N, Petitjean C, Prêteux F, cluzek P, Grenier P (2005) A non-rigid registration approach for quantifying myocardial contraction in tagged MRI using generalized information measures. Med Image Anal 9: 353–375

    Article  PubMed  Google Scholar 

  24. Oubel E, De Craene M, Gazzola M, Hero AO, Frangi AF (2007) Multiview registration of cardiac tagging mri images. In: Biomedical imaging: from Nano to Macro, 2007. ISBI 2007. 4th IEEE international symposium on, pp 388–391

  25. Axel L, Sohae C, Ting C (2007) Tagged mri analysis using Gabor filters. In: Biomedical imaging: from Nano to Macro, 2007. ISBI 2007. 4th IEEE international symposium on, pp 684–687

  26. Histace A, Cavaro-Ménard C, Courboulay V, Ménard M (June 2005) Analysis of tagged cardiac MRI sequences. Lecture notes on computer science (proceedings of the 3rd functional imaging and modelling of the heart (FIMH) workshop), vol 3504, pp 404–413

  27. Histace A, Ménard M, Cavaro-Ménard C (2009) Selective diffusion for oriented pattern extraction: application to tagged cardiac MRI enhancement. Pattern Recognit Lett 30(15): 1356–1365

    Article  Google Scholar 

  28. Histace A, Hermand L, Cavaro-Ménard C (June 2002) Tagged cardiac MR images analysis. In: Biosignal 2002, pp 313–315

  29. Histace A, Matuszewski B, Zhang Y (2009) Segmentation of myocardial boundaries in tagged cardiac mri using active contours: a gradient-based approach integrating texture analysis. Int J Biomed Imaging 2009, 8

  30. Goodman CS (1998) Introduction to health care technology assessment. National Library Medecine/NICHSR, USA

    Google Scholar 

  31. Jannin P, Fitzpatrick JM, Hawkes DJ, Pennec X, Shahidi R, Vannier MW (2002) Validation of medical image processing in image-guided therapy. IEEE Trans Med Imaging 21(12): 1445–1449

    Article  PubMed  Google Scholar 

  32. Neizel M, Lossnitzer D, Korosoglou G, Schaufle T, Peykarjou H, Steen H, Ocklenburg C, Giannitsis E, Katus HA, Osman NF (2009) Strain-encoded MRI for evaluation of left ventricular function and transmurality in acute myocardial infarction. Circ Cardiovasc Imaging 2(2): 116–122

    Article  PubMed  Google Scholar 

  33. Korosoglou G, Lossnitzer D, Schellberg D, Lewien A, Wochele A, Schaeufele T, Neizel M, Steen H, Giannitsis E, Katus HA, Osman NF (2009) Strain-encoded cardiac MRI as an adjunct for dobutamine stress testing: incremental value to conventional wall motion analysis. Circ Cardiovasc Imaging 2(2): 132–140

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aymeric Histace.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Histace, A., Portefaix, C. & Matuszewski, B. Comparison of different grid of tags detection methods in tagged cardiac MR imaging. Int J CARS 6, 153–161 (2011). https://doi.org/10.1007/s11548-010-0495-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11548-010-0495-7

Keywords

Navigation